APAR AR232.B User Manual Download Page 12

12

 

Access protection  

to archive data and 
configuration 
parameters via USB port  

disabled

 - data disk available, password for ARSOFT-CFG and LOG disabled 

disabled 

full 

- disk not available for exploration, password for ARSOFT-CFG and LOG enabled 

for files only 

- disk not available, password for ARSOFT-CFG and LOG disabled 

Data access password 

0 ÷ 9999

 

used for configuration in ARSOFT-CFG and for reading archives in 
ARSOFT-LOG, depending on the 

Access protection

 parameter 

1111 

Bluetooth 

off 

status of the (optional) Bluetooth module indicated by the 

[BLE]

 icon 

(detailed description in the table in chapter 6, point b and in ch. 9.4.1)  

off 

on 

Notes:   
(1)

 - memory status is presented in the following format:  

           - upper row: the 

method of recording

 (symbol 

o

 = infinite, no symbol = until the memory is full, chapter 9.2),  

              

amount of occupied

 memory [%] 

           - bottom row: 

how long is it enough for

 (symbol 

h

 = hours, 

d

 = days, 

M

 

 = months, time calculated on the basis of  

              parameter 

Data recording interval

 and the amount of available memory, non-archive and additional files  

              catalogues’ structures reduce the capacity), for an circular (endless) record it is always the maximum value 

(2)

 - statistics are presented according to the description of the parameter 

Value for the upper

 and 

lower display

 (ch. 9.3) 

(3)

 – presentation format of the 

HOLD

 function (stopping the measurements): 3-digit value + symbol 

H

 and LCD icons 

(4)

 - the function automatically changes the 

Recording type 

parameter

 

to the 

disabled 

or

 continuous

 value (Table 9.2) 

(5)

 - deleting statistics and alarm memory with the 

F

+

START/STOP

 buttons is indicated by the message 

StAL

  

cLEA

 

(6)

 - the parameter or value does not appear in AR232.B 

 

9.4.1. HANDLING

 

BLUETOOTH RADIO COMMUNICATION (BLE)

 

Bluetooth wireless communication (BLE) enables remote reading of the current measured values and the recorder's 
battery level with the use of a mobile device (smartphone or tablet) with Android or iOS system and an available 
application. This functionality can be useful and convenient when the recorder is placed out of the user's reach (e.g. in a 
different room, outside or in a cold room, fridge, warmer or oven), while providing access to measurement data without 
disturbing the climatic conditions at the place of assembly, which could happen if the door is opened in order to read the 
display indications. 
Activation of the (optional) BLE interface requires the

 

Bluetooth 

parameter to be set to 

on

 value or programming the 

button

 

function 

with the 

Bluetooth turn on/off

 value, chapter 9.4.  The recorder is visible under the name 

Smart

 

Humigadget and can be connected to any compatible device within the BLE range, without a password. 
To save battery, it is recommended to provide good range with a connected mobile device and turn off the module when 
Bluetooth communication is not used (

 

the effect of BLE on battery life is given in chapter 4, note 2). 

The free application

 Sensirion

 

MyAmbience

 (English version) for mobile devices can be downloaded from Google Play (for 

Android) and from the App Store (for iOS). The application is dedicated to devices such as 

Smart Gadget

 with Sensirion 

humidity and temperature sensors. The program allows you to establish connections with several recorders at the same 
time (maximum 5, depending on the type of mobile equipment), while the recorder currently connected to one mobile 
device is not visible to others (until disconnection). In order to add recorders to the 

Smart Gadgets

 list, you can use the 

Add 

new device

 option and give your own names (

Gadget name

). For the device selected at the moment, the measurements 

are presented in the form of a board (

Dashboard

) or a graph (

Plot

) with additional archiving in the memory of the 

smartphone/tablet. The devices of the AR23x.B series do not support the function of setting the recording

 

interval

 

(Logging interval

) and synchronization of archived data (

Sync now

) offered by the application. In addition, for AR232.B 

humidity (

HUMIDITY

) always takes the value of 

0%RH

.  For uninterrupted transmission, data update takes place every 5s.  

In case of connection problems, check the Bluetooth settings in the devices and/or restart the 

MyAmbience

 application. 

 

9.5. ALARMS' CONFIGURATION

 

The recorder allows signalling the 

current alarms and alarms stored for relative humidity and sensor's temperature

 with 

short LED diode flashes and optionally with pulsating sounds, repeated every 1s or 5s. Programmable alarm characteri-
stics are presented in the table below. 

Alarms memory

 can be useful for detecting exceeding that has occurred in the 

past. In addition, it is possible to set the 

Insensitivity time

 (postponement of alarm checking) after resetting the alarm 

memory, which allows stabilization of measurements and prevention of premature alarms after placing the device in the 
target place (e.g. in a cold room) or just disable alarms for defined time using buttons. The alarm memory can be reset by 

Summary of Contents for AR232.B

Page 1: ...6 B AR232 B BATTERY POWERED RECORDERS OF HUMIDITY AND OR TEMPERATURE Version 2 0 4 2019 03 13 APAR SALES OFFICE 05 090 Raszyn ul Ga czy skiego 6 Tel 22 101 27 31 22 853 49 30 E mail automatyka apar pl...

Page 2: ...E INSTALLATION 8 9 SETTING CONFIGURATION PARAMETERS 8 9 1 INTERNAL CLOCK OPTIONS 9 9 2 RECORDING OPTIONS 9 9 3 DISPLAY AND MEASUREMENTS OPTIONS 10 9 4 BUTTONS FUNCTIONS AND ACCESS OPTIONS 11 9 4 1 HAN...

Page 3: ...vice portable casingwith a handle for easy mounting on vertical and horizontal surfaces after using an additional table base or other user s solutions two line readable LCD display with icons and meas...

Page 4: ...u can also buy it through the online storeapar sklep pl 3 6V lithium battery type AA R6 2450mAh e g SAFT type LS14500 table base standing NOTE before working with the recorder read this user manual pe...

Page 5: ...etails inchapter 5 77x111x32 mm withoutprobe and hanging holder Operating position any positionor sensor cover down whenthe probe is exposed to directcontact with water Weight 150g withbattery and pro...

Page 6: ...r when condensation on the device is possible e g after taking out from the fridge Wait until the recorder reach ambient temperature to avoid potential malfunction If necessary during this time record...

Page 7: ...iconof the USB transmissionand recording readingof the recorder s memory 6 saving the archive file is active REC registrationstatus icon missing in progress or pause registration options are describe...

Page 8: ...ice from the computer before the installationof the drivers is completed connection of the recorder to the USB portof the computer stops the recordinguntil the cable is disconnected and blocks a previ...

Page 9: ...urry or late Dischargingand replacementor lackof battery causes the clock to be reset and requires setting time and date againafter the power is restored Table 9 1 Parameters of the internal time cloc...

Page 10: ...r calculated value dew frostpoint to besaved inthe archive file descry ptionoftherecord in chapter10 sensor s temperature C dew frostpointtemperature C F sensor stemperature C F Notes 1 the recordingi...

Page 11: ...in AR232 B 9 4 BUTTONS FUNCTIONS AND ACCESS OPTIONS Table 9 4 Configurationparameters regarding buttonfunctions and access options Parameter Rangeofparametervariabilityanddescription Default settings...

Page 12: ...the Bluetoothparameter to be setto on value or programmingthe F button functionwith the Bluetoothturnon off value chapter 9 4 The recorder is visible under the name Smart Humigadget and can be connect...

Page 13: ...egligible Table 9 5 Configuration parameters regarding alarm configuration Parameter Rangeofparametervariabilityanddescription Default settings Alarmtypeforrelative humidity 1 and Alarmtypeforsensor s...

Page 14: ...ence number date time event identifier argument 1 argument 2 checksum Sample record for humidity and temperature measurement 20 2018 05 09 13 46 30 5 40 4 26 3 IEM1 where argument 1 40 4 RH argument 2...

Page 15: ...ood range with a connected mobile device and turnoff Bluetoothcommunication BLE when it is not used chapter 9 4 1 delete unnecessary files inthe internal memory before starting the new recording and c...

Page 16: ...r replace the battery with a newone of the appropriate type 3 6V AA chapter 4 with polarity in the holder screw the battery cover in place with the 2 screws with properly installed o rings NOTE when t...

Reviews: