APAR AR601 User Manual Download Page 2

 

Thank you for choosing our product. 

This user manual will help you with proper handling and safe 

operation of the controller. 

Before installation and first use please read this user manual with 

understanding. 

In case of additional questions please contact our technical advisor. 

 

Table of contents 

1. 

SAFETY PRECAUTIONS......................................................................  3 

2. 

INSTALLATION INSTRUCTIONS.........................................................  3 

3. 

AR601 CONTROLLER GENERAL CHARACTERISTICS...........................  3 

4. 

TECHNICAL SPECIFICATIONS.............................................................  4 

5. 

IMPORTANT USAGE INFORMATION.................................................  5 

6. 

HOUSING AND INSTALLATION METHOD.........................................  5 

7. 

TERMINAL STRIPS AND ELECTRICAL CONNECTIONS DESCRIPTION.  6 

8. 

BUTTONS, DISPLAY AND LED DESCRIPTION.....................................  6 

9. 

OUTPUT SETPOINT VALUE DISPLAY AND CHANGE..........................  7 

10. 

CONFIGURATION PARAMETERS SETUP............................................  7 

11. 

MESSAGES AND ERRORS LIST...........................................................  8 

12. 

ON-OFF CHARACTERISTICS TYPES....................................................  9 

13. 

PID REGULATION...............................................................................  9 

14. 

PID AUTOTUNING.............................................................................  10 

15. 

MANUAL PID PARAMETERS SELECTION...........................................  11 

16. 

PID PARAMETERS CORRECTION.......................................................  11 

 

 

 

 

 

Summary of Contents for AR601

Page 1: ...User Manual Temperature Controller AR601 Version 3 1 2013 02 13...

Page 2: ...STALLATION INSTRUCTIONS 3 3 AR601 CONTROLLER GENERAL CHARACTERISTICS 3 4 TECHNICAL SPECIFICATIONS 4 5 IMPORTANT USAGE INFORMATION 5 6 HOUSING AND INSTALLATION METHOD 5 7 TERMINAL STRIPS AND ELECTRICAL...

Page 3: ...ld be single point and connected as close to the device as possible Avoid placing test signal leads directly next to and parallel to power lines and supply cables It is recommended to twist signal wir...

Page 4: ...nt range 1 digit Thermocouple inputs additional 2 C cold ends temperature Response time 0 5 2s programmed by parameter 2 Relay outputs P1 For resistance loads 8A 250Vac For inductive loads 2A 250Vac F...

Page 5: ...achieve it is to connect suitable suppression module directly to inductive load contacts In general to each type of inductive load suitable suppression module should be selected Modern contactors are...

Page 6: ...display and change mode enter see section 9 Displayed errors deleting or Move to next previous parameter marked as UP or DOWN in manual Displayed errors deleting Available keys combinations SET DOWN...

Page 7: ...digits is possible using SET button Parameter 18 password can be changed After entering password correctly each press of SET button will display message and enter configuration parameters setup menu w...

Page 8: ...N 20 Display brightness step 10 Cautions 1 for response time is 0 5 second for response time is about 2 seconds Higher filtration level means more smooth measured value and longer response time 2 ON O...

Page 9: ...1 second The principle of operation for P type regulation proportional control for output P1 or SSR1 is shown in the illustration c d To select PID parameters suitable for certain regulation object i...

Page 10: ...m below actions Press SET button shortly then using UP button go to parameter After pressing SET button display will show selected parameter value OFF ON Pressing SET button simultaneously with UP or...

Page 11: ...between second and third oscillation 3 Set configuration parameters proportionality range P integration time T s differentiation time T 4 s pulsation period T 8 s 16 PID PARAMETERS CORRECTION Autotuni...

Reviews: