background image

 
 

 

 

 

USER MANUAL 

 

 

                        

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       

AR236.B   

 

 

AR232.B

 

 

 

BATTERY - POWERED RECORDERS   

OF HUMIDITY AND/OR TEMPERATURE 

                     

 

 

                                                               

 

 

 

 

Version 2.0.4 

2019.03.13

APAR - SALES OFFICE

 

05-090 Raszyn, ul. Gałczyńskiego 6

 

Tel.           22 101-27-31, 22 853-49-30 
E-mail: [email protected] 
www: 

www.apar.pl

 

Summary of Contents for AR232.B

Page 1: ...6 B AR232 B BATTERY POWERED RECORDERS OF HUMIDITY AND OR TEMPERATURE Version 2 0 4 2019 03 13 APAR SALES OFFICE 05 090 Raszyn ul Ga czy skiego 6 Tel 22 101 27 31 22 853 49 30 E mail automatyka apar pl...

Page 2: ...E INSTALLATION 8 9 SETTING CONFIGURATION PARAMETERS 8 9 1 INTERNAL CLOCK OPTIONS 9 9 2 RECORDING OPTIONS 9 9 3 DISPLAY AND MEASUREMENTS OPTIONS 10 9 4 BUTTONS FUNCTIONS AND ACCESS OPTIONS 11 9 4 1 HAN...

Page 3: ...vice portable casingwith a handle for easy mounting on vertical and horizontal surfaces after using an additional table base or other user s solutions two line readable LCD display with icons and meas...

Page 4: ...u can also buy it through the online storeapar sklep pl 3 6V lithium battery type AA R6 2450mAh e g SAFT type LS14500 table base standing NOTE before working with the recorder read this user manual pe...

Page 5: ...etails inchapter 5 77x111x32 mm withoutprobe and hanging holder Operating position any positionor sensor cover down whenthe probe is exposed to directcontact with water Weight 150g withbattery and pro...

Page 6: ...r when condensation on the device is possible e g after taking out from the fridge Wait until the recorder reach ambient temperature to avoid potential malfunction If necessary during this time record...

Page 7: ...iconof the USB transmissionand recording readingof the recorder s memory 6 saving the archive file is active REC registrationstatus icon missing in progress or pause registration options are describe...

Page 8: ...ice from the computer before the installationof the drivers is completed connection of the recorder to the USB portof the computer stops the recordinguntil the cable is disconnected and blocks a previ...

Page 9: ...urry or late Dischargingand replacementor lackof battery causes the clock to be reset and requires setting time and date againafter the power is restored Table 9 1 Parameters of the internal time cloc...

Page 10: ...r calculated value dew frostpoint to besaved inthe archive file descry ptionoftherecord in chapter10 sensor s temperature C dew frostpointtemperature C F sensor stemperature C F Notes 1 the recordingi...

Page 11: ...in AR232 B 9 4 BUTTONS FUNCTIONS AND ACCESS OPTIONS Table 9 4 Configurationparameters regarding buttonfunctions and access options Parameter Rangeofparametervariabilityanddescription Default settings...

Page 12: ...the Bluetoothparameter to be setto on value or programmingthe F button functionwith the Bluetoothturnon off value chapter 9 4 The recorder is visible under the name Smart Humigadget and can be connect...

Page 13: ...egligible Table 9 5 Configuration parameters regarding alarm configuration Parameter Rangeofparametervariabilityanddescription Default settings Alarmtypeforrelative humidity 1 and Alarmtypeforsensor s...

Page 14: ...ence number date time event identifier argument 1 argument 2 checksum Sample record for humidity and temperature measurement 20 2018 05 09 13 46 30 5 40 4 26 3 IEM1 where argument 1 40 4 RH argument 2...

Page 15: ...ood range with a connected mobile device and turnoff Bluetoothcommunication BLE when it is not used chapter 9 4 1 delete unnecessary files inthe internal memory before starting the new recording and c...

Page 16: ...r replace the battery with a newone of the appropriate type 3 6V AA chapter 4 with polarity in the holder screw the battery cover in place with the 2 screws with properly installed o rings NOTE when t...