(1)
Select an item
Press the upper or lower part of the center switch and turn the rotary switch
counterclockwise or clockwise to select an item to set a numeric value. The selected
item is displayed as a reversing display. When the rotary switch is turned clockwise,
the cursor is moved upward. When this switch is turned counterclockwise, the cursor
is moved downward.
(2)
Set a numeric value
Select a numeric value and press the right part of the center to set the numeric value.
Press the upper or lower part of the center switch and turn the rotary switch
counterclockwise or clockwise to increase or decrease the numeric value. When the
rotary switch is turned clockwise, the numeric number is increased. When this switch
is turned counterclockwise, the numeric value is decreased.
⇒
For setting another item
Operate the left part of the center switch and repeat steps (1) and (2).
(3) End the setting
Select [Pr] in the popup menu after pressing the center pushbutton or press the left
part of the center switch at item selection (AflW, PrW, KarW, KnkW, RevW), and the
etc. menu will reappear.
■
Setting range
The value in parentheses is the initial value
A f l W
【
Airflow using ratio
】
50
〜
100 OFF (OFF)
[%]
※
Settable by 5% steps
P r W
【
Suction tube pressure
】
-500
〜
2.0 OFF (OFF)
[
kg/c
㎡]
※
Settable by 100 mmHg for the negative side
and 0.2 kg/cm
2
steps for the positive side
-100
〜
200 OFF (OFF)
[
kPa
]
※
Settable by 20 kPa steps
K a r W
【
Karman swirl sensor frequency
】
200
〜
1600 OFF (OFF)
[Hz]
※
Settable by 100 Hz steps
K n k W
【
Knocking
】
10
〜
200 OFF (OFF)
※
Settable by 20 steps
R e v W
【
Engine revolution speed
】
3000
〜
9000 OFF (OFF)
[
rpm
]
※
Settable by 500 rpm steps
Monitor mode
When the warning value for the
engine revolution speed is set to
5000 rpm.
A reversing/blinking display
is repeated.
When exceeding the set
warning value
・・・