3. Specification
Model
AP-DC2451
Input voltage
AC 220V/50HZ or 110V/60HZ
Power
12W
Ion balancing
≤|±10V|(
300mm from blower
)
Discharge time
≤
2s
(
300mm from blower
)
Effective scope
600×1200mm
Air volume(Adjustable)
0~95 CFM
Noise
≤
45db
(150mm from air outlet)
Ozone thickness
≤
0.02 ppm (150mm from air outlet)
Working temperature
0°C - 50°C
Weight
1520g
Dimension
196
×
180
×
64
(
mm
)
4. Installation
When using AP-DC2451 ionizing air blower
,
the air transmitter
should be vertical to the object which static to be removed. The
trestle should be fixed on stable and plain surface such as wall by
screw and nut.
AP-DC2451 ionizing air blower should be put near working area
or 300~900mm to the objective. By screw the knob on both side
of the trestle the horizontal angle can be adjusted so that the
optimal effect of static removing can be achieved.
Installation instruction:
(1)Insert the power cord to the
power socket at the back
side of the blower.
(2)Switch on the power.
(3)Turn the air volume control
knob to proper value to
reach optimal effect.
Positioning
Desktop
vertical suspended
Oblique suspended Table clamping
5. Safety
(1) Be aware to read this user manual carefully before install and use
this device.
(2)Do not locate this device in the environment with high moisture.
(3)Do not insert any object into air input entry and output exit.
(4)Do not use this device in the flammable and explosive
surrounding.
(5)Internal maintenance and repairing must be done by professional
engineers.