Troubleshooting
Troubleshooting
If the lamp is failed please contact the after-sales care.
13
GB IE
In more detail...
Hood doesn’t
work.
No power supply.
Check the plug.
Check the main switch.
Care and
maintenance
section.
Motor running,
but no airflow
Repair to be carried out by
qualified service personnel only.
After running for
a while, motor
stop working.
High temperature safety
device activated.
the manufactures instructions.
Electric hobs: 30mm
Electric hobs: 30mm
Whirring sound. Fan blade probelm.
Repair to be carried out by
qualified service personnel only.
Poor airflow
Aluminum grease filters
are dirty.
Clean the filters. See
Butterfly valve jammed.
Ensure that the vent kit is fitted to
Oil leakage
One way valve and the air
ventilation entrance are
not tightly sealed.
Leakage from the
connection of U-shaped
section and cover.
Take down the one way valve
and seal with glue.
Take U-shaped section down
and seal with soap or paint.
Shake of the
body
The body is not tightly
hanged.
Fixed the body tightly.
The machine
inclines
The fixing screw not tight
enough.
Tighten the hanging screw and
make it horizontal.
The hanging screw not
tight enough.
Tighten the hanging screw and
make it horizontal.