APEXi DIN 3 METER Instruction Manual Download Page 2

●Be sure to confirm the Power Supply Harness is securely connected in both 

the Sensor Unit and Meter Display Unit. 

●Be sure to confirm the COM Harness is securely connected in both the 

Sensor Unit and Meter Display Unit.  

Meter  Display  does  not  turn  on  or 
display  anything  when  Ignition  key 
is ON. 

 

Frequently Asked Question

Frequently Asked Question

Frequently Asked Question

Frequently Asked Question    

12

12

12

12 

  

 

Please check the following points after installation

Please check the following points after installation

Please check the following points after installation

Please check the following points after installation:

:    

●Check the Sensor and Senor Connection Harness.  

●Check the Illumination Power Signal Wire of the Power Supply Harness. 

●Calibration of the sensor is required when Pressure Meter does not display 

“0” at atmospheric pressure. (See Below) 

 

Method

Turn Ignition [ON] – without turning the engine on. Wait for at least 10 

seconds. (during this time, the unit will calibrate the value to “0”). When 
sensor calibration is completed,“

CAL”

will appear on the digital meter 

display for at least 1 second. If engine is turned on before 10 seconds, then 
the sensor calibration procedure will need to be repeated.

 

Check each Sensor harness and Sensor again. 

 

Main Display Unit or Sensor Unit may have 
operation failure, please consult with your dealer of 
purchase. 

 

Temperature displays ”

--.-”

when the temperature is at freezing point (below 

0℃) 

or when the temperature sensor is disconnected or not securely connected. 

Pressure displays ”

-.--”

when the pressure sensor is disconnected or not securely 

connected. 

Check the Sensor Harness connections. 

 

The   analog   needle   of   the   meter 
display  does  not  move  or  is  moving 
abnormally. 

 

Display  brightness  does  not  change 
when parking lights are turned ON. 

 

If  Pressure  Meter  displays  a  value 
that   is   not   “0”   at   atmospheric 
pressure (engine turned off). 

 

Digital Meter shows “

Err”  

Digital Meter display shows:  

--.-” 

or ”―

.--”  

Installation Confirmation

Installation Confirmation

Installation Confirmation

Installation Confirmation    

8 

  

 

Operation Confirmation

Operation Confirmation

Operation Confirmation

Operation Confirmation    

9 

  

 

●  Turn  Ignition  to  the  [ON]  position,  check  to  make  sure  the  meter  display 

needle sweeps up and back down. 

●  Turn  Ignition  to  the  [ON]  position,  check  to  make  sure  the  LED  indicators 

change color. 

●  Turn  Ignition  to  the  [ON]  position,  check  to  make  sure  the  Digital  Meter 

numerical values are displayed in 1,2,…order sequence, and back to zero. 

● Make sure the pressure sensor is calibrated. 

※ Refer to  [Frequently Asked Question] for calibration method. 

● Please check for any unusual noise or odor coming from the unit. 
● Once the engine is running, be sure to check for water or oil leaks. 
● Once the engine is running, be sure to check that there is no interference 

for each individual part. 

Meter Display Functions

Meter Display Functions

Meter Display Functions

Meter Display Functions    

10

10

10

10 

  

 

Diagram: A-1

(Needle line will display bright on actual measured value。) 

Meter Indicators (Analog) 

Diagram: A-2 

(The analog indicator will illuminate less than the measured 

value needle indicator line)

 

Diagram: A-3

(Needle indicator line in over scaling display) 

●  Meter  parameters  are  displayed  in  a  real-time  analog  needle  display 

(As   shown  in  Diagram:   A-1  &  A-2).  When  the   measured  value 
exceeds   the   numerical   value   displayed,   the   analog   needle   will 
transition  into  an  over-scale  display  (Temperature  only).  During  the 
over-scale   display,   the   analog   needle   will   illuminate   brighter   to 
indicate the measured value (As  shown in Diagram:  A-3). However, 
when   only   the   indicator   needle   line   is   displayed   as   shown   in 
{Diagram: A-1}, the values will change. 

 

Temperature 1・・・Normal Scale   30℃~130℃ 

Over-Scale    130℃~190℃ 

Temperature 2・・・Normal Scale   50℃~150℃ 

Over-Scale   150℃~190℃ 

● Analog needle indicator illumination setting can be turned On / Off. 
     ※  The initial illumination setting is shown in Diagram: A-2. 

Diagram:B-1

 

Digital Meter Parameters (Numerical)  

● Each parameter can be displayed in digital numerical value. 
● The Digital Numerical indicator can be turned On / Off. 

※ At initial setting: all parameters are tuned On. 
※  When  the  temperature  sensor  is:  (below  0℃)  or  when  the  sensor  is 

disconnected, the display will show “--.-” 

※  When  the  pressure  sensor  is  disconnected,  the  display  will  show 

“--.-” 

Diagram: C-1 

LED Indicators 

● The color gradation settings of the LED Indicator can be changed to 

corresponding numerical values. 

※ Initial Settings: (Temperature)  Blue→Green→Yellow→Red 

(Pressure)       Green→Yellow→Red 

● A Warning Function can be preset for each LED Indicator. 
●  LED  Indicator  colors  can  be  preset  with  user  preferences,  and  also 

to match the vehicle’s interior LED color, dashboard, console, etc…  

※ LED Indicators can also be preset to be fixed on a single color. 
※ The Warning Function indicator color will display when the measured value 

exceeds the preset warning value.  

● The LED Indicators can be turned On / Off. 

※ At initial setting, the LED Indicators are turned On. 

Diagram: C-2 

③  Upper Right Corner「SET」

will be flashing.

 

LED Flashing

 

④  Press the Mode Switch、「SET」will be selected and lit.

 

LED lit

 

⑤  The setup of each display indicator can be changed by the following 

procedure: 

●  Pressing Mode Switch.....to activate menu selection  

Activating...Press the Mode Switch 
Selecting  ...Press the Mode Switch for over 2 seconds. 

 ●  Press the Peak Switch or Reset Switch 

...to scroll through each display menu 

Press Mode Switch

 

Individual Setup Menu Details 

● Turning the Digital Meter On / Off 

Turning ON    ⇒  Press the Peak Switch or Reset Switch until「don」is displayed. 
Turning OFF    ⇒  Press the Peak Switch or Reset Switch until「doF」is displayed. 

● Selecting Display Meter Features  

・Selecting the Analog Indicator Display method as shown “Meter Indicators 

(Analog)” 

・Press the Peak Switch or Reset Switch to select display method. 

Turning ON⇒「A-1」Needle line will display bright on actual measured value. 

「A-2」The analog indicator will illuminate less than the  measured 

value needle indicator line.  

Turning OFF⇒「AoF」Indicator display is turned OFF。 

※ Scale indicator marks will not illuminate.  

● Selecting the LED Indicator Features  

Turning ON⇒「L1」Color Gradation Display 

(Temp. Sensor)      Blue→Green→Yellow→Red 
(Pressure Sensor)    Green→Yellow→Red 

「L2~8」Selecting Various Colors. 

※ The LED Indicator will not change when a fixed color is selected. 

※ The Warning Function indicator color will display when the 

measured value exceeds the preset value. 

Turning OFF⇒「LoF」will display when the LED Indicator is turned OFF. 

※ The Warning Function indicator color will display when the 

measured value exceeds the preset value. 

Analog and Digital Meter 

LED Indicator OFF

) 

Digital Meter Only 

 LED Indicator OFF

)  

LED Indicator Only 

 Digital Meter OFF

) 

Analog Only 

Digital Meter + LED Indicator OFF

) 

●  After the above setup, when setting the meter for the Pressure Meter 

display ONLY, “bon”or “boF”will display on the screen ,please select 
“boF”.

 

● The Warning Function will activate when the measured value exceeds 

preset values, the LED indicator will flash in Red Color. 

●  For  Normal  operating  measured  values,  the  LED  Indicator  can  be 

preset to show the LED indicator in Green Color. 

※This preset can only be set when the LED Indicator is set on the 「L1」

Color Gradation Setting.  

● Be sure to reconnect the negative terminal of the battery. 
● Please confirm that all wiring is secure and correct. 
● Check for water or oil leaks. 
● Check water and oil fluid levels and confirm they are up to specification. 
● Make sure that the Meter Display and Sensor Unit have been securely 

mounted. 

● Check to make sure that the harness does not run near any moving parts. 

Secure the harness using zip ties so that wires do not get cut and cause 
electrical shorts. 

● Be sure to reinstall any parts removed for the installation process. 
● Be sure to check for any tools or loose materials that may have been left 

behind in the engine bay and vehicle cabin during installation.  

Operational Procedures

Operational Procedures

Operational Procedures

Operational Procedures

 

    

11

11

11

11 

  

 

The features of the Analog Meter, Digital Meter, and LED Indicators 
can individually be preset by the following operational procedures. 

Setup 

①  Press the Mode Switch 

(about 1 sec.) 

Press Mode Switch

 

②  Press the Peak Switch or the Reset Switch, and select「SET」. 

※  By Pressing the switches you can select、「WARN」・「BRT」 located 

in the Upper Left Corner and「SET」located in the Upper Right Corner.  

Press Peak Switch  
Or 
Press Reset Switch

 

Setup 

①  Press the Mode Switch 

(about 1 sec.) 

Press Mode Switch

 

②  Press the Peak Switch or Reset Switch, and select「WARN」. 

※ By pressing the switches you can select, 「WARN」・「BRT」located in the 

Upper Left Corner and 「SET」located in the Upper Right Corner. 

Press Peak Switch  
Or 
Press Reset Switch

 

③  Upper Left Corner「WARN」

will be flashing.

 

LED Flashing

 

④  Press the Mode Switch,「WARN」will be selected and Lit.

 

LED lit

 

Press Mode Switch

 

Individual Setup Menu Details 

● Warning Function (LED Red Color) 

Press the Peak Switch or Reset Switch when desired preset value is set 

and the LED Indicator is showing in Red Color.  

Warning Setting Range   

Temp. 1・・・  35℃~199℃ 
Temp. 2・・・  55℃~199℃ 
Pressure  ...0.0~9.5(×100kPa) 

● Normal Operating Values (LED Green Color) 

Press the Peak Switch or Reset Switch when desired preset value is set 
and the LED Indicator is showing in Green Color.

 

Normal Setting Range     

Temp. 1・・・  30℃~194℃ 

Temp. 2・・・  50℃~194℃ 
Pressure  ...0.5~10.0(×100kPa) 

≪Warning vs. Normal Value Setup≫  

● For Temperature: the Normal value can be set at 5℃ under the preset 

Warning value. 

● For Pressure: the Normal value can be set at 0.5(×100kPa)above 

the preset Warning Value. 

※The Warning preset value will be priority over the Normal operating preset 

value. If the Warning preset value is set too close to the Normal value, please 
adjust preset values accordingly. 

※In the case when the Normal Operating value is setup higher than the Warning 

preset value, (Pressure 

 lower preset value), the unit will automatically adjust 

to the below settings:  

・For Temperature: Normal LED will be set at under 5℃ Warning Preset value.   

・For Pressure: Normal LED will be set at over 0.5(×100kPa)Warning 

Preset value. 

≪Warning LED Flashing≫  

The Warning Function is designed to alert the driver when the measured value 
exceeds the warning preset value (Pressure: drops below preset value). The LED 
indicator will flash in Red Color, even if the LED Indicator is turned OFF.  

〈 Display Example 〉 

Warning Preset Exceeded 
LED flashes in Red Color 

Err 01・・・・・

Internal Failure 

 

Indicator Setup

Indicator Setup

Indicator Setup

Indicator Setup    

Warning Function Setup

Warning Function Setup

Warning Function Setup

Warning Function Setup    

Brightness adjustments for: Analog / Digital Meter Display, and Buttons. 

Setup 

①  Press the Mode Switch (about 1 sec.)

 

Display/Button Brightness

Display/Button Brightness

Display/Button Brightness

Display/Button Brightness    

Press Mode Switch

 

LED Flashing

 

②  Press the Peak Switch or Reset Switch, and select「BRT」. 

※ By Pressing the switches you can select 「WARN」・「BRT」located in 

the Upper Left Corner and 「SET」located in the Upper Right Corner.  

Press Peak Switch  
Or 
Press Reset Switch

 

③  Upper Left Corner「BRT」will 

be flashing.

 

④  Press the Mode Switch,「BRT」will be selected and Lit.

 

LED lit

 

Press Mode Switch

 

⑤  The setup of each display indicator can be changed by the following 

procedure:  

● Pressing Mode Switch.....to activate menu selection. 

Activating...Press the Mode Switch 
Selecting  ...Press the Mode Switch for over 2 seconds  

● Press the Peak Switch or Reset Switch...to scroll through each display menu.  
● Individual Setup Menu Details  

Display Brightness (daytime)  ...Digital Meter (left side) =>“dy1~9” 

Display Brightness (nighttime)...Digital Meter (center)  =>“dr1~9” 

※The display brightness (nighttime) operates via the illumination signal wire. 
※The display brightness (daytime) cannot be set lower than the display 

brightness (nighttime). 

※The display brightness (nighttime) cannot be set higher than the display 

brightness (daytime).  

Button Brightness and (ON / OFF) Adjustment  

....Digital Meter (right side)   =>  “IL0~5” 

Button LED turned OFF  => “IL0” 

※Button brightness is the default setting regardless of day / night settings.  

Setup 

①  Press the Peak Switch 

All meters will display Peak Value. 
 
 
※Unlike, the other Menu Setup processes, the Peak menu is as follows:

 

Peak

Peak

Peak

Peak-

--

-Hold Function 

Hold Function 

Hold Function 

Hold Function     

Press Peak Switch

 

● The Peak Hold Function records the maximum measured value.  
● Unless reset, the Peak Hold value will remain in memory even when the power is 

turned off. 

②  Press the Peak Switch again, this will return back to real-time display. 

Peak Value will remain in memory until reset.

 

Resetting the Peak Hold Value 

①  Press the Reset Switch (over 1 sec.) 

while in Peak Hold Mode. 

 
 

② 「PEAK」LED on display will flash, then stay lit. This will reset the Peak Hold 

value. 

Press Reset Switch 

 

⑤  The setup of each display indicator can be changed by the following 

procedure:  

● Pressing Mode Switch.....to activate menu selection 

Turning ON...Press the Mode Switch 
Turning OFF...Press the Mode Switch for over 2 seconds. 

● To set Warning Preset Values...Press the Peak Switch or Reset Switch 

Raising the Preset Value   ...Press the Peak Switch 
Lowering the Preset Value...Press the Reset Switch 

・ Digital Meter (numerical)・・・All Peak Values shown. 
・ Analog Meter・・・・・・・・Peak values are shown as Diagram「A-2」. 
・ LED Indicator  ・・・Peak values are shown as Color Gradation「L1」. 
In Peak Hold mode, 「PEAK」will be lit on the display Upper Right Corner. 

Symptoms 

Symptoms 

Symptoms 

Symptoms 

    

Troubleshooting

Troubleshooting

Troubleshooting

Troubleshooting    

Err 02・・・・・

Communication Error

     

Err 03・・・・・

Communication Error 

 

P.

P.

P.

P.5

5   

   

   

    P.

P.

P.

P.7

7    

    
P.

P.

P.

P.6

6   

   

   

    P.

P.

P.

P.8

8    

Reviews: