APART MA200R Manual Download Page 6

WWW.APART-AUDIO.COM

3. Rear Panel

15)   Voltage selector. Set the local voltage:  If any doubt, contact your dealer.  The unit is shipped with the selec-

tor set to 230VAC.

16)   Mains socket: The unit can be connected to the mains circuit by a standard IEC type power cord.  This socket 

contains a 6,3AT, slow blow fuse.  Use a screw driver to flip out the fuse compartment and to replace it by the 

same type.  When this fuse blows frequently, you should check the speaker load or bring the MA200R to a 

qualified service centre.  First check whether you didn’t use a quick-blow fuse!

17)   Zone 100V loudspeaker outputs: When you need to activate/deactivate separate loudspeaker zones, you 

should use these 100V outputs.  These connectors should only be used for 100V operation.  They are 

activated by the selectors at the front (see 4).  Don’t use these 100V outputs together with the 8 ohm, 50V 

or 70V terminals. The minimum impedance of all 100V loudspeaker lines together should be at least 50Ω 

(100Vx100V/50Ω = 200watt).

18)   Emergency power supply: You can power the amplifier directly from an emergency battery or power supply 

supplying 24V DC/20A.

19)   Loudspeaker outputs: For low impedance use com and 8Ω.  Keep impedance above 8Ω. 

For 50, 70 or 100V speaker lines use COM and 50, 70 or 100V terminals. 

For 100V operation, the total minimum impedance of the loudspeaker lines should be 50 Ω.  For 70V opera-

tion the minimum impedance should be 24,5 Ω and for 50V 12,5 Ω. 

Don’t mix the types of speaker connections.  Only one at the time should be used, unless you are able to 

calculate a combination which does not overload the amplifier (example: 100Ω at 100V for a loud zone in 

combination with 25Ω at 50V for a quiet zone).

20)   24V DC output: At this terminal (-/+) 24V DC will be available (max. 1A) from the moment a priority has been 

activated, to control priority relays of local volume attenuators or other devices.

21)   Power amp in / pre amp out: You can send the signal of the pre-amplifier to an external device such as an 

equalizer (APart PXQ2215) or limiter and feed the treated signal back into the amplifier via the power amp 

input.  From the “pre-amplifier out” you can also feed extra power amplifiers such as the Apart PA240P.  Don’t 

forget to feed the signal back into the “power amp in”.  When you don’t use this feature, the RCA bridge 

should be placed.

22)   Tuner output mono: Here you can recover a fixed signal of the internal tuner to feed other devices such as 

your telephone’s ‘music on hold’ system.

23)   Rec. out: When you need a copy of the total mix, you can connect this output to any recording device such 

as tape deck, MD recorder, VHS recorder, etc….You can also use this output to feed an extra amplifier.  This 

output level cannot be controlled separately.  When you connect your MA200R pre amp out or record out 

to a microphone input of another mixing amplifier, this input will have signal overload and the sound will be 

masked.  In this case you should use a line input, a DI-box or other signal levelling device.  Never connect 

this output to an amplifier loudspeaker output!

16

15

18 19 20

33 32 28 30 31 27

36

17

21 22 24 25 26 26 27

27

28

23

29

34 35

Summary of Contents for MA200R

Page 1: ...INFO APART AUDIO COM MANUAL MA200R...

Page 2: ...ge source such as a battery mains source or power supply regardless of whether the amplifier or console is turned on or off Power down disconnect units from mains voltage before making connections Do...

Page 3: ...Content 1 APart MA200R Mixing Amplifier 2 Front Panel 3 Rear Panel 4 Tuner Controls 5 Inside Settings 6 Overview Of The MA200 Series 7 How To Deal With 100V Loudspeakers Systems 8 Technical Specificat...

Page 4: ...nd mutes all other signals except the emer gency input The third level can be activated via a dry contact priority over music and mutes all background music inputs only This contact activates the chim...

Page 5: ...RS phone jack has been wired in parallel with the other three input options for microphone 1 at the back For satisfying operation use only one of these inputs at the time for microphone 1 Microphone 1...

Page 6: ...eaker connections Only one at the time should be used unless you are able to calculate a combination which does not overload the amplifier example 100 at 100V for a loud zone in combination with 25 at...

Page 7: ...the DIN5 connector the signal of microphone 1 only has priority over the music sources TUNER CD and AUX All other microphones will remain active The contact closure of the contacts mentioned can give...

Page 8: ...rt to scan across the memory presets Each preset will be heard for about three seconds starting from the next preset till you reach the preset you where listening to again To stop this feature press S...

Page 9: ...hether the power cord has been inserted properly If these two have been checked and still the MA200R remains off the fuse might be blown No sound Check all the wires and loudspeaker selectors At least...

Page 10: ...ternal switch 4 line inputs 3 level priority system 24V priority output Integrated 2 tone chime adjustable volume 4 output zones Zone 4 Mic music selection Build in dynamic limiter 3 dB Dimensions 88...

Page 11: ...s on a 100Volt system not even one More technically When your paging amp has a maximum output of 200 watts at 100V this means that the minimum impedance connected should be at least 50 ohm 100x100 200...

Page 12: ...ED BY PRIORITY VOX Pre Amp 1V EMERGENCY TELEPHONE TRAFO VOLUME INPUT1 VOLUME INPUT2 VOLUME INPUT3 VOLUME INPUT4 VOLUME INPUT5 300mV TUNER OUT L R 500mV CD IN OUT L R 500mV AUX 200mV LINE 4 L R 1 5mV M...

Page 13: ...ED INDICATORS limiter active red signal 100 yellow signal 25 dB green power on green protection active red ZONE ACTIVE INDICATORS Z1 Z2 and Z3 green LED Z4 music on off orange Z4 paging allowed on off...

Page 14: ...QUENCY RESPONSE 100Hz 25Khz 1 3 dB MUTE mutes all 40 dB auX input Rca SENSITIVITY 500 MV 6 DB IMPEDANCE 22 K S N AT MAX VOLUME 80 DB FREQUENCY RESPONSE 40HZ 25KHZ 1 3 DB Line 4 Rca SENSITIVITY 200 MV...

Page 15: ...V tuneR Rca Mono Moh LEVEL 300 mV RecoRD out Rca Mono LEVEL 1 V pRioRity out LEVEL 24 V DC max 1A short circuit protected chiMe 2 tone activated by contact closure euro block DIN5 on off and level se...

Page 16: ...IO COM any SuGGeStion They are well appreciated and eventually rewarded Send your ideas or suggestions to suggestions apart audio com MA200R is developed by Audioprof nv Lanteernhofstraat 90 BE 2100 D...

Reviews: