Set DMX Address 

Click and select the "ADDR", can enter the page of DMX address setting, range from 1 to 512, the 

address  code  shouldn’t  is  not  greater  than  (512

-  channels  quantity),  otherwise  the  light  will  not 

been controlled. Following is the operation:   

Enter the page of DMX address, click the blank area in right side of display will pop-up diglog as in 

Fig. 4, modify value, then click ‘ENTER’ to confirm and save DMX address code.

 

6.2 Address Setting 

If you use a universal DMX controller to control the units, you have to set DMX address from 1 

to 512 

so that the units can receive DMX signal. 

Press the MENU button to enter menu mode, select DMX Functions, press the ENTER button 

to confirm, use the UP/DOWN button to select DMX Address, press the ENTER button to confirm, 

the present address will blinking the display, use the UP/DOWN button to adjust the address from 

001  to  512,  press  the ENTER  button  to  store.  Press  the  MENU  button  back  to  the  last menu  or 

idling let the unit idle one minute to exit menu mode. 

Please refer to the following diagram to address your DMX512 channel for the first 4 units. 

Channel mode 

Unit 1 
Address 

Unit 2 
Address 

Unit 3 
Address 

Unit 4 
Address 

26 

27 

53 

79 

 

6.3 DMX 512 Configuration 

Please refer to below configurations to control the fixtures 

Attentions: 

1. The unit will maintain the last condition until reset if you cut-off the DMX signal. 

2. For the channel Function, keep the value for about 5 seconds, then the corresponding function 

will take into effect. 

 

 

 

26Channels (Mode 1): 

CHANNEL1 

Designation

 

Value 

FUNCTION 

CH1 

PAN 

0-255 

Pan 

 

0° - 540° 

CH2 

PAN FINE 

0-255 

Pan Fine 

 

Fine Pan positioning 

6/12 

Summary of Contents for AL400RX

Page 1: ...380W 3IN1 Moving Head User Manual Please read the instruction carefully before use...

Page 2: ...3 1 Control Panel 4 2 Light Source 5 How To Set The Unit 5 1 Main Function 5 2 Home Position Adjustment 5 3 Error Information 6 Control By Universal DMX Controller 6 1 Connection 6 2 Address Setting...

Page 3: ...at the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Ambient temperature...

Page 4: ...an lead to damage or malfunction Please contact the nearest authorized technical assistance center if needed Disconnect the mains power if the fixture is has not been used for a long time DO use the o...

Page 5: ...lay 2 8 inch touch color LCD display Chinese and English display can be reversed display Weight 23Kg Dimension 667 335 393mm 3 Description 3 1 Control Panel Front view Rear view 1 Function Display Sho...

Page 6: ...ng When the selected item is value need to been modified the dialog shown in will popup Modify value Can quickly modify value via pull the slider to the desired position or click the button of up or d...

Page 7: ...n in auto run mode DISPLAY Set display parameter eg select language TEST Used for test light modify DMX channel data to test function the corresponding function of reference channel function table ADV...

Page 8: ...select DMX Address press the ENTER button to confirm the present address will blinking the display use the UP DOWN button to adjust the address from 001 to 512 press the ENTER button to store Press th...

Page 9: ...ear adjustment from light to dark for Yellow CH10 COLOR1 000 127 Linear color 128 148 Open 149 169 Color 1 170 191 Color 2 192 212 Color 3 213 233 Color 4 234 255 Color 5 CH11 COLOR2 000 127 Linear co...

Page 10: ...199 Gobo13 shaking slowto fast 200 201 Empty position 202 227 Continuous gobo wheel clockwise rotation at Linearly variable speed from fastto slow 228 229 Stop rotation 230 255 Continuous gobo wheel...

Page 11: ...tion 193 255 Continuous gobo wheel counter clockwise rotation at linearly variable speed from slow CH17 PRISM 0 63 Prism out 64 127 Prism 1 into the light beam 128 191 Prism 2 into the light beam 192...

Page 12: ...The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED to see if it can be light u...

Page 13: ...er B 3 Loosen the screws C that fix the bridge 4 Change a new belt D Please adjust the tension of the belt properly Note do not fix the belt too tight as it is can easily rupture 5 Reverse the procedu...

Page 14: ...s optics Clean with soft cloth and use normal glass to clean liquid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days...