background image

 

 
 
 

USER INSTRUCTION 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 

 

UNIVERSAL TRANSDUCER 

 

AR594

 

 

 

 

              

 

 

 

Version 2.0.1 

2016.03.01

APAR - SALES OFFICE

 

05-090 Raszyn, ul. Gałczyńskiego 6, Poland 
Tel. 

+48 22 101-27-31, +48 22 853-49-30 

E-mail: 

[email protected] 

Website: 

www.apar.pl

 

 

Summary of Contents for AR594

Page 1: ...INSTRUCTION UNIVERSALTRANSDUCER AR594 Version 2 0 1 2016 03 01 APAR SALES OFFICE 05 090 Raszyn ul Ga czy skiego 6 Poland Tel 48 22 101 27 31 48 22 853 49 30 E mail automatyka apar pl Website www apar...

Page 2: ...TERMINAL STRIPSAND ELECTRICAL CONNECTIONS 6 8 LOCATIONAND DESCRIPTION OF ELEMENTS OF THE FRONT PANEL 6 9 SETTING OF THE CONFIGURATION PARAMETERS 7 10 CONFIGURATION OF THEALARM OUTPUT 9 11 SIGNALING OF...

Page 3: ...inity of and parallel to power distribution and power supply cables it is recommended to use twisted pair signal cables in the case of sensing resistors in 3 wire connections use identical wires avoid...

Page 4: ...9 4 CONTENTS OF THE SET a transducer with a set of connections a user instruction a warranty card 5 TECHNICAL DATA 1 universal programmable input measurement range Pt100 RTD 3 or 2 wire 200 850 C Ni10...

Page 5: ...range 0 90 C no condensation Protection rating IP20 Operating position any Weight approx 70 g Separation in out sup 1 5 kV 50 Hz 1 min Electromagnetic compatibility EMC immunity according to the PN EN...

Page 6: ...interface with a 120 resistor termination switched on when JP1 is closed 8 LOCATIONAND DESCRIPTION OF ELEMENTS OF THE FRONT PANEL Table 8 Description of the elements of the front panel Symbol Descrip...

Page 7: ...485 converter or the AR956 programmer restart the computer if the AR955 programmer is used instead of the AR956 programmer connect the power supply voltage to the transducer 2 Use the autonomous AR950...

Page 8: ...1 800 C 8 tc r thermoelectric sensor thermocouple type R 40 1 600 C 9 tc t thermoelectric sensor thermocouple type T 25 350 C 10 tc E thermoelectric sensor thermocouple type E 25 740 C 11 tc n thermo...

Page 9: ...m characteristics for the OC output is determined by parameter 5 oVt1 see chapter 9 Table 9 For oVt1 retr the OC output is connected after the measured value exceeds the range defined by parameters 8...

Page 10: ...he lines or clamps JP1 closed see chapter 7 Equipment from different manufacturers that form the RS485 network e g RS485 converters USB may have integrated polarizing and terminating resistors in such...

Page 11: ...mber Example 14 5 Error frame for a non existing read register address 0x01 0x84 0x02 0x0001 0x5130 Table 14 6 Map of registers for the MODBUS RTU protocol Register address HEX DEC Value HEX or DEC De...

Page 12: ...munication with the device via the PR port AR956 or AR955 The detailed descriptions of the aforementioned applications can be found in the installation folders NOTE Before a connection is established...