1. The fan should be cleaned and maintained in time according to the use environment and the required electrostatic protection requirements

in order to ensure the good performance of the product. That is, gently remove the dust on the electrode, discharge bracket, fan and metal

mesh cover with electrostatic brush, dust-free cotton swab, dust-free cloth dipped in anhydrous alcohol. Note:

A.  Operation must be done 10 minutes after power cut of

B. The cleaning cycle of the electrode needle should be set according to the working environment during use of the fan. It should be 

appropriately reduced in the environment with more humid and dusty.

C.  The fan must be powered on after alcohol is completely volatilized after cleaning. No other organic solvent can be used to clean the fa

D.  The alloy electrode is a consumable product which is not included in the scope of warranty and will be charged for replacement when 

repairing.

2. Do not press or rotate the control buttons on the fan panel too hard; otherwise, the device will be permanently damaged.

3. If the working indicator light on the front panel of the fan is off or red, it should be stopped and repaired by professional maintenance 

personnel. It can be used only after the electrical performance index is normal.

Maintenance

After-sales service

AP-DJ

2811

 ionizing air blower has undergone rigorous testing and aging treatment before ex-work. Its performance has completely reached 

the relevant indicators marked in the usage instruction.

AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge within one 

year from the date of purchase. However, this commitment does not apply to:

1.  The device is incorrectly used or installed.

2.  Damage caused by negligence or accident during use;

3. Modified, disassembled or repaired by other service departments not authorized by Anping Company.

AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.

Summary of Contents for AP-DJ2811

Page 1: ...Intelligent Control Network LED Display Ionizing Air Blower AP DJ2811 Shanghai Anping Static Technology Co Ltd AP TR AP T New Product Intelligent Control Network LED Display Ionizing Air Blower...

Page 2: ...ms caused by static electricity Suitable for electronics optoelectronics semiconductor and other industries Static removal Prevent blockage of feeder Prevent static electricity Prevent material splash...

Page 3: ...ring Monitoring the working status of ionizing air blower online RS485 communication AP DY6703 AP KT3701 AP DY6704 USB wire link USB wire link IMS monitoring software IMS monitoring software IMS monit...

Page 4: ...Button Function instructions Unlock Run Pause Clean Adjust clean time Adjust air volume Adjust ion balance Confirm Reset Unlock before adjusting operating parameters 30s delay if any key is pressed ex...

Page 5: ...of the object Increase Tp so that the positive voltage acting capacity becomes greater and the acting time becomes longer More positive ions and less negative ions output to neutralize the excess nega...

Page 6: ...he 0 point of the test length is the center position of the air blower Test standard ANSI ESD STM3 1 SJ T 11446 2013 Test instrument Trek charge plate tester Test voltage 1000V 100V attenuation Test e...

Page 7: ...ly brushed every 4 hours for manual cleaning and maintenance free Fault alarm Display screen show fault alarm and LED red light alarm when the fan ion balance and high voltage breakdown No 5 Network M...

Page 8: ...cing function The self balancing range is 10V and the balance voltage can be displayed in real time Intelligent remote control The negative high voltage amplitude is adjustable which can be used to ad...

Page 9: ...m Green light Running Blue light Pause Standby Blue light flashes Cleaning Red light Fan fault alarm Red light fashes HV alarm Product Use Panel functions specification dimensions Power interface cabl...

Page 10: ...pecification Installation accessories 1 pair of U shaped aluminum powder spraying mounting brackets 1 pair of bakelite screw handles M5 8 Unit mm Dimensions Model Input voltage Input voltage Output vo...

Page 11: ...ries 1 Place the ionizing air blower in the work area where static electricity is to be eliminated and the installation angle is perpendicular to the surface of the charged body 2 Ionizing air blower...

Page 12: ...Faults The indicator on the fan panel is off The electrostatic removal performance decreased obviously The electrostatic removal performance decreased High voltage ion balance alarm Panel indicator l...

Page 13: ...repairing 2 Do not press or rotate the control buttons on the fan panel too hard otherwise the device will be permanently damaged 3 If the working indicator light on the front panel of the fan is off...

Page 14: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...