background image

3. Specification

Model

AP-DC2451

Input voltage

AC 220V/50HZ or 110V/60HZ

Power

12W

Ion balancing

≤|±10V|(

300mm from blower

Discharge time

2s

300mm from blower

Effective scope

600×1200mm

Air volume(Adjustable)

0~95 CFM

Noise

45db

(150mm from air outlet)

Ozone thickness

0.02 ppm (150mm from air outlet)

Working temperature

0°C - 50°C

Weight

1520g

Dimension

196

×

180

×

64

mm

4. Installation

When using AP-DC2451 ionizing air blower

the air transmitter

should be vertical to the object which static to be removed. The
trestle should be fixed on stable and plain surface such as wall by
screw and nut.
AP-DC2451 ionizing air blower should be put near working area
or 300~900mm to the objective. By screw the knob on both side
of the trestle the horizontal angle can be adjusted so that the
optimal effect of static removing can be achieved.

Installation instruction:

(1)Insert the power cord to the

power socket at the back
side of the blower.

(2)Switch on the power.
(3)Turn the air volume control

knob to proper value to
reach optimal effect.

Positioning

Desktop

vertical suspended

Oblique suspended Table clamping

5. Safety

(1) Be aware to read this user manual carefully before install and use

this device.

(2)Do not locate this device in the environment with high moisture.
(3)Do not insert any object into air input entry and output exit.
(4)Do not use this device in the flammable and explosive

surrounding.

(5)Internal maintenance and repairing must be done by professional

engineers.

Reviews:

Related manuals for AP-DC2451