source. Adjust the pressure controller to proper value to
reach the optimum effect.
Air gun should be close to the working area (appro. 150-300mm
to the target objective) when using. Air exit must aim to the
target objective. By adjusting the input air pressure and gun
angle could reach the optimum static removing effect.
5. Maintenance
(1)
Take off the air cap in front of the air gun and observe the
head of the alloy electrode. Change the electrode when it
becomes obtuse while not sharp to guarantee the
effectiveness of the static removing.
(2)
If the indication light keep off user should stop operating the
device and ask for maintenance. Device can only be used
when the generator is under normal condition.
(3)
Lubricant should be appended regularly to keep air source
switch smooth.
6. Safety
(1)Be aware to read this user manual carefully before install
and use this device.
(2)Do not locate this device in the environment with high
moisture.
(3)Do not use this device in the flammable and explosive
surrounding.
(4)
Earth wire of the air gun and power generator should be
connected reliably to guarantee the user safety.