Apelson ISLA90BK User Manual Download Page 22

22

07

08

Fix the vent pack using similar tape on the outlet (ducted option on a timber ceiling only).

Measure the correct required height of the hood for this installation. Fix the hanging brackets 

at the required length.

Min. 70cm

Max. 120cm

[08] x 16

[09] x 16

[10] x 32

Ø150mm

Vent Pack 2

Summary of Contents for ISLA90BK

Page 1: ...IE GB IE Curved Glass Island Hood USER MANUAL ISLA90SS Version 02...

Page 2: ...01 x 1 02 x 1 03 x 2 04 x 8 Cooker hood 08 x 16 09 x 16 05 x 1 10 x 40 11 x 4 07 x 06 6 x 50mm 4 x 6mm 5 x 10mm 06 x 1...

Page 3: ...ns Switching on off Care and maintenance Troubleshooting Recycling and disposal Technical and legal information 10 10 11 13 14 15 Appendix 20 Installation Information for EU66 17 26 3 These instructio...

Page 4: ...appliance from heating up during use and remaining hot during its operation Accessible parts may become hot during use Young children should be kept away Care should be taken to avoid touching the app...

Page 5: ...in order to avoid a danger or injury Do not allow the electric cables to touch the hot parts of the appliance Make sure that the power cord is not caught under or in the appliance and avoid damage to...

Page 6: ...and frequency coincide with that indicated on the appliance nameplate Warning The hood may stop working during an electrostatic discharge e g lightning This Warning Consult local regulations regarding...

Page 7: ...the cooker hood must be observed Gas hobs 750mm Electric hobs 650mm The Manufacturer declines all liability for personal or material damage as a result of misuse or incorrect installation of this app...

Page 8: ...appliance but contact Customer Services on 0344 800 1128 UK and 01 4475261 Ireland Check the package and make sure you have all of the parts listed Decide on the appropriate location for your product...

Page 9: ...u start GB IE 9 Getting started Accessories not supplied Recirculation TMFILT4 UK IE SELF ADHESIVE ALUMINIUM TAPE CARBON FILTER ORDERING HOTLINE 0344 800 1128 UK 014475261 IE Extraction 150mm VENT PAC...

Page 10: ...fter you have finished cooking Switching on off Electronic button panel On Off key of the power motor Power down key Power up key Delay key When motor is on working condition press one time to set 5 m...

Page 11: ...ork on the hood In the event of a fault contact customer services FUSE CARBON FILTER ORDERING HOTLINE 0344 800 1128 UK 014475261 IE 2 X ACTIVE CHARCOAL FILTER NOT SUPPLIED MODEL NUMBER TMFILT4 UK IE C...

Page 12: ...lot light lights up if fitted To do so remove the filters and soak in hot water and detergent for an hour If using a dishwasher position the filters vertically to improve the cleaning process Active c...

Page 13: ...m grease filter is dirty Clean filters See Care and maintenance section Replace with a bulb with correct rating Suction performance reduced Speed may be too low Select a higher speed Distance between...

Page 14: ...oduct must be handed over to an electric and electronic equipment collection point for recycling On ensuring that this product is disposed of correctly you will help to avoid possible negative consequ...

Page 15: ...AMP FUSE DOUBLE POLE SWITCHED FUSED SPUR OUTLET FUSE ON EUR UK Direct Connection If the appliance is being connected directly to the mains an omnipolar circuit breaker must be installed with a minimum...

Page 16: ...ectrical installation Electrical Connection Before connecting the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the appliance WARNING THIS APPLIANCE...

Page 17: ...electrical hazards DUCTED OPTION RECIRCULATION OPTION VENT PACK 150mm Choose a type of installation Ducted option extraction to the outside or recirculation option no extraction to the outside If fit...

Page 18: ...extremely important to check the ceiling for hidden pipes electrical cables etc using an appropriate detection device Ensure the ceiling and fixings used can support the weight of this appliance If in...

Page 19: ...recommended in this instruction manual Failure to follow these instructions may result in electrical hazards Mark and drill six holes 8mm in diameter according to the dimensions shown above Secure the...

Page 20: ...g to the dimensions shown on the diagram below Secure the top plate to the ceiling joist using suitable bolts nuts and washers not supplied Suitable fixings will be available from any reputable hardwa...

Page 21: ...is secured as above install the mains supply cable inside the plate Drill a hole for installation of the vent hose ducted option on a timber ceiling only Fix the one way valve to the air outlet of th...

Page 22: ...r tape on the outlet ducted option on a timber ceiling only Measure the correct required height of the hood for this installation Fix the hanging brackets at the required length Min 70cm Max 120cm 08...

Page 23: ...09 10 Place the lower chimney and upper chimney as shown 23 Mains lead...

Page 24: ...11 12 Fix the brackets onto the top plate using 8 screws Put up the upper chimney and fix it onto the bracket using 4 screws 24 11 x 4 11 10 x 8...

Page 25: ...25 13 For recirculating option refer to Care and maintenance section Note For electrical connection see Technical and legal information section Remove the protective film for Stainless Steel only...

Page 26: ...64 dB The measurement and calculation method of the above table was done in accordance with commission regulation EU No 65 2014 66 2014 B The following shows how to reduce total environmental impact...

Page 27: ......

Page 28: ...GB IE Apelson Appliances UK Limited Unit 3 Normandy Landings Pope St Castleford WF6 2AG...