How to Replace Stage-6 Carbon Filter:
Replace this last filter at the same time you replace the stage-4 membrane.
1) Remove the OLD filter:
See Fig. 15H.
Disconnect the output tubing from
point H
and tubing at
point K
. To remove the tubing, push in and hold down on the collet ring square against the fitting.
With the collet held in this position the tube can be removed.
2) Unclip the old filter from the membrane housing and discard the used filter.
3) Sanitize: Use some mild bleach solution to rinse the open ports of the new filter. This is to prevent
contamination.
NOTE:
Only this filter change needs bleach sanitizing.
Do not
apply chlorine/ bleach in any way to
Membrane for it will damage the membrane!
4) Connect New Filter:
See Fig. 15C.
Attach the new filter onto the clips. Make sure the
“FLOW
”
arrow
on the filter is pointing towards the pure water output direction
.
Reconnect the UV light output
point J
,
to the inlet of the 6
th
stage carbon
point K
. Then, connect the output tubing to
point H
.
5)
Check for leaks!
Fig. 15H
J
* * * End Filter Change Section * * *
K
H