- LEVEL-SQUELCH
DBnnn
W
DBnnn O nnn = 000 - 255 (Default is 000 for off)
THRESHOLD
This command can be applied to VFO, MEMORY
and SEARCH DATA
When the optional Remote Control Panel is
connected, the AF-volume must be turned to
minimum for the command to function.
DB
R
DB nnn
- AF-GAIN
AGnnn
W
AGnnn O nnn = 000 - 255 (Default is 255)
When the optional Remote Control Panel is
connected, the AF-volume must be turned to
minimum for the command to function.
AG
R
AG nnn
- MANUAL-GAIN
MGnnn
W
MGnnn O nnn = 000 - 255 (Default is 255)
AGC must be set to OFF.
MG
R
MG nnn
- SELECT SQUELCH
SQn
W
n = 0 O NOISE-SQ (DEFAULT)
n = 1 O LEVEL-SQ
SQ
R
SQn
- SIGNAL-LEVEL
LM
R
ATn AMn NSQm LMnnn O When NOISE-SQ is
selected ( nnn = 000 - 999 )
ATn AMn LSQm LMnnn O When LEVEL-SQ is
selected ( nnn = 000 - 999 )
m = 0 O SQUELCH closed
m = 1 O SQUELCH open
- AUTO SIGNAL
LCn
W
n = 0 O OFF
LEVEL
n = 1 O ON ( When the squelch opens, signal
level and frequency are returned )
LC
R
LCn
R
SQm LCnnn RFnnnnnnnnnn
m = 0 O When NOISE-SQ is selected.
- SCAN/SEARCH
SGn
W
When scan/search is in operation: when it stops,
the squelch opens and closes again. Then
RE-START CMD
scan/search resumes . This SG command repeats
the process.
n = 0 O NO-OPERATION
n = 1 O Re-starts [SG]
SG
R
SGn