background image

Ÿ

APP

Click

 

history

 

can

 

check

 

the

 

history

 

route

.

3.8

 

Geo-Fence Alarm (IN/OUT Area)

Ÿ

Web

 

platform

 : 

Click

 "

fence"and

 

select

 "

new

 

circle

 

fence"or

 "

new

 

polygon

 

fence"

,

can

 

draw

 

a

 

invisible

 

fence

,

when

 

device

 

out

/

in

 

the

 

fence

,

platform

 

will

 

show

 

alarm

Ÿ

device

 

out

/

in

 

the

 

fence

,

platform

 

will

 

show

 

alarm

.

APP 

: Click

 "

location"and

 

select

 

more

 

functions

 -

add

 

new

 

fence

 

or

 

select

 

fast

 

fence

 ,

when

 

3

.

9

 

Ÿ

Web

 

platform

 

Click

 "

Settings

"

can

 

set

 

the

 

different

 

alarm

 

switch

.

Ÿ

Set

 

over

 

speed

 

threshold

 

Free

 

to

 

set

 

in

 

any

 

speed

.

Multiple Alarming

Check

 

the

 

total

 

alarms

 

:

 

Click                in

 

the

 

upper

 

right

 

corner

 

can

 

check

 

all

 

notifications

.

Ÿ

Ÿ

Setting

 

Over

 

speed

 

alarm 

:

 

Click

 "

config" 

set

 

speeding

 

value

-

config

Ÿ

Check

 

alarms 

:

 

Click

 

"Notify"         to

 

view

 

the

 

relevant

 

alarm

 

information

,

as

 

shown

 

in

 

Figure

 

6

 

below.

 

APP 

:

 

Click

 "

Manage"          can

 

set

 

the

 

different

 

alarms

 

switch

.

The "notify" shows the total alarms of the device , the product has a tamper / light / low 
power / vibration / displacement / over speed alarm, etc., in the Web or APP to select the 
appropriate alarm to remind the switch.

(1) Low power alarm

: When the internal battery voltage is lower than 3.6V, will 

automatically send an alarm to the platform.

(2) Tamper alarm

: When the equipment tamper switch is detected to be removed, it will 

automatically send an alarm to the platform.

(3) Light alarm

: equipment installed in the dark, when the device in the photoresistor to 

detect the light, it will automatically send an alarm to the platform.

(4) Displacement and vibration alarm

: When the device senses that the vehicle is 

abnormally vibrated or is illegally moved, it will automatically send an alarm to the 
platform.

(5) Over speed alarm

: speed alarm to set the speed threshold, when the device speed 

exceeds the threshold, it will automatically send an alarm to the platform. The default 
speed threshold is 120km / h, and 0 indicates the overspeed alarm is off.

3

.

10

 

Set

 

GPS

 

uploading

 

interval

The

 

GPS

 

default

 

uploading

 

interval

 

is

 

30

 

seconds

,

you

 

can

 

set

 

the

 

minimum

 

to

 

10

 

seconds

 , 

and

 

it

 

will

 

uploading

 

more

 

frequently

 

and

 

correspond

 

will

 

cost

 

more

 

battery

 

and

 

GPRS

 

data

.

Ÿ

Web

 

platform

 :

 

Click

 "

Settings”-Set

 

GPS

 

upload

 

time

 

interval.

Ÿ

  

APP: 

Click

 "

Manage"-"config"

-

Set

 

GPS

 

upload

 

time

 

interval.

4. Modes

The T802 can auto-change the working mode in different situations.

Tracking

 

Mode

Device

 

stopped

Sleeping

 

Mode

Upload

 

location

 

data

 

to

 

platform

 

each

 

30

 

seconds.

Detect

 

vibration

 

or

 

movement

Start

 

Moving

Device

 

was

 

stop

 

over

 

3

 

minutes

In

 

this

 

two

 

mode

,

user

 

can

 

send

 

command

 

via

 

platform

&

APP

 

or

 

SMS

 

to

 

the

 

device

.

GPS

 

offline

 ,

GPRS

 

keep

 

connecting

,

Uploading

 

a

 

data

 

to

 

platform

 

every

 

3

 

minutes.

Supplement

:

*

Each

 

time

 

the

 

device

 

wakes

 

up

 

from

 

a

 

low

-

power

 

mode

it

 

will

 

perform

 

AGPS

 

fast

 

positioning

If

 

the

 

network

 

abnormality

 

causes

 

the

 

AGPS

 

to

 

fail

it

 

will

 

try

 

several

 

times

.

*

If

 

the

 

satellite

 

positioning

 

fails

the

 

device

 

will

 

upload

 

base

 

station

 

location

 

data

 

to

 

the

 

server

base

 

station

 

positioning

 

accuracy

 

is

 

lower

 

than

 

the

 

satellite

 

positioning

.

8. Trouble Shooting

è

T802 is offline? 

Solutions: call T802, if it does not answer:
Please confirm that the power supply is connected, and the GSM indicator is lighted.
Please confirm that the SIM card is inserted correctly or its balance is enough.
If it answered, please confirm that the account you logged in is correct.
If it is still offline, please restart the T802

.

è

GPS positioning is not accurate?

Solution: Please confirm T802 is in outdoor environment, and GPS antenna is not blocked 
by metal objects.
The positioning accuracy of GPS is about 10 meters. If the positioning is not so accurate, 
the T802 may be in indoor place. If the GPS signal is weak, the Cell-ID positioning would 
enable. The positioning accuracy about 10~30m of Cell-ID is usually worse than that of 
GPS. You can enable or disable the Cell-ID positioning in the platform.

è

Can not remotely listen?

Solutions:
Please confirm that the SIM card in the T802 has the voice call function.
Please confirm that the listening function of T802 is enabled.

è

Not this IMEI or User Name?

Solution: Please contact with our service staff, they will add your account into the system

.

9. Service

 

and

 

Warranty

è

è

è

è

m

m

m

m

You can return or change the product if the damage occur at performance within 7 days.
It is free to repair the product within a year if the damage are not manually.
Please show the Warranty Card and do not alter it when you want to get relation help. If not, 
we reserved the right of no warranty.
We will provide the warranty service with no free in the following cases

Damaged T802 by human factors.
Damaged by mis-wiring.
Damage caused by force majeure, such as Natural fire, lightning.
Mis-operation without reading this manual.

5. SMS Commands 

Commands Name

Commands

  

Contents

Set guardian number

sos,

xxxxxxxxxxx

Sending

 

SMS

 

to

 

inquiry

C

Parameters

 

inquiring

SR

CLOSE,

 

N1

Enable

/

disable

 

SMS

 

alarm

 

DH,

 

N1

Enable

/

disable

 

calling

 

alarm

 

xxxxxxxxxxx---the guardian number

Note: if the guardian number

 

is

 

null

it

 

is

 

meant

 

to

 

clear

 

the

 

guardian number

Sending

 

SMS

 

to

 

inquiry

 

the

 

current

 

position

Inquiry

 

the

 

parameters

 

of

 

T802

N1

means

 

if

 

the

 “

SMS

 

alarm”

 

function

 

is

 

enabled

 

or

 

not

N1=1” means

 

disabled

, “

N1=0”means

 

enabled

— 

N1

means

 

if

 

the

 “

call

 

to

 

alarm”

 

function

 

is

 

enabled

 

or

 

not

N1=1” means

 

enabled,

 “

N1=0”means

 

disabled

— 

Explanations

JGBJ

,

N1

,

N2

,

N3

Light

 

detected

 

alarm

1

2

3

4

5

6

NO

ZD,N1,N2,N3

Vibration

 

alarm

 

setting

Low

-

power

 

alarm

 

setting

DY,N1,N2,N3

10

DY

set

 

low

-

power

 

alarm

N1

 

means

 

if

 

the

 “

low

-

power

 

alarm”

 

function

 

is

 

enabled

 

or

 

not

     “

N1=1” means enabled, “N1=0” means disabled

N2

 

means

 

if

 

the

 

SMS

 

function

 

of

 

low

-

power

 

alarm

 

is

 

enabled

 

or

 

not 

     “N2=1” means enabled, “N2=0” means disabled
N3—

 

means

 

if

 

the

 

Call

 

function

 

of

 

low

-

power

 

alarm

 

is

 

enabled

 

or

 

not 

     “N3=1” means enabled, “N3=0” means disabled

— 

ZD---set vibration alarm
N1--- means if the “vibration alarm” function is enabled or not
     “N1=1” means enabled, “N1=0” means disabled
N2--- means if the SMS function of vibration alarm is enabled or not 
     “N2=1” means enabled, “N2=0” means disabled
N3--- means if the Call function of vibration alarm is enabled or not 
     “N3=1” means enabled, “N3=0” means disabled

7

CSBJ--- set overspeed alarm
speed---the upper limit value of speed, with a range in 40-60km/h.   
       It also can be 0. “0”means the overspeed alarm is disabled
n1 means if the SMS function of overspeed alarm is enabled or not 
     “n1=1” means enabled, “n1=0” means disabled
n2 means if the Call function of overspeed alarm is enabled or not 
     “n2=1” means enabled, “n2=0” means disabled

CSBJ,speed,
n1,n2

Overspeed alarm 
setting

8

9

15

WLSMS,N1

Geo

-

fence

 

alarm

 

setting

WY,N1,N2,N3

Displacement

 

alarm

 

setting

N1

means

 

if

 

the

 “

Geo

-

fence

 

alarm”

 

function

 

is

 

enabled

 

or

 

not

     “

N1=1” means

 

enabled

, “

N1=0”

 

means

 

disabled.

— 

WY

set

 

displacement

 

alarm

N1

 

means

 

if

 

the

 “

displacement

 

alarm”

 

function

 

is

 

enabled

 

or

 

not

     “

N1=1” means enabled, “N1=0” means disabled

N2

 

means

 

if

 

the

 

SMS

 

function

 

of

 

displacement

 

alarm

 

is

 

enabled

 

or

 

not 

     “N2=1” means enabled, “N2=0” means disabled
N3—

 

means

 

if

 

the

 

Call

 

function

 

of

 

displacement

 

alarm

 

is

 

enabled

 

or

 

not 

     “N3=1” means enabled, “N3=0” means disabled

— 

14

Note

:

è

N1

/

N2

/

N3

 

must

 

be

 

equal

 

to

 

0

 

or

 

1

è

Except setting the guardian number command, other commands can only be issued by 

the guardian number.

è

For

 

example

CSBJ,60

,

0

,

1 indicates that it

 

will

 

make

 

an

 

call

 

alarm

 

of

 

overspeed

 

when

 

the

 

speed

 

exceeds

 

60km

/

h

DY,1,1,0

 

indicates that it

 

will

 

make

 

a

 

SMS

 

alarm

 

of

 

low

 

power

 

when

 

the

 

T802

s

 

power

 

is

 

low

.

12

ITV--- set

 

transmission

 

time.

N1---the

 

specified

 

time

 

value

 

of transmission

with

 

a

 

range

 

in 

15-3600s

.

ITV,N1

GPS

 

uploading

 

interval

 

Reset

 

all

 

settings

 

to

 

factory

 

except

 

the

 

IP

 

address

 

and

 

port

 

of

 

server

.

CLEAR

Reset

 

to

 

factory

Restart

 

T802

RESET

Restart

 

the

 

T802

11

19

24

16

18

23

28

16

21

26

17

22

19

27

JGBJ

 --- 

light

 

alarm

 

setting

 

N1

 --- 

light

 

alarm

 

function

 

is

 

turned

 

on

 

or

 

off

Valid

 

values

 

are

 

0

 

or

 

1

,

0

 

for

 

off

1

 

for

 

on

N2

 --- 

light

 

alarm

 

corresponding

 

to

 

the

 

SMS

 

alarm

 

notification

 

is

 

turned

 

on

 

or

 

off

Valid

 

values

 

are

 

0

 

or

 

1

,

0

 

for

 

off

1

 

for

 

on

N3

 --- 

light

 

alarm

 

corresponding

 

to

 

the

 

telephone

 

alarm

 

notification

 

is

 

turned

 

on

 

or

 

off

Valid

 

values

 

are

 

0

 

or

 

1

,

0

 

for

 

off

1

 

for

 

on

Alarm status 
inquiring

ALMSW

Inquiry if the alarm is enabled or not

GPS sleeping 
setting

sleep,N1

Sleep---Set sleeping of GPS
N1---means if the “GPS sleeping” function is enabled or not

N1=1” means enabled, “N1=0” means disabled

6.Default

 

settings

6.1

 

Basic

 

parameters

 

are

 

set

 

by

 

default

Default item 
guardian(SOS) number 
Sleeping model switch 
SMS Alerts switch 
Call alarm switch 
Vibration alarm sensitivity 
Over speed alarm threshold 
Uploading interval 
Fortify function(vibration ,movement )

Status 
Empty 

On 
Off 
Off 

Low 

120km/h

30 seconds 

Off 

6.2

 

Separate

 

alarm

 

switch

 

default

 

setting

There

 

are

 

three

 

kinds

 

of

 

alarm

telephone

platform

 

three

 

alarm

 

methods

each

 

alarm

 

supports

 

one

 

or

 

more

 

different

 

alarm

 

mode.

Note

To

 

achieve

 

the

 

telephone

 / 

SMS

 

alarm

 

function

 

to

 

open

 

the

 

phone

 / 

SMS

 

alarm

 

switch

Alarms type
Low power 
Anti remove 
Light alarm 
Geofence alarm 

 

(

Platform

)

switch 

On 
On 
On 
On 

SMS switch 

Off 
Off 
Off 
Off 

Call switch 

Off 
Off 
Off 
Off 

NO.

1
2
3
4

15

20

25

7

Parameters

Items

GSM frequency

BDS/GPS chip

GPRS

Sensitivity of BDS/GPS

BDS/GPS Accuracy

Cell ID Accuracy
Speed Accuracy

A-GPS Start-up

Fast Positioning

3D G-Sensor

Battery

Storage Temperature

Operating Temperature

Humidity

Operating Current

Sleeping Current

Dimensions
Net Weight

NO

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18

Value

850MHz/900MHz/1800 MHz/1900 MHz

Compatible with u-blox/BDS

Class 12,TCP/IP build in GSM MODULE

-163dBm

10m (open sky)

50-2000m

0.1m/s

≤25s (open sky)

Supports AGPS

±8g(All Direction)

6000mAh/rechargeable 

-40~+85

C

-20~+70゜C

20%~80%RH

< 50mAh

< 3.5mA

62*120*25mm

223g

13

WARRANTY CARD

Name

Purchase Date

Contact

 

Email 

Address 

Dealer's Stamp

Please send this warranty card to 
M3 Asia Sdn Bhd
Lot 17.1, Level 17,Menara Lien Hoe,Persiaran Tropicana,47410

Petaling 

Jaya,Selangor,Malaysia or email to support @m3asia.com. 
Tel No.03-7886 2423 Web:www.m3asia.com