Apia CIMI line 16 User Manual Download Page 2

S A F E TY  IN S TR U C TIO N S  

1.

  Read this manual  

2.

  Heed all SAFETY INSTRUCTIONS as well as DANGER and OBLIGATION warnings

 

3.

  N ever  incorporate equipment or accessories not approved by APIA PRO AUDIO  

4.

  Read all the related PRODUCT INFORMATION documents before exploiting the system

 

The product information  document is included in the shipping carton of the related system component.

 

5.

  Read the  RIGGING MANUAL before installing the system

 

Use the rigging  accessories described  in the rigging manual

  and follow the associated procedures 

6.

  Beware of sound levels  

Do not stay within close proximity of loudspeakers in operation and consider wearing earplugs.

 

Loudspeaker systems are capable of producing very high sound pressure levels (SPL) which can instantaneously 

lead to permanent hearing damage to performers, production crew and audience members. Hearing damage can 

also occur with prolonged exposure to sound: 8 h at 90 dB(A), 30 min at 110 dB(A), less than 4 min at 130 dB(A).  

 

S Y M B O L S  

The following symbols are used in this document: 

 

DANGER  

This symbol indicates a potential risk of harm to an individual or damage to the product.

 

It can also notify the user about instructions that must be strictly followed to ensure safe installation or operation 

of the product. 

 

 

ELECTRICAL HAZARD

 

This symbol indicates a potential risk of electrical

  injury.

 

It can also notify the user about instructions that must be strictly followed to ensure safe installation or operation 

of the product. 

 

 

OBLIGATION  

This  symbol  noti es  the  user  about  instructions  that must  be  strictly followed  to  ensure  proper  installation

  or 

operation of the product. 

 

 

EQUIPMENT  

This symbol indicates the equipment, tools, and spare parts required to perform a procedure

 

 

INFORMATION

 

This symbol noti es the user about complementary information or optional instructions

 

 

ACTION  

This symbol indicates an action to perform. 

 
 

 

 

 
 

 

or

ion

ion

 

 

 

 

 

CIMI line 8/16

USER MANUAL

Summary of Contents for CIMI line 16

Page 1: ...CIMI line 8 16 USER MANUAL ...

Page 2: ...g damage can also occur with prolonged exposure tosound 8 h at 90 dB A 30min at 110 dB A less than 4 min at 130 dB A S YMB O L S The following symbols are used in this document DANGER This symbol indicates a potential risk of harmto an individual or damage to the product It can also notify the user about instructions that must be strictly followed to ensure safe installation or operation of the pr...

Page 3: ...VERAGE SWITCH 6 1 SUSPENDING F ROM THE F LY BAR 6 2 HANGING ON THE WALL 10 6 3 STANDING ON THE BASE 11 6 4 STANDING ON A C SUB SUBWOOFER 12 7 CIMILINE 8 SPECIFICATIONS 13 LAYOUT CIMILINE 16 LAYOUT 6 5 STANDING ON A C INFRASUBWOOFER 8 CIMILINE 16 SPECIFICATIONS 6 9 9 10 14 7 CIMI line 8 16 USERMANUAL 6 CONFIGURATIONS AND ACCESSORIES 3 ...

Page 4: ...nd horizontal con gurations for temporary or permanent installation For integration with other speakers or ampli ers the Cimiline 8 and Cimiline 16 o er selectable impedance 16Ω 64 Ω for the Cimiline 8and 8Ω 32 Ω for the Cimiline 16 Integrating powered C SUB and subwoofers ensures excellent coverage of the entire musical frequency range QDX 13ampli er series also features custom presets optimized ...

Page 5: ...4 PHYSICAL Weight 4 5 kg 9 9 lbs 4 1 CIMILINE 8 LAYOUT CIMI line 8 16 USER MANUAL 504 mm 70 mm 61 mm WEİGHT A4 SCALE cimiline 8 1 4 5 ...

Page 6: ...4 2 CIMILINE 16 LAYOUT Weight 8 kg 17 6 lbs CIMI line 8 16 USER MANUAL 1004 mm 70 mm 61 mm WEİGHT A4 SCALE cimiline 16 1 6 6 ...

Page 7: ...n parallel by the same ampli er channel 5 1 IMPEDANCE SWITC H Cimiline 8 and Cimiline 16 features a switch which allows users to select the impedance of the speaker Cimiline 8 16 64 Ω Cimiline 16 8 32 Ω The value to be selected depends mainly on the ampli er you use to drive the unit Impedance must be set to high 64 Ω for Cimiline 8 and 32Ω for Cimiline 16 when speakers are driven by C SUB and C I...

Page 8: ...ons to obtain maximum di usion with a minimum footprint Spot coverage sets a narrower vertical di usion angle and is recommended for long throw or monitoring application When more units are combined in a line array con guration make sure to set the coverage to Spot e g a r e v o C T O P S e g a r e v o C D O O L F 5 2 COVERAGE SWITC H e g a r e v o C T O P S e g a r e v o C D O O L F CIMILINE 8 CI...

Page 9: ... the main accessories available for this product 6 1 SUSPENDING F ROM THE F LY BAR Cimiline 8 and Cimiline 16 units can be suspended using the CM FLY bar accessory and the CM JOINThardware accessory used to connect together two units or to connect a unit to the y bar Mixed con guration with both Cimiline 8 and Cimiline 16 in the same cluster are also possible CIMI line 8 16 USER MANUAL CM FLY 9 ...

Page 10: ...SE accessory assists in standing up to 2 meters of Cimiline 8 Cimiline 16 For proper installation and operation connect the units to the base with CM FOOT and CM JOINT accessories Where possible screw the feet of the CM BASEto the ground CIMI line 8 16 USER MANUAL WALL V WALL H CM WALL H V CM WALL H V CM BASE 10 ...

Page 11: ...o meters of Cimiline 8 Cimiline 16 can be mounted on a C SUB subwoofer by using the CM FOOT and CM JOINTaccessories Acoustically speaking two Cimiline 16 perfectly match with a C SUB subwoofer C SUB 2 x CIMILINE 16 CIMI line 8 16 USER MANUAL 11 ...

Page 12: ...meters of Cimiline 8 Cimiline 16 can be mounted on a C INFRA subwoofer by using the CM FOOT and CM JOINTaccessories Acoustically speaking two Cimiline16 perfectly match with a C INFRA subwoofer C INFRA 2 x CIMILINE 16 CIMI line 8 16 USER MANUAL 12 ...

Page 13: ... Nominal dispersion angle V 7 30 selectable Nominal dispersion angle H 90 COMPONENTS 8 x 2 Neodymium magnet with 0 75 voice coil Ciwi Sub Ciwi Infra or QDX 13 amplifier network PHYSICAL DATA Connections 2 x NL4 or Finish ir green RAL 6009 Polyurea coating Cabinet Extruded aluminum Rigging CM BASE CM FLY CM FOOT CM JOINT CM WALL Protection Rating IP 45 Dimensions H x W x D 504 x 61 x 70 mm 19 8 x 2...

Page 14: ... Nominal dispersion angle V 7 30 selectable Nominal dispersion angle H 90 COMPONENTS 16 x 2 Neodymium magnet with 0 75 voice coil Ciwi Sub Ciwi Infra or QDX 13 amplifier network PHYSICAL DATA Connections 2 x NL4 or Finish Fir green RAL 6009 Polyurea coating Cabinet Extruded aluminum Rigging CM BASE CM FLY CM FOOT CM JOINT CM WALL Protection Rating IP 45 Dimensions H x W x D 1004 x 61 x 70 mm 39 5 ...