Product specifications and technical functions

1

Technical Specifications

Specification one

NO.

Basic parameter

1 Working voltage

DC8-24V

2 Working current

 50mA

3 Sampling time

About 1ms

4 Vibration

 1KHz

5 Noise

 5dB

6 Signal output

RS485(115200bps,8,1,n,n)

 20ms

Collector open circuit

<50V/100mA

7

Network port definition

1

2

3

4

5

6

9

7

8

White-orange/orange  White-blue

   Blue     White-green/green

White-brown Brown

VCC

RS485_B

RS485_A

GND

PE

NPN-C1

NPN-C2

8 Communication distance 

 300m

9 Alarm indication

LED

10 Threshold setting range

 ±5000V

11 Detection angle

 15°

12 Test plate size

600mm*600mm

13 Startup test time

5S

14 Infrared controlled range

 20°

1m

※  

Product specifications and performance may be changed due to product improvements and upgrades. Please refer to the actual product without prior notice.

 

2) The static voltage range and minimum resolution corresponding to each detection distance

Specification two

Detection 

gear

Distance 

coding

Detection 

distance 

Range   Resolution  Error Zero runout Calibration

1

0

5mm

±2000V

1V

10%

±1V

×

1

10mm

±4000V

2V

±2V

2

2

25mm

±20000V

10V

±10V

3

50mm

±20000V

10V

±10V

3

4

100mm

±20000V

10V

±10V

5

150mm

±20000V

10V

±10V

×

4

6

200mm

±20000V

10V

±10V

7

250mm

±20000V

10V

±10V

5

8

300mm

±20000V

10V

±10V

9

350mm

±20000V

10V

±10V

×

6

A

400mm

±20000V

10V

±10V

B

450mm

±20000V

10V

±10V

7

C

500mm

±20000V

10V

±10V

D

550mm

±20000V

10V

±10V

×

8

E

600mm

±20000V

10V

±10V

F

700mm

±20000V

10V

±10V

 Product specifications and performance may be changed due to product improvements and upgrades. Please refer to the actual product without prior notice. 

Unlock (unlock before debugging)

Customer use

SRZ

reset

V

TH

+/V

TH

-

Threshold adjustment in 10V unit

30s delay if any key is pressed after unlocking
Exit and re-locked if no key is pressed after unlocking

Product specifications and technical functions ...

3)

Infrared remote control command

technology function

Summary of Contents for AP-YV3303

Page 1: ...Intelligent Electrostatic Sensor AP YV3303 AP TR The second generation Shanghai Anping Static Technology Co Ltd Intelligent Electrostatic Sensor AP T ...

Page 2: ...tion distance can be selected by the DIP switch Adjustable Detection distance A closed loop monitoring and elimination system is formed by electrostatic sensing detection equipment electrostatic elimination equipment power supply equipment display equipment and IMS ionization monitoring system to realize automatic and unmanned electrostatic monitoring and elimination Closed loop Static electricity...

Page 3: ... and elimination system Terminal power Closed loop electrostatic detection monitoring and elimination system The closed loop electrostatic monitoring and elimination system formed by detection equipment elimination equipment power supply equipment display equipment and IMS Ionization Monitoring System can realize real time monitoring data storage and dynamic display under the control of system sof...

Page 4: ...ltage range and minimum resolution corresponding to each detection distance Specification two Detection gear Distance coding Detection distance Range Resolution Error Zero runout Calibration 1 0 5mm 2000V 1V 10 1V 1 10mm 4000V 2V 2V 2 2 25mm 20000V 10V 10V 3 50mm 20000V 10V 10V 3 4 100mm 20000V 10V 10V 5 150mm 20000V 10V 10V 4 6 200mm 20000V 10V 10V 7 250mm 20000V 10V 10V 5 8 300mm 20000V 10V 10V ...

Page 5: ...charged objects The measured value is smaller than the actual electrostatic value of the charged object when the charged object is smaller than the calibration plate The measured value is larger than the actual electrostatic value of the charged object when the charged object is larger than the calibration plate Do not adjust zero in the static charge state or in the electrostatic detection proces...

Page 6: ...onverter net weight about 20 5g The external dimension of the communication converter is as follows Nut Post 100 120 52 76 87 5 14 14 4 25 IMS Smart Controller WAN LAN P4 P3 P2 P1 POWER P1 P4 1 2 VCC 3 RS485_B 4 RS485_A 5 6 GND 7 C_VTH HVAL 8 C_ACT Clean 9 PE Metal shield P1 P2 P4 P3 Red VTH HVAL ACT Clean Green ACT Work Link NEXT SCAN NEXT LINK B SET S SCROLL T output port 24V DC 1 2 line output ...

Page 7: ... withstand voltage of the resistance should be 20KV the current passing through the protection resistance and the human body should be 5mA and the resistance value should meet the requirements of the following formula In the formula R is the protection resistance the unit is ohm Ω Rd is the resistance of the insulating support the unit is ohm Ω the resistance value is 1013Ω and the withstand volta...

Page 8: ...al test data chart of standard plate electrode The test is divided into vertical test and horizontal test The schematic diagram 9 of the sensor test device is as follows The vertical test data of the sensor and the standard plate electrode are as follows 10000 50000 5000 10000 10000 5000 0 5000 10000 Standard voltage slopeK 1 Test distance100mm Test distance300mm Test distance500mm The measured vo...

Page 9: ...e 600 600mm calibration plate It can be seen from the above two horizontal test charts that the measurement error of the sensor can be kept within 5 within the horizontal distance range of 200mm X 200mm under the vertical test distance of 300mm for the 600 600mm calibration plate It can be seen from the above two horizontal test charts that the measurement error of the sensor can be kept within 5 ...

Page 10: ...wer supply for comprehensive on line mode These three network ports of the 24V power adapter the monitoring terminal and the electrostatic sensor are both power ports and communication ports which can be used in common Connection to monitoring terminal Connection to PC IMS Smart Controller WAN LAN P4 P3 P2 P1 POWER P1 P4 1 2 VCC 3 RS485_B 4 RS485_A 5 6 GND 7 C_VTH HVAL 8 C_ACT Clean 9 PE Metal shi...

Page 11: ...ring software according to the withstand static voltage value of the protected product Note The threshold alarm indicator light is green when the detected static voltage value is within the set electrostatic threshold value while the light is red when it exceeds the set threshold value Use a Phillips screwdriver with a diameter of 3mm to turn the ADDR circular DIP switch to set the device address ...

Page 12: ...gh vibration area otherwise data errors may occur Please check the power cable or communication cable of the product regularly and replace it immediately if it is damaged Otherwise it will easily cause problems such as leakage of electricity poor communication and abnormal work It may cause failure when the product suffers from mechanical shocks such as drops bumps etc The whole equipment must be ...

Page 13: ... according to the use environment and static control requirements 5 Product has an odor Component burn out Return to factory for maintenance 6 Please contact the manufacturer or seller if there are other unlisted problems or the problem cannot be solved through the above solutions Trouble shooting 1 Please store the equipment in a dry place away from light and do not put heavy pressure on it when ...

Page 14: ...nitoring analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Address 3 F Building 27 No 69 Guiqing Road Shanghai China ...

Reviews: