AP&T AP-DJ1802 User Manual Download Page 5

Shanghai Anping Static Technology Co.,Ltd

Email:[email protected]

5

Security warning

1. Please read the instruction manual carefully before installing and using the device.

2. The whole set of equipment must be reliably grounded during use.

3. It is not advisable to use the device in a >70% humidity environment.

4. It is strictly forbidden to use this equipment in flammable and explosive environments.

5. It is strictly forbidden to disassemble the product without authorization. Internal maintenance and repair must

be carried out by professionals.

6. The product is strictly prohibited from touching water stains, otherwise abnormalities may occur, resulting in

electric shock or fire.

7. Check or replace the product, you must turn off the power, otherwise it may cause electric shock or fire.

8. The product is designed for static elimination. It is strictly forbidden to use for other purposes. Any abnormal

use may cause machine malfunction, electric shock, fire and other hidden dangers.

9. Do not touch the electrode needle when the power is on, otherwise it may cause malfunction and electric

shock.

10. The discharge needle is a sharp metal object, please use it with care.

11. Before powering on the product, please check the specifications of the power supply. Any power supply that

does not meet the specifications will cause damage or even malfunction.

12. Please check the product power cord/communication line regularly. If there is any damage, please replace it

immediately, otherwise it will cause problems such as leakage, poor communication and abnormal operation.

Use and installation

1, installation and use instructions:

(1) Select the best power-off position and install the fan and the matching power adapter firmly.

(2) Insert the adapter power cord round plug into the ion fan power socket, and insert the three-core power

socket into the socket.

(3) Close the power switch on the front panel of the ion fan. When the ion fan is turned on, it will automatically

brush the needle. When the indicator light is green, the fan will work normally.

2. External dimension drawing:

Summary of Contents for AP-DJ1802

Page 1: ...c Technology Co Ltd Email Nicole sh anping com cn 1 DC Ionizing Air Blower AP DJ1802 User Manual Shanghai Anping Static Technology Co Ltd 3 F Buliding27 No 69 Guiqing Road Shanghai China Tel 021 64517...

Page 2: ...cycle as shown below 7 with ion self balancing function self balancing range 10V 8 positive and negative ion output ratio adjustable can be used for ion balance adjustment 9 When the fan fails and th...

Page 3: ...rm the red light is always on 4 Abnormal ion balance red light flashes 5 Blue flashing during infrared debugging Communication method RS485 Operating temperature 0 50 Working humidity 70 RH Dimensions...

Page 4: ...9 7s 11 1s 0 3V 7 2s 10 2s 0 7V 3 6s 5 2s 0 7V 1 9s 2 6s 0 7V 0 7s 0 9s 2 4V 7 3s 9 0s 0 8V 11 2s 10 9s 1 2V 10 6s 11 9s 1 2V 300 300 300 300 300 300 5 4s 7 6s 0 1V 38 4s 60 4s 0 9V 26 4s 59 9s 0 0V...

Page 5: ...nction electric shock fire and other hidden dangers 9 Do not touch the electrode needle when the power is on otherwise it may cause malfunction and electric shock 10 The discharge needle is a sharp me...

Page 6: ...after pressing any button 7 After unlocking no button presses 30 to exit and lock 8 When the positive voltage of the surface of the flat panel detector or the object to be de energized is large press...

Page 7: ...ctromagnetic interference Turn off the power switch unplug the power cable restart the ion fan Abnormal discharge Confirm that the electrode needle is in contact with the metal conductor High voltage...

Page 8: ...el The user should not press or rotate excessively Otherwise the device will be permanently damaged 3 If the work indicator on the front panel of the fan is off or not lit it should be stopped and rep...

Reviews: