Electrcal Connections: Timer model. (Diagram X2.)
Remove the internal cover by removing the 2 small caps and retaining philips
screws to access the terminal connections. The fan can either be operated
from a separate pullcord switch fitted to the ceiling of the room or can be
connected to the light switch so that the fan will start when the light is switched
on. A double pole fused spur having a contact separation of at least 3mm in all
poles must be used and fitted with a 3 amp fuse, and should be sited outside
any room containing a shower or fixed bath. The fan should not be accessible
to a person using either the shower or the bath.
Timer Adjustment
The Timer fan will run approximately one minute after it has been switched off.
This time delay can be increased by firstly switching off the power to the fan.
Remove the cover and the timer cover as detailed in diagram X2A. Insert a small
screwdriver into the slot, marked in
Diagram X2A,
and turn clockwise to
reduce the time and anti-clockwise to increase the time.
Only adjust with power
switched off.
the timer will run for is 20 seconds and the maximum is about 20
minutes
. NB Timer delay is adjustable as indicated on the timer strip cover.
8.
Electrical Connections: Electronic Humidity Model (Diagram 3)
For the fan to operate as a normal time delay unit with humidity over-ride i.e.
when connected with a switched live coming from the light switch into the fan,
the fan will operate when the light is switched on, and switch off after about 20
seconds to 20 minutes (timer is pre-set for the minimum). However should the
humidity in the room reach about 75%, which will happen if the shower is run or
the bath filled with hot water, the fan will switch on and keep running until the
humidity has been reduced to a normal level, about 65%. Connect to electrical
supply as shown in diagram 3
.
100mm Tile Fan, T. Max 40˚C Rated 220-240V ~50Hz 20W IP24
150mm Tile Fan, T. Max 40˚C Rated 220-240V ~50Hz 25W IP24
DIAGRAM X1
STANDARD MODEL
DIAGRAM X1A
SIDE VIEW
MAX
45min
1 min
MIN
RH%
40%
ON
90%
OFF
HUMIDITY OPERATED TIME DELAY CONTROL
The timer and humidity adjustments are as the normal instructions
Time Delay & humidity
over-ride operation
Terminal 1 - 1 Neutral Supply
Terminal 2 - 2 Switch live Supply
Terminal 3 - 3 Spare
Terminal 4 - 4 Permanet supply
Diagram 3
IMPORTANT
Switch off mains supply before making any electrical connections.
Installation must be supervised by a qualified electrician.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the applicance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other
open-fire appliances when mounted in outside windows or walls.
Fan must be disconnected from electrical power before any maintenance is carried out.
Fixing clip
Ceiling board
Screw
Fan
chassis
When screw is tightened fixing
clip fingers secure the fan