5.4.10  DATA CAPTURE 

The Data Capture display provides the facility to capture and display up to four selected words that are being  received 
from the incoming TDM PCM data stream.  Figure 18 shows what this display looks like. 

   F1

   F2

   F3

   F4

   F5

 

Figure 18:  DATA CAPTURE Screen 

The Word number (Word #

n

) is input on the display. The data capture field (Cap #

n

) displays what word is received in 

that word location (in hexadecimal format). The Word #

n

 is entered in decimal format. 

 

Table 11:  Selectable Definitions of the actions field on the Presets display

 

Field 

Definition 

Word # 1 through 4 

The  operator  enters  the  Word  number  to  capture  from  the  PCM  data  stream.    This  value  is 
programmable from 1 to 4096 decimal. 

Cap # 1 through 4 

Displays the captured data value in hexadecimal format. 

Function Keys

 

 

F1 

Go directly to Measurements display 

F2 

Go directly to the Edit PCM display 

F3 

Go directly to the Edit PCM display 

F4 

Go directly to Output Settings display 

F5 

Go directly to Presets display 

 

 

Summary of Contents for 2349 DLTM4

Page 1: ...ATA LINK TEST SET PRODUCT LINE MODEL 2349 DLTM4 APOGEE LABS INC i 09 21 2017 210 South 3rd Street North Wales PA 19454 Tel 215 699 2060 Fax 215 699 2061 INSTRUCTIONS For MODEL 2349 DLTM4 DATA LINK TES...

Page 2: ...This page left intentionally blank...

Page 3: ...TINGS 8 5 4 3 Input SETTINGS 11 5 4 5 PRN SETTINGS 12 5 4 6 PCM SETTINGS 13 5 4 7 EDIT PCM 14 5 4 8 DATA LOG SETUP 15 5 4 9 PRESETS 16 5 4 10 Data capture 17 5 5 REMOTE COMMANDS 18 5 5 1 SET 18 5 5 2...

Page 4: ...210 South 3rd Street North Wales PA 19454 Tel 215 699 2060 Fax 215 699 2061 iv 10 31 2012 APOGEE LABS INC...

Page 5: ...DATA CAPTURE Screen 17 Figure 19 Typical Telemetry Data Link Block Diagram 21 Figure 20 DLTM Transmitter Block Diagram 23 Figure 21 Basic Setup for Measuring Link Delay 25 TABLE OF TABLES Table 1 Jum...

Page 6: ......

Page 7: ...interface modules at the system level 3 FUNCTIONAL DESCRIPTION The transmitter and receiver contain independent circuits to generate test data and to receive and detect errors using either pseudo rand...

Page 8: ...t Based Intervals 10 to 1012 bits MEASUREMENTS Received Bit Rate Bit Count Receiver Re Syncs slips Bit Error Count Ones in Error Bit Error Rate Bit Slip Probability Symmetry Frames in Error Seconds in...

Page 9: ...the card slot at the far right side of the multiplexing cards facing the rear of the chassis Module position has an effect on front panel and remote control operations When the PAGE NEXT PREV keys are...

Page 10: ...t the desired value of shunt resistance Table 1 defines the resulting shunt resistance for given jumper configurations Figure 2 indicates the location of each jumper Table 1 Jumper Configuration Signa...

Page 11: ...LOCK RS 422 IN J5 TX DATA TTL OUT J6 TX CLOCK TTL OUT J7 RX DATA TTL IN J8 RX CLOCK TTL IN J9 System Time ST TTL IN J10 BiP DATA BIPOLAR OUT J11 TIME IRIG B IN Direction is in reference to the DLTM4 O...

Page 12: ...sented here To change from one module to another module within the AL6301 chassis press the NEXT or PREV buttons on the top right of the display This will display the next or previous module in the ch...

Page 13: ...actions Table 3 Selectable Definitions of the actions field on the Status Screen Selectable Function Definition Insert Error Invert a single bit in the output bit stream Insert Slip Cause a bit slip r...

Page 14: ...te up to 50Mbps At higher rates careful attention must be payed to cabling and termination Type Selects the output data source as PRN or PCM data Code NRZ L NRZ M NRZ S BiP L BiP M BiP S RNRZ 15 DM M...

Page 15: ...ermitting the blanking function to force bits to zero This value is programmable from 64 to 1024 Blank Defines the number of bits after NON BLANK that are to be forced to zero This value is programmab...

Page 16: ...OCK TTL POS CLOCK RS 422 signals A red B blue NEG CLOCK RS 422 signals A red B blue Figure 10 CLOCK POLARITY SETTINGS POS TTL DATA NEG TTL DATA DIGITAL VALUE 0 1 0 1 POS DATA RS 422 signals A red B bl...

Page 17: ...inition Interface TTL RS422 LOOPB RX Code This field is used to select the bit code that is applied to the receiver The selectable codes are NRZ L NRZ M NRZ S BiP L BiP M BiP S DM M DM S RX Polarity c...

Page 18: ...able describes the fields from the PRN Setting display Table 6 Selectable Definitions of the actions field on the PRN Settings display Field Definition Pattern Select the pseudo random data sequence P...

Page 19: ...he DLTM4 whether to output the PCM data or not this must be set to RUN for the PCM to be output Frame Structure General Word This defines the General Word which is a word that can be defined for inclu...

Page 20: ...orresponds to the instruction to the left of it Any values placed that exceed the frame length ate ignored Table 8 Selectable Definitions of the actions field on the EDIT PCM display Instruction Defin...

Page 21: ...efinition Log Type This field is set by the user to select the data logging mode Three selections are offered None Interval and On Change Selecting None disables the Data Log process The Interval mode...

Page 22: ...ading process The message Ready indicates that the process is idle and awaiting an operator action Saving indicates that the current program is being saved as a result of the operator pressing F1 Afte...

Page 23: ...the display The data capture field Cap n displays what word is received in that word location in hexadecimal format The Word n is entered in decimal format Table 11 Selectable Definitions of the actio...

Page 24: ...odule 5 5 5 SAVE LOAD The SAVE command saves the current settings to the preset group number specified by the PRESET number The LOAD command retrieves and replaces the current program with the setting...

Page 25: ...r Reverse form of the selected PRN sequence Figure 13 INSERT TIME Turns on or off the insert time IRIG into the PRN stream Set to either ON or OFF Figure 13 FIRST TX Set the first bit transmitted to M...

Page 26: ...rate Figure 8 BSP Read Only Reports the Bit Slip Probability Figure 8 FRM ERR Read Only Reports the number of Frames containing errors Figure 8 ERR SEC Read Only Reports the number of Seconds contain...

Page 27: ...devices can benefit from using more than a simple bit error rate tester This note identifies several unique requirements that the AL6300 Data Link Test Set addresses 6 1 1 I Q CHANNELS Multiple DLTM4...

Page 28: ...t this kind of investigation With random errors the symmetry should show 50 with PRN data making the evaluation straightforward While displaying the number of bit errors and 1 s in error FREEZE the AL...

Page 29: ...SETUP A separate menu is provided that allows the PCM frame to be defined Sync Pattern Bits per Word all words in the frame are the same length Words per Frame MSB LSB first which direction the data i...

Page 30: ...er Frame 8 MSB LSB first MSB If set to LSB the bit stream is reversed EDIT PCM 1 LOAD IMM EEEE output the desired pattern set pc02 load imm set pv02 0xEEEE 2 REPEAT 7 fill out the PCM stream with all...

Page 31: ...inimum value of the counter to 0 CNT MAX FFFF Have the maximum value of the counter be 0xFFFF CNT INC DEC INC Start with 0 and increment until 0xFFFF then wrap around to 0 EDIT PCM 1 PC01 LOAD FSP PV0...

Page 32: ...serve the MEASURE screen and verify that the system is running and that it is passing error free data through the system If errors are present check the ERRORS screen to verify that No Errors are prog...

Page 33: ...traight line function Program the CYCLE TIME to the period in seconds that it is desired for the output bit rate to change from START to END values Set the OPERATION to SINGLE to generate single frequ...