Button function instructions
Unlock
Unlock before adjusting operating parameters
Run / Pause
Device starts running when power is on. Press "STOP" to standby and no high voltage
output. Press "RUN" again and the device will start working.
Parameter display
Unlock, press +/- to switch the display of working address/cleaning cycle, high-voltage
output duty cycle/frequency, working environment temperature/humidity, positive/negative
high-voltage alarm threshold, positive/negative high-voltage real-time output value
Adjust cleaning cycle
CTTH → +/-
Press CT
TH
first, then press +/- to increase or decrease the cleaning cycle (Default 30
days, adjustment range is 1-60 days)
Adjust alarm threshold
ALTH → +/-
Press AL
TH
first, then press +/- to increase or decrease the high voltage alarm threshold
(Default 1000V, adjustment range is 500-2000V)
Adjust duty ratio
PWM → +/-
Press PWM first, then press +/- to increase or decrease the duty ratio of positive high
voltage output to adjust ion balance
Adjust frequency
Press FREQ first, then press +/- to increase or decrease the high voltage output
frequency (set frequency switch cyclically) to adapt to different elimination distances
Calibration high pressure value
Press IBV first, then press +/- to increase or decrease the high voltage display amplitude
Adjust positive HV
Press IBP first, then +/- to increase or decrease the positive high voltage output
amplitude to adjust the discharge capacity and ion balance
Adjust negative HV
Press IBP first, then +/- to increase or decrease the negative high voltage output
amplitude to adjust the discharge capacity and ion balance
Confirm
CAL → OK
Press CAL first, then press OK to confirm after adjusting the output parameter
Reset
R
eset
,P
ress
CAL
first
,
then press
CAL →
→
+/-
Display information description
10.0
12.0
Display the real-time high-voltage output value of the high-voltage power supply
:
-10.0KV / +12.0KV
A00
E15
Display the working address of the high-voltage power supply / the cleaning cycle of the matching
ion bar
:
00 / 15
P50
F50
Display the duty ratio/frequency of the high-voltage output of the high-voltage power supply
:
50% / 50Hz
C19
H45
3.00
3.00
5
、
The output parameters of the high-voltage power supply can be set by the remote control, as shown in the table below:
Display the positive/negative high-voltage alarm threshold of the high-voltage power supply:
-3.00KV / +3.00KV
(eg
:
High voltage from 9KV 3KVAttenuation 6KV alarm)
Display the working environment temperature/humidity of the high-voltage power
supply
:
19
℃
/ 45%RH
FREQ → +/-
IBV → +/-
IBP → +/-
IBN → +/-