Precautions
WARNING! All wiring must be performed by a qualified electrician
or instrumentation engineer. See diagram for terminal designa-
tions and wiring examples. Consult factory for assistance.
WARNING! Avoid shock hazards! Turn signal input, output, and
power off before connecting or disconnecting wiring, or remov-
ing or installing module.
Précautions
ATTENTION! Tout le câblage doit être effectué par un élec-
tricien ou ingénieur en instrumentation qualifié. Voir le dia-
gramme pour désignations des bornes et des exemples de
câblage. Consulter l'usine pour assistance.
ATTENTION! Éviter les risques de choc! Fermez le signal
d'entrée, le signal de sortie et l'alimentation électrique avant
de connecter ou de déconnecter le câblage, ou de retirer ou
d'installer le module.
Internal Calibration Resistor
The APD 4059 CR has provisions for and internal shunt/calibra-
tion resistor. It can be ordered with the module or installed by
the user. The resistor value should match what is specified by
the transducer manufacturer.
The calibration resistor can be installed or changed in the field
if required by following the procedure below.
1. Remove all power from the APD 4059 CR, unplug all con-
nectors, and remove unit from DIN rail.
2. Using a small flat-blade screwdriver remove the front panel
as shown below.
3. Note the locations of the seven tabs attaching the side cover.
4. Using a small flat-blade screwdriver gently pry the tab ends
away from the housing. Start with the large tab at the rear
of the unit, and work towards the front while gently pulling
up on the side cover.
5. When all tabs are unlatched, remove the side cover.
6. To remove the calibration resistor (if one was installed), pull
it out of its holder. The calibration resistor should have the
leads cut and bent to fit the calibration resistor holder.
7. Align the side cover and snap into place making sure all
seven tabs are engaged. Snap front cover back into place.
Reinstall unit.
Internal Calibration Resistor
Range Selection
It is generally easier to select ranges before installing the mod-
ule on the DIN rail. The tables list available settings for excita-
tion voltages, ranges and offsets. Any custom range settings
will be listed on the module's serial number label
Use the rotary switches and a slide switches on the side of the
module to select input and output ranges for your application.
Switch A:
Excitation voltage
Switch B:
Input range
Switch C:
Input offset
Switch D:
Output range
Switch E :
Set to "V" for voltage output or
Set to "I" for current output
Determine how much output in millivolts the load cell will pro-
duce at full load. Multiply the manufacturer's mV/V sensitivity
specification by the applied excitation voltage.
For example, a load cell rated for 3 mV/V sensitivity using 10
VDC excitation will produce an output of 0 to 30 mV for load
variations from 0 to 100%.
3 mV/V sensitivity X 10 VDC excitation = 30 mV range
Switch A Excitation Voltage
Refer to the sensor manufacturer's
recommendations to determine what
excitation voltage to use.
Set Excitation rotary switch A to
desired excitation voltage.
After installation the Excitation fine
adjust potentiometer may be used to
precisely trim this voltage, if desired.
I/O Range Selection
Switches B, D, E
1. From the table at the bottom of the page, find the rotary
switch combination that matches your I/O ranges and set
rotary switches B and D.
2. For taring, deadweight, zero offset, or a bipolar sensor
refer to the "Offset Switch C" section below. Otherwise set
switch C to zero.
3. Set switch E to "V" for voltage output or "I" for current output.
4. For ranges that fall between the listed ranges use the next
highest setting and trim the output signal with the zero and
span potentiometers as described in the Calibration section.
Using Offset Switch C
Offset switch C allows canceling or taring of non-zero dead-
weights or other sensor offsets such as:
O
Compensate for tare weights or scale deadweight to get
zero output when a load is on the platform.
O
Compensate for low-output sensors (e.g., less than 1 mV/V)
that may have large zero offsets. Switch C can realign
the zero control so it has enough range to produce a zero
output.
O
Raising the offset to allow calibration of bipolar sensors
such as ±10 mV.
O
Lowering the offset to compensate for elevated input ranges
such as 10-20 mV.
1. Switch C does not interact with
any other switch and is the only
switch needed to correct zero
offsets. Its only purpose is to
adjust or cancel effects of the
low end of the input range not
corresponding nominally to 0 mV.
Setting this switch to “0” results
in no offset.
2. To RAISE the output zero, rotate
switch C from “1” thru “7”, until
the Zero control can be set for
your application.
3. To LOWER the output zero, rotate
switch C from “9” thru “F”, until
the Zero control can be set for
your application.
4. If switch positions are changed,
repeat the calibration procedure on the last page.
Precautions, Calibration Resistor, Range Setup
APD 4059 CR
Output
0-1 V
0-2 V
0-4 V
1-5 V
0-5 V
0-8 V
2-10 V 0-10 V
±5 V
±10 V 0-2 mA 0-4 mA 0-8 mA 2-10 mA 0-10 mA 0-16 mA 4-20 mA 0-20 mA
Switches
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
BCDE
Input
0-5 mV
200V
208V
201V
206V
209V
202V
207V
203V
204V
205V
200I
208I
201I
206I
209I
202I
207I
203I
0-10 mV
A00V
A08V
A01V
A06V
A09V
A02V
A07V
A03V
A04V
A05V
A00I
A08I
A01I
A06I
A09I
A02I
A07I
A03I
0-20 mV
300V
308V
301V
306V
309V
302V
307V
303V
304V
305V
300I
308I
301I
306I
309I
302I
307I
303I
0-25 mV
600V
608V
601V
606V
609V
602V
607V
603V
604V
605V
600I
608I
601I
606I
609I
602I
607I
603I
0-30 mV
E00V
E08V
E01V
E06V
E09V
E02V
E07V
E03V
E04V
E05V
E00I
E08I
E01I
E06I
E09I
E02I
E07I
E03I
0-40 mV
B00V
B08V
B01V
B06V
B09V
B02V
B07V
B03V
B04V
B05V
B00I
B08I
B01I
B06I
B09I
B02I
B07I
B03I
0-50 mV
000V
008V
001V
006V
009V
002V
007V
003V
004V
005V
000I
008I
001I
006I
009I
002I
007I
003I
0-100 mV
800V
808V
801V
806V
809V
802V
807V
803V
804V
805V
800I
808I
801I
806I
809I
802I
807I
803I
0-120 mV
F00V
F08V
F01V
F06V
F09V
F02V
F07V
F03V
F04V
F05V
F00I
F08I
F01I
F06I
F09I
F02I
F07I
F03I
0-200 mV
100V
108V
101V
106V
109V
102V
107V
103V
104V
105V
100I
108I
101I
106I
109I
102I
107I
103I
0-250 mV
400V
408V
401V
406V
409V
402V
407V
403V
404V
405V
400I
408I
401I
406I
409I
402I
407I
403I
0-300 mV
C00V
C08V
C01V
C06V
C09V
C02V
C07V
C03V
C04V
C05V
C00I
C08I
C01I
C06I
C09I
C02I
C07I
C03I
0-400 mV
900V
908V
901V
906V
909V
902V
907V
903V
904V
905V
900I
908I
901I
906I
909I
902I
907I
903I
Remove front cover with
flat-blade screwdriver
1
2
3
4
5
6
7
Calibration resistor holder
Calibration resistor
Excitation Switch A
10 V
A
9 V
9
8 V
8
7 V
7
6 V
6
5 V
5
4 V
4
3 V
3
2 V
2
1 V
1
0 V
0
Offset
% of Span Switch C
105%
7
90%
6
75%
5
60%
4
45%
3
30%
2
15%
1
0%
0
–15%
9
–30%
A
–45%
B
–60%
C
–75%
D
–90%
E
–105%
F
api-usa.com
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
Fax: 800-949-7502
A
A
BSOLUTE
BSOLUTE
P
P
ROCESS
ROCESS
I
I
NSTRUMENTS
NSTRUMENTS
API maintains a constant effort to upgrade and improve its products.
Specifications are subject to change without notice. See api-usa.com for
latest product information. Consult factory for your specific requirements.
WARNING:
This product can expose you to chemicals includ-
ing nickel, which are known to the State of California to cause
cancer or birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov