16
LINE FREQUENCY SELECTION
M. Line Frequency Selection
By default, the system's line frequency has been programmed from the
factory but for some cases when a manual override of the line frequency is
needed the following procedure can be done.
1. Follow System Setting procedures 1 to 6. Adjust system selection
menu to Set 007,
then turn the hot air gun set temperature knob
to off position.
2. If successful the display “B1” “-60-” indicating frequency is being set.
3. Adjust the frequency adjustment knob “B3” to enter desired frequency
value, Value is switchable between 60 or 50 Hz.
4.
Save the selected calibration settings and exit from the calibration
adjustment menu
by turning the soldering iron set temperature
knob to off position.
Soldering Iron Tip
Always keep the solder-plated section of the tip/nozzle coated with a small
amount of solder. Oxide coating on the tip of the nozzle reduces its heat
conductivity. Coating the tip with a small amount of fresh solder ensures
maximum heat conductivity is obtained.
Soldering Iron Error Messages
When soldering iron connection assembly is not connected or not properly
connected to the receptacle on the control panel or when soldering iron tip is
damaged and needs to be replaced. The device will display “Err 1”. indicating a
problem with the contacts of the soldering iron or the tip.
CARE and MAINTENANCE