8
DESCRIPTION OF CONTROLS
REAR PANEL
13)
Normal/Bridge
: this switch must be engaged when using a bridged amp (32db
gain)
14)
Sub Input:
When this switch is released, the subwoofer derives its input from the
sum of inputs A and B; when it is engaged; it receives the signal from an external
source (such as a mixer's auxiliary send).
NB
:
For proper operation of the protection circuitry, the gain of the amplifiers must
be 26dB. Most amplifiers provide this gain as standard.
Warning: Excessive gain may result in speaker damage.
In particular, bridged amps exhibit a gain 6db higher than standard.
When using bridged amps it is necessary to use one of the following process:
Use the button normal/bridge situated on the rear panel
Modify the amp's gain structure,
Use a 6 db input attenuator,
Turn the amp's potentiometer down 6 dB
APG, TG29, TG32, attenuators & TGxx (custom made), for 29dB, 32dB or other value
are available on order.
All inputs and outputs are electronically balanced: the connectors are 3 pin XLR'S
The mains receptacle is an EEC type with the center prong connected to ground. For
obvious safety reasons, it should always be connected.
The processors can be operated continuously; thus they do not have a mains switch.
The processor uses a hum loop eliminator. If any hum or buzz occurs, it is not caused by a
ground loop
F) When replacing mains fuse, type & value must be identical as indicated bellow:
220-240Vac
0,1 A Temp.
100-126Vac
0,2 A Temp.