●Be sure to confirm the Power Supply Harness is securely connected in both
the Sensor Unit and Meter Display Unit.
●Be sure to confirm the COM Harness is securely connected in both the
Sensor Unit and Meter Display Unit.
Meter Display does not turn on or
display anything when Ignition key
is ON.
Frequently Asked Question
Frequently Asked Question
Frequently Asked Question
Frequently Asked Question
12
12
12
12
Please check the following points after installation
Please check the following points after installation
Please check the following points after installation
Please check the following points after installation:
:
:
:
●Check the Sensor and Senor Connection Harness.
●Check the Illumination Power Signal Wire of the Power Supply Harness.
●Calibration of the sensor is required when Pressure Meter does not display
“0” at atmospheric pressure. (See Below)
【
Method
】
Turn Ignition [ON] – without turning the engine on. Wait for at least 10
seconds. (during this time, the unit will calibrate the value to “0”). When
sensor calibration is completed,“
CAL”
will appear on the digital meter
display for at least 1 second. If engine is turned on before 10 seconds, then
the sensor calibration procedure will need to be repeated.
Check each Sensor harness and Sensor again.
Main Display Unit or Sensor Unit may have
operation failure, please consult with your dealer of
purchase.
Temperature displays ”
--.-”
when the temperature is at freezing point (below
0℃)
or when the temperature sensor is disconnected or not securely connected.
Pressure displays ”
-.--”
when the pressure sensor is disconnected or not securely
connected.
Check the Sensor Harness connections.
The analog needle of the meter
display does not move or is moving
abnormally.
Display brightness does not change
when parking lights are turned ON.
If Pressure Meter displays a value
that is not “0” at atmospheric
pressure (engine turned off).
Digital Meter shows “
Err”
Digital Meter display shows:
“
--.-”
or ”―
.--”
Installation Confirmation
Installation Confirmation
Installation Confirmation
Installation Confirmation
8
8
8
8
Operation Confirmation
Operation Confirmation
Operation Confirmation
Operation Confirmation
9
9
9
9
● Turn Ignition to the [ON] position, check to make sure the meter display
needle sweeps up and back down.
● Turn Ignition to the [ON] position, check to make sure the LED indicators
change color.
● Turn Ignition to the [ON] position, check to make sure the Digital Meter
numerical values are displayed in 1,2,…order sequence, and back to zero.
● Make sure the pressure sensor is calibrated.
※ Refer to [Frequently Asked Question] for calibration method.
● Please check for any unusual noise or odor coming from the unit.
● Once the engine is running, be sure to check for water or oil leaks.
● Once the engine is running, be sure to check that there is no interference
for each individual part.
Meter Display Functions
Meter Display Functions
Meter Display Functions
Meter Display Functions
10
10
10
10
Diagram: A-1
(Needle line will display bright on actual measured value。)
Meter Indicators (Analog)
Diagram: A-2
(The analog indicator will illuminate less than the measured
value needle indicator line)
Diagram: A-3
(Needle indicator line in over scaling display)
● Meter parameters are displayed in a real-time analog needle display
(As shown in Diagram: A-1 & A-2). When the measured value
exceeds the numerical value displayed, the analog needle will
transition into an over-scale display (Temperature only). During the
over-scale display, the analog needle will illuminate brighter to
indicate the measured value (As shown in Diagram: A-3). However,
when only the indicator needle line is displayed as shown in
{Diagram: A-1}, the values will change.
Temperature 1・・・Normal Scale 30℃~130℃
Over-Scale 130℃~190℃
Temperature 2・・・Normal Scale 50℃~150℃
Over-Scale 150℃~190℃
● Analog needle indicator illumination setting can be turned On / Off.
※ The initial illumination setting is shown in Diagram: A-2.
Diagram:B-1
Digital Meter Parameters (Numerical)
● Each parameter can be displayed in digital numerical value.
● The Digital Numerical indicator can be turned On / Off.
※ At initial setting: all parameters are tuned On.
※ When the temperature sensor is: (below 0℃) or when the sensor is
disconnected, the display will show “--.-”
※ When the pressure sensor is disconnected, the display will show
“--.-”
Diagram: C-1
LED Indicators
● The color gradation settings of the LED Indicator can be changed to
corresponding numerical values.
※ Initial Settings: (Temperature) Blue→Green→Yellow→Red
(Pressure) Green→Yellow→Red
● A Warning Function can be preset for each LED Indicator.
● LED Indicator colors can be preset with user preferences, and also
to match the vehicle’s interior LED color, dashboard, console, etc…
※ LED Indicators can also be preset to be fixed on a single color.
※ The Warning Function indicator color will display when the measured value
exceeds the preset warning value.
● The LED Indicators can be turned On / Off.
※ At initial setting, the LED Indicators are turned On.
Diagram: C-2
③ Upper Right Corner「SET」
will be flashing.
LED Flashing
④ Press the Mode Switch、「SET」will be selected and lit.
LED lit
⑤ The setup of each display indicator can be changed by the following
procedure:
● Pressing Mode Switch.....to activate menu selection
Activating...Press the Mode Switch
Selecting ...Press the Mode Switch for over 2 seconds.
● Press the Peak Switch or Reset Switch
...to scroll through each display menu
Press Mode Switch
Individual Setup Menu Details
● Turning the Digital Meter On / Off
Turning ON ⇒ Press the Peak Switch or Reset Switch until「don」is displayed.
Turning OFF ⇒ Press the Peak Switch or Reset Switch until「doF」is displayed.
● Selecting Display Meter Features
・Selecting the Analog Indicator Display method as shown “Meter Indicators
(Analog)”
・Press the Peak Switch or Reset Switch to select display method.
Turning ON⇒「A-1」Needle line will display bright on actual measured value.
「A-2」The analog indicator will illuminate less than the measured
value needle indicator line.
Turning OFF⇒「AoF」Indicator display is turned OFF。
※ Scale indicator marks will not illuminate.
● Selecting the LED Indicator Features
Turning ON⇒「L1」Color Gradation Display
(Temp. Sensor) Blue→Green→Yellow→Red
(Pressure Sensor) Green→Yellow→Red
「L2~8」Selecting Various Colors.
※ The LED Indicator will not change when a fixed color is selected.
※ The Warning Function indicator color will display when the
measured value exceeds the preset value.
Turning OFF⇒「LoF」will display when the LED Indicator is turned OFF.
※ The Warning Function indicator color will display when the
measured value exceeds the preset value.
Analog and Digital Meter
(
LED Indicator OFF
)
Digital Meter Only
(
LED Indicator OFF
)
LED Indicator Only
(
Digital Meter OFF
)
Analog Only
(
Digital Meter + LED Indicator OFF
)
● After the above setup, when setting the meter for the Pressure Meter
display ONLY, “bon”or “boF”will display on the screen ,please select
“boF”.
● The Warning Function will activate when the measured value exceeds
preset values, the LED indicator will flash in Red Color.
● For Normal operating measured values, the LED Indicator can be
preset to show the LED indicator in Green Color.
※This preset can only be set when the LED Indicator is set on the 「L1」
Color Gradation Setting.
● Be sure to reconnect the negative terminal of the battery.
● Please confirm that all wiring is secure and correct.
● Check for water or oil leaks.
● Check water and oil fluid levels and confirm they are up to specification.
● Make sure that the Meter Display and Sensor Unit have been securely
mounted.
● Check to make sure that the harness does not run near any moving parts.
Secure the harness using zip ties so that wires do not get cut and cause
electrical shorts.
● Be sure to reinstall any parts removed for the installation process.
● Be sure to check for any tools or loose materials that may have been left
behind in the engine bay and vehicle cabin during installation.
Operational Procedures
Operational Procedures
Operational Procedures
Operational Procedures
11
11
11
11
The features of the Analog Meter, Digital Meter, and LED Indicators
can individually be preset by the following operational procedures.
Setup
① Press the Mode Switch
(about 1 sec.)
Press Mode Switch
② Press the Peak Switch or the Reset Switch, and select「SET」.
※ By Pressing the switches you can select、「WARN」・「BRT」 located
in the Upper Left Corner and「SET」located in the Upper Right Corner.
Press Peak Switch
Or
Press Reset Switch
Setup
① Press the Mode Switch
(about 1 sec.)
Press Mode Switch
② Press the Peak Switch or Reset Switch, and select「WARN」.
※ By pressing the switches you can select, 「WARN」・「BRT」located in the
Upper Left Corner and 「SET」located in the Upper Right Corner.
Press Peak Switch
Or
Press Reset Switch
③ Upper Left Corner「WARN」
will be flashing.
LED Flashing
④ Press the Mode Switch,「WARN」will be selected and Lit.
LED lit
Press Mode Switch
Individual Setup Menu Details
● Warning Function (LED Red Color)
Press the Peak Switch or Reset Switch when desired preset value is set
and the LED Indicator is showing in Red Color.
Warning Setting Range
Temp. 1・・・ 35℃~199℃
Temp. 2・・・ 55℃~199℃
Pressure ...0.0~9.5(×100kPa)
● Normal Operating Values (LED Green Color)
Press the Peak Switch or Reset Switch when desired preset value is set
and the LED Indicator is showing in Green Color.
Normal Setting Range
Temp. 1・・・ 30℃~194℃
Temp. 2・・・ 50℃~194℃
Pressure ...0.5~10.0(×100kPa)
≪Warning vs. Normal Value Setup≫
● For Temperature: the Normal value can be set at 5℃ under the preset
Warning value.
● For Pressure: the Normal value can be set at 0.5(×100kPa)above
the preset Warning Value.
※The Warning preset value will be priority over the Normal operating preset
value. If the Warning preset value is set too close to the Normal value, please
adjust preset values accordingly.
※In the case when the Normal Operating value is setup higher than the Warning
preset value, (Pressure
–
lower preset value), the unit will automatically adjust
to the below settings:
・For Temperature: Normal LED will be set at under 5℃ Warning Preset value.
・For Pressure: Normal LED will be set at over 0.5(×100kPa)Warning
Preset value.
≪Warning LED Flashing≫
The Warning Function is designed to alert the driver when the measured value
exceeds the warning preset value (Pressure: drops below preset value). The LED
indicator will flash in Red Color, even if the LED Indicator is turned OFF.
〈 Display Example 〉
Warning Preset Exceeded
LED flashes in Red Color
Err 01・・・・・
Internal Failure
Indicator Setup
Indicator Setup
Indicator Setup
Indicator Setup
Warning Function Setup
Warning Function Setup
Warning Function Setup
Warning Function Setup
Brightness adjustments for: Analog / Digital Meter Display, and Buttons.
Setup
① Press the Mode Switch (about 1 sec.)
Display/Button Brightness
Display/Button Brightness
Display/Button Brightness
Display/Button Brightness
Press Mode Switch
LED Flashing
② Press the Peak Switch or Reset Switch, and select「BRT」.
※ By Pressing the switches you can select 「WARN」・「BRT」located in
the Upper Left Corner and 「SET」located in the Upper Right Corner.
Press Peak Switch
Or
Press Reset Switch
③ Upper Left Corner「BRT」will
be flashing.
④ Press the Mode Switch,「BRT」will be selected and Lit.
LED lit
Press Mode Switch
⑤ The setup of each display indicator can be changed by the following
procedure:
● Pressing Mode Switch.....to activate menu selection.
Activating...Press the Mode Switch
Selecting ...Press the Mode Switch for over 2 seconds
● Press the Peak Switch or Reset Switch...to scroll through each display menu.
● Individual Setup Menu Details
・
Display Brightness (daytime) ...Digital Meter (left side) =>“dy1~9”
・
Display Brightness (nighttime)...Digital Meter (center) =>“dr1~9”
※The display brightness (nighttime) operates via the illumination signal wire.
※The display brightness (daytime) cannot be set lower than the display
brightness (nighttime).
※The display brightness (nighttime) cannot be set higher than the display
brightness (daytime).
・
Button Brightness and (ON / OFF) Adjustment
....Digital Meter (right side) => “IL0~5”
Button LED turned OFF => “IL0”
※Button brightness is the default setting regardless of day / night settings.
Setup
① Press the Peak Switch
All meters will display Peak Value.
※Unlike, the other Menu Setup processes, the Peak menu is as follows:
Peak
Peak
Peak
Peak-
--
-Hold Function
Hold Function
Hold Function
Hold Function
Press Peak Switch
● The Peak Hold Function records the maximum measured value.
● Unless reset, the Peak Hold value will remain in memory even when the power is
turned off.
② Press the Peak Switch again, this will return back to real-time display.
Peak Value will remain in memory until reset.
Resetting the Peak Hold Value
① Press the Reset Switch (over 1 sec.)
while in Peak Hold Mode.
② 「PEAK」LED on display will flash, then stay lit. This will reset the Peak Hold
value.
Press Reset Switch
⑤ The setup of each display indicator can be changed by the following
procedure:
● Pressing Mode Switch.....to activate menu selection
Turning ON...Press the Mode Switch
Turning OFF...Press the Mode Switch for over 2 seconds.
● To set Warning Preset Values...Press the Peak Switch or Reset Switch
Raising the Preset Value ...Press the Peak Switch
Lowering the Preset Value...Press the Reset Switch
・ Digital Meter (numerical)・・・All Peak Values shown.
・ Analog Meter・・・・・・・・Peak values are shown as Diagram「A-2」.
・ LED Indicator ・・・Peak values are shown as Color Gradation「L1」.
In Peak Hold mode, 「PEAK」will be lit on the display Upper Right Corner.
Symptoms
Symptoms
Symptoms
Symptoms
Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Err 02・・・・・
Communication Error
Err 03・・・・・
Communication Error
P.
P.
P.
P.5
5
5
5
P.
P.
P.
P.7
7
7
7
P.
P.
P.
P.6
6
6
6
P.
P.
P.
P.8
8
8
8