Apollo Sprayers PRECISION-5 Instruction Manual Download Page 4

Page 4

 

NOTICE

 

 

 

 

Tipping the spray gun causes the spray gun to clog. Dried spray material also clogs the pressure delivery 
tube and fittings. The spray gun does not function when clogging occurs. 

 

When not in use, be sure to disconnect the hose and place the spray gun into the Handi-Hold™ Docking 
Station on the turbine to avoid tipping. 

 

 

Improper installation of the ground plug can result in the risk of electrical shock. If repair or 
replacement of the plug or cord is necessary, do not connect the ground wire to either flat blade 
terminal. The wire with green insulation (with or without a yellow stripe) is the

 

grounding wire.

 

 

1. For any question regarding proper installation of the ground plug, consult a qualified (licensed 

or certified) electrician.

 

 

2. Do not modify the plug provided. If the plug does not fit the outlet, have the proper outlet 

installed by a qualified electrician.

 

 

3. This product is for use on a nominal 110-volt circuit and has a grounding plug that looks like 

the plug in Figure 2. Make sure that the product is connected to an outlet having the same 
configuration as the plug. Do not use adapters with this product.

 

 

4. If an extension cord is required, use only a three wire extension cord that has the same 

configuration as the unit cord, including the (round) ground terminal.   Make sure that the 
extension cord is plugged into a properly grounded receptacle.

 

 

5. When using an extension cord, be sure it is in good condition and heavy enough to meet the 

specifications in the chart below. If an extension cord is needed the following wire sizes must 
be used.

 

 

25’ cord (7.62m)…………………………............................ 10, 12, or 14 Gauge

 

50’ cord (15.24m)………………………………................... 10 or 12 Gauge

 

100’ cord (30.48m)…………  ……………………………...... 10 Gauge

 

 

Grounding instructions for all countries using a 2 pronged plug configuration. 

 

 

 
 

Figure 2

 

 

 

This product must be properly grounded. In the event of an electrical short circuit, grounding reduces

 

the risk of electrical shock by providing an alternate path for the electrical current.

 

 

This product is equipped with a cord that has a ground wire and an appropriate ground plug. Plug the unit into an outlet that 

is properly installed and grounded in accordance with local codes and ordinances.

 

 

Safety Note: Users in countries in continental Europe and Australia and anywhere that offers a two pronged plug must be 

aware that this configuration does not provide grounding.

 

Summary of Contents for PRECISION-5

Page 1: ...ApolloSprayers PRECISION 5 Turbine Instruction Manual...

Page 2: ...Your Coatings 7 4 1 Coating Properties 7 4 2 Your Choice of Coatings and Viscosity 8 4 3 Technique 10 5 Using Pressure Pots With Turbine Systems 11 5 1 Testing Air Pressure In Pressure Pot 12 5 2 Clea...

Page 3: ...materials may be harmful if inhaled causing severe nausea fainting or poisoning Make sure the room is well ventilated Avoid all ignition sources such as static electricity sparks open flames hot objec...

Page 4: ...he same configuration as the plug Do not use adapters with this product 4 If an extension cord is required use only a three wire extension cord that has the same configuration as the unit cord includi...

Page 5: ...me Low Pressure HVLP air The air hose connects the turbine unit to the spray gun Air flows through the hose to the nozzle of the specially designed TrueHVLP spray gun Atomization of the coating is ach...

Page 6: ...time you have before catalyst hardener begins to set up 2 5 Get To Know Your Turbine Handi Hold Spray Gun Docking Station Every Precision 5 turbine comes equipped with the Handi Hold Spray Gun Docking...

Page 7: ...onal features a filter warning system an hour meter and IDLE MODE The filter warning system works to help prevent overheating your motor To prevent damage to the motor the turbine will shut itself dow...

Page 8: ...as 10 to as much as 50 depending on the model turbine you are using and the quality of the paint used Second it is necessary to use a larger nozzle and needle set in the spray gun 2 0mm or 2 5mm It is...

Page 9: ...50 Sanding Sealer 20 30 Enamels 20 40 Stains use from can Acrylic Enamel 50 60 Catalyzed Polyurethane 10 30 Polyurethane s Varnishes 20 30 Waterborne Coatings 00 10 Latex Emulsion Paint 10 40 Note Cha...

Page 10: ...ou have overlapped too wide If you have heavy or wet spots you have overlapped too much or sprayed too slowly 6 When spraying a large or pre assembled piece start at the top and work down 7 Try to spr...

Page 11: ...e fluid from the pot to the spray gun tip nozzle In general 5PSI 0 345 Bar of air pressure is adequate to push most average viscosity fluids to the spray gun nozzle Higher pressure would only be neces...

Page 12: ...trigger is pulled causing material to stream from the spray gun Always ensure that the remote pot is tightly sealed and all gaskets are in good shape to prevent air and fluid leaks Be sure to flush an...

Page 13: ...se Total Hours Turbine Recommended Maintenance Clean and or change pre filters and or cartridge filters every 50 hours or when necessary See Accessories Page for appropriate filter replacement for you...

Page 14: ...to the motor resulting in premature motor failure and voiding your warranty 8 1 Pre Filter Maintenance We recommend that you remove your pre filters after each use To remove the pre filters push your...

Page 15: ...d them up to a light similar to your car air intake filter If you cannot see light through more than 50 of the filter replace filter element NOTICE Filter element may be damaged if more than 50 PSI of...

Page 16: ...e affected To install a Y connector follow these instructions 1 Unscrew the female quick connect from the air outlet located on the side of your turbine 2 Screw on the Y connector Make sure the Y is s...

Page 17: ...10 Model 4500 July 1 2010 15 Page 17...

Page 18: ...ed 4 6 A9016 Rubber Foot 4 7 A4998 Pressure Regulator 1 8 A4503 1 8 Male NPT X 1 4 Male Hose Barb 90 1 9 A4033 Air Line Hose Clip S S 2 10 A2116 1 4 Air Hose Per Foot 3 11 A2119 1 4 X 1 4 Female Swive...

Page 19: ...Page 19 11 Model 4550 July 1 2010 32 WIRING DIAGRAM MODEL4550 6...

Page 20: ...4 A4503 1 8 Male NPT X 1 4 Male Hose Barb 90 1 15 A4033 Air Hose Clip S S 2 16 A2116 1 4 Air Hose Per Foot 3 17 A2119 1 4 X 1 4 Female Swivel Barb 1 18 A4026 Quick Connect Female With 1 4 Male Thread...

Page 21: ...cellent in the shop or on site Perfect for larger jobs when a quart liter is just not enough or when greater spray gun mobility is needed to get into a tight corner 2 5 gallon 10 liter pressure pot no...

Page 22: ...ers A2059 20 6m x 1 4 6mm fluid hose with couplers A2060 40 12m x 1 4 6mm fluid hose with couplers A2114 6 2m x 3 8 10mm fluid hose with couplers A2159 20 6m x 3 8 10mm fluid hose with couplers A2160...

Page 23: ...art 1 Liter Cup Assembly A5269 8oz 250ml Cup Assembly A5033A non teflon 250cc cup assembly A5033AT teflon 250cc cup assembly A5034A non teflon 600cc cup assembly A5034AT Teflon 600cc cup assembly A753...

Page 24: ...ncluding but not limited to implied Warranties of merchantability or fitness is excluded to the maximum extent permitted by law and if not excludable is limited to the duration of the express Warranty...