![APART ZONE4 Instruction Manual Download Page 12](http://html1.mh-extra.com/html/apart/zone4/zone4_instruction-manual_2952013012.webp)
10
Pre-Amplifiers
22. Mic 2 balanced input on euroblock connector.
23. Mic 2 gain control:
from mic level to line level (e.g. wireless
microphone receivers).
24. Mic 1 balanced input connector with paging switch possibility.
The paging contact can also be used for mic 2 and 3. Closing
this contact mutes the music.
25. Mic 1 level control.
26. Mic 1 zone assign switch.
27. Mic 1 tone control.
28. Mic 1 input selector:
push the switch in/out to select the mic
connector on euroblock or the MICPAT-4 selective paging
station.
29.
RJ45 connector for the MICPAT-4 selective paging station only.
Up to 4 pcs. of MICPAT-4 can be connected to a single ZONE4.
A smart bus-sytem arranges the Priority (busy-line). Please refer
to the MICPAT4 manual.
30. Additional GND connecting screw.