APPLICATIONS 

 

 

The 

Apollo 

Model 7000ETL Slide Gate Operator is designed to handle a slide gate 

up to 22 feet in total length (accomodates a 20 foot drive) and 600 Lbs. A 
professional fence or gate dealer is recommended to assure proper installation. 

Apollo Gate Operators

 are available only through qualified dealers with an 

outstanding reputation in the fence and gate industry. These dealers will be able to 
recommend the proper equipment for particular applications. 

Apollo Gate 

Operators 

are 12 Volt DC (

Direct Current

) powered. A 12 Volt 33 ampere hour 

(minimum) sealed battery is recommended. There are several advantages with 12 
Volt DC systems: 
 

• 

Low voltage virtually eliminates risk of electrical shock. 

• 

Battery powered operators can provide up to 200 operations in the event of 
power outages. 

• 

The battery may be recharged with a trickle charger or by solar energy  
(Electrical battery chargers should have a class 2 transformer rating).  

 

If a trickle charger is used and a standard electrical outlet is not readily available, a 
licensed electrician will be required for proper electrical hook up. 
 
The following table should be used as a guide for capacity of operation of operators 
only, additional options may reduce the the daily usage. 

Please note that the charge 

capability of solar panels will vary with different geographical locations.  
 

                              Daily Cycles       

1-10  1-20  1-40  1-60  1-80  80+ 

5 watt solar panel 

 

 

 

 

 

10 watt solar panel 

 *        

20 watt solar panel 

(requires 5310 regulator) 

 

 

 

 

 

30 watt solar panel 

(requires 5310 regulator) 

   *   

40 watt solar panel 

(requires 5310 regulator) 

 

 

 

 

 

1.5 amp battery charger 

    *  

10 amp battery charger 

 

 

 

 

 

Note: Double the amount of solar panels for Dual Gate Operators. 

Summary of Contents for 7000ETL

Page 1: ...Model 7000ETL INSTALLATION MANUAL APOLLO Gate Operators Inc Post Mounted Residential Medium Duty Commercial Slide Gate Operator 04 07...

Page 2: ...ation 6 Operator Installation 7 Chain Bracket Installation 8 Chain Chain Bolt Installation 8 9 Chain Magnets Installation 9 Gate Limit Switch Installation 10 Quick Release Operation 10 Programming Cur...

Page 3: ...rgency access Use the emergency release only when the gate is not moving A secondary entrapment device such as loop detectors edge switches and beam detectors are highly recommended and required to me...

Page 4: ...can provide up to 200 operations in the event of power outages The battery may be recharged with a trickle charger or by solar energy Electrical battery chargers should have a class 2 transformer rati...

Page 5: ...ine the general location of the operator chian brackets and solar panel if used 1 Is there a suitable location for the operator 2 Can the solar panel if used be mounted in an unobstructed area facing...

Page 6: ...n Links 2 each Operator 5 16 x 2 U Bolts 4 each Magnetic Chain Limits with hardware 2 each Chain Bolts with hardware 2 each 5 16 Washers Lock Washers Nuts 16 each 5 16 x 3 U Bolts 4 each 404C Automati...

Page 7: ...nside posts 6 STEP 2 Remove chain cover and front lid Mount to posts using the four supplied 3 U bolts STEP 1 Install two 3 dia Posts parallel to the gate as shown Posts height depends on height prefe...

Page 8: ...ate using the supplied 2 U bolts Do not tighten at this time STEP 4 Attach the chain to the chain bolt using the master chain link Adjust the chain bolt to allow for maximum tightening Note The height...

Page 9: ...required length of chain needed to attach to the chain bolt and still allow adjustment Using a chain breaking tool remove excess chain Attach chain to chain bolt Tighten all chain brackets and chain...

Page 10: ...Install chain cover Install solar panel or battery charger and any optional accessories Close box Good Job If the gate automatically opens when the Timer To Close is on rewire the bottom half of the c...

Page 11: ...ce All limits should be set before beginning this procedure This new procedure applies to revision 31 or higher firmware 1 Press and hold the LED ENABLE button for five seconds The STOP LED will blink...

Page 12: ...Indicators Optional Device Input Remote Monitor Outputs and Photo Eye GateLink Connector Microprocessor Timer To Close Dual Gate Delay Current Sensitivity Adjustments Program Switches 835 836 Control...

Page 13: ...835 836 board Connect the relay wires of the accessory as normal COM to GND NO to SAFETY 14 for a safety device When the gate operator begins opening comes off of the closed limits the MAS terminal wi...

Page 14: ...roubleshooting Hold the push button down for five seconds to put the board in program mode RESET Resets the microprocessor Returns processor to last known state OPERATE When depressed activates the ga...

Page 15: ...utton released 6 LOCK TYPE For 12V mechanical solenoid locks For 12V magnetic locks 12V for 4 seconds on open cycle 12V when on close limit 7 COAST ENABLE Gate will stop immediately when at Gate will...

Page 16: ...ion see program switch 5 for options OPEN Open input from a 3 button station see program switch 5 for options GND Supplied Battery Ground GND Supplied Battery Ground FREE EXIT Opens gate if closed sto...

Page 17: ...or on the Remote Monitor Output Connector block Connect the black wire to the GND connector on the Remote Monitor Output Connector block Red Black Set Program Switch 4 as preferred ON Upon activation...

Page 18: ...code switches for proper operation If power is taken directly from battery or connected as shown below receiver should be configured for 12VDC Multi Code Digi Code Allstar Lift Master black gray gray...

Page 19: ...improper power source or if damage was caused by fire flood or lightning The manufacturer will not be responsible for any labor charges incurred in the removal or replacement of defective parts In ca...

Reviews: