In

air

Vacuum

Pump

air

out

Signal Indicator

Indication

Next Action

c.

d.

e.

f.

g.

Slow Blinking BLUE

 (1 time/sec)

Ready for Vacuum analyzation 

Vacuum Pumping

Blinking YELLOW

Vacuum below desired level

Continue pumping

Blinking alternate 

YELLOW - RED 

Vacuum above desired level

Twist the Vacuum Release Tip 

counter-clockwise

Still YELLOW

Vacuum analyzation in progress

Wait for 4 minutes for vacuum analyzation

Blinking RED

Vacuum analyzation test has Failed

Inspect the housing for

any potential air leakage sources

Steady RED

with audible alarm

Wet Sensor Strip detects

water droplet or moisture

Inspect the housing for

any potential water leakage sources

Slow Blinking GREEN  Vacuum analyzation test has Passed Ready for going into water

Using the Housing and Camera after testing passed

2. Perform Water Leakage Test

Connecting the Fiber Optic Cable

a.

b.

Removing and Replacing the housing Lens Port

a.

b.

Care and Maintenance

Specifications

a.

b.

c.

d.

e.

f.

g.

h.

a.

AOI UH-EPL10 Expansion Pathway

b.

*

c. To install the Port Lens, align the Lens Port Alignment Marks on the Lens Port and the 

Housing Body and then push the Lens Port completely down into Housing Body. Turn 

the Lens Port clockwise until a “Click” sound is heard. When the Port Release Button 

is no longer depressed, the Lens Port is properly installed and locked.

c.

a.

b.

Pre-checking before Diving

Table 2

AOI

 

LUMIX  8mm 

F3.5 FISHEYE

LENS 

CATEGORY

OLYMPUS / AOI

OLYMPUS

M.ZUIKO DIGITAL

  

ED 9-18mm

F4.0-5.6

M.ZUIKO DIGITAL 

 

ED 8mm

F1.8 FISHEYE

PRO

M.ZUIKO DIGITAL

  

ED 14-42MM

F3.5-5.6 EZ

 

M.ZUIKO DIGITAL

  

 

ED 12-50mm

F3.5-6.3 EZ

 

 

ER_PN_PN-24

ER_PN_PN-34

ER_PN_PN-24

ER_PN_PN-24

ER_PN_PN-34

FLP-04

FLP-06-GRY

DLP-03 / 03P / 04 / 04P

DLP-05 / 06

DLP-05 / 06

FLP-04

UCL-09

UCL-900

UCL-900PRO

UWL-09

UWL-09PRO

UCL-09

UCL-900

UCL-900PRO

FLP-06-GRY

WIDE ANGLE

LENSES

SUPER WIDE

ANGLE LENSES

FISHEYE

LENSES

MACRO

LENSES

AOI

LG-OM-1442EZ

AOI

LG-OM-1250EZ

OLYMPUS

PPZR-EP02

OLYMPUS

PPZR-EP05

POSR-EP10

POSR-EP11

FLP-04

FLP-02

FLP-04

FLP-06-GRY

Antireflective Ring

POSR-EP02

 

 

M.ZUIKO DIGITAL

ED 60mm

F2.8 MACRO

 

M.ZUIKO DIGITAL

  

ED 30mm

F3.5 MACRO

 

PPZR-EP07

OLYMPUS

PPZR-EP03

OLYMPUS

CAMERA

LENSES

GEARS

ANTIREFLECTIVE

RINGS

PORTS

EXTENSION

RINGS

WET

LENSES

(xiv)

(xv)

(xvi)

(xvii)

(xviii)

(xix)

(xx)

- 9 -

- 10 -

- 11 -

- 12 -

- 13 -

- 14 -

- 15 -

- 16 -

Power on the Multi-control Device and if the Signal Indicator shows Blinking BLUE 

(1 time/sec), that means the Vacuum Analyzation and Wet Detection Sensor is on 

standby mode. Ensure camera is off, close the Rear Cover according to the steps 

described in “Installing camera into the housing”. 

Take off the Protection Cap from the Vacuum Valve and connect the Vacuum Pump 

onto the Vacuum Valve Tip. Pull and Release the Vacuum Pump handle gently and 

repeatedly  for  Vacuum  Pumping.  During  the  Vacuum  Pumping  process,  check 

carefully for changes in color on the Signal Indicator.

Color Codes Indication:

Fast Blinking YELLOW  

Internal pressure has started to drop. Continue to pump.

Slow Blinking YELLOW  

Internal vacuum level is close to the desired value. Slow down pumping.

Still YELLOW 

Internal vacuum level has been reached. Stop pumping and the Vacuum

Analyzation Process will be started automatically.

Blinking alternate YELLOW & RED 

Internal  vacuum  level  is  above  the  desired  value.  Stop  pumping  and  carefully 

release air by gently twisting the Vacuum Release Tip counter-clockwise slightly 

until the Signal Indicator turns to Still YELLOW. If too much air is released into the 

housing,  the  Signal  Indicator  will  change  back  to  Blinking  YELLOW  again. 

Resume vacuum pumping until Signal Indicator turns to Still YELLOW.

Once Vacuum Analyzation is completed successfully and Vacuum Valve Protection Cap 

is secured, review the housing further by checking for water leakage. Submerge it in a 

shallow  tub  of  water  or  rinse  tank.  While  submerged,  activate  all  the  control  buttons, 

control switches, and control knobs in order to have a dynamic test to prove all the sealed 

moving parts are water sealed properly. If there is no water droplet observed inside the 

housing after Underwater Dynamic Test, it means the housing is fully watertight. If water 

leaks  into  the  housing,  the  water  droplets  will  be  detected  by  the  Wet  Sensor  Strip 

located in the lowest part of the housing. Signal Indicator will turn Still RED and audible 

alarm “BEEP-BEEP-BEEP” will be heard.

Please ensure that the Vacuum Valve Cap is in place and completely closed.

When using the housing, make sure that it is properly secured to you and accessories 

are properly secured to the housing. 

Do not exceed the housing maximum depth rating of 45 meters (148 ft.) 

If the Wet Detection alarm is triggered during use, it means water has entered into the 

housing. If that happens, try to position the housing lens port facing down and exit the 

water safely in accordance with diving procedure and regulation. Upon returning to 

land, remove the camera from the housing. If only a few droplets of seawater entered 

the housing, thoroughly wipe off the seawater droplets with a moist towel and dry the 

inside of the housing thoroughly with tissue paper. 

If seawater leaked into the housing and the Multi-control Device is flooded, take out 

the camera, rinse the housing cavity thoroughly with running fresh water for a few 

minutes. Then, dry the housing cavity completely and bring it to your local dealer for 

servicing immediately.

a.

b.

c.

d.

e.

Rinse  the  housing  exterior  thoroughly  with  running  fresh  water  after  every  use. 

Depress buttons and rotate knobs/dials repeatedly in fresh water to eliminate trapped 

salt water or debris. Dry the housing and Lens Port with a soft, clean cloth to avoid 

water spotting and damage.

To clean the Lens Port Glass, use a mild soap solution or lens cleaner. Do not rinse 

the inside of port glass. Do not use alcohol or window cleaner on the Lens Port Glass.

In order to better inspect, position, clean or lubricate the Housing Main Seal O-ring or 

Lens Port O-rings, carefully remove the required O-ring by using the provided AOI 

O-Ring Remover/White Balance Card.

Clean  the  O-ring  and  the  O-ring  groove  by  using  a  microfiber  cloth  only.  Use  AOI 

O-Ring  Remover/White  Balance  Card  to  clean  the  O-Ring  groove.  Do  not  use 

cleaning substances other than fresh water. Remove sand, dirt, hair or fibers that can 

prevent a proper housing seal.

To lubricate O-rings, apply a small amount of silcone grease (

AOI SIGR-5

) on your 

fingertips, gently pull the O-ring through the fingertips. This will lightly coat the entire 

O-ring  with  silicone  grease.  Only  use  the  AOI  Silicone  Grease  supplied  or  those 

approved by AOI. Using other brands of silicone grease may damage the O-ring. Do 

not over stretch the O-ring.

Do not leave the camera and housing in direct sunlight for prolonged periods. Heat 

may damage the camera and housing.

Dry well and remove the camera prior to travel and storage.

Store the housing in a cool and dry place.

IMPORTANT: 

 Wipe the housing dry and keep water away prior to opening the housing. 

Do  not  allow  water  to  be  in  contact  with  the  interior  of  the  housing.  This  will  cause 

irreparable  damage  to  the  Vacuum  Analyzation  and  Wet  Detection  System  and  other 

electronic/electrical components!

IMPORTANT: 

 Rinse the Fiber Optical Cable Ports with running fresh water after every 

use, then let it dry naturally. Do not dry inside of the ports with any tool, this may result in 

scratches and reduce the capacity of the optical signal transfer.

The housing is pre-installed with an Optical Flash Trigger in the Multi-control Device. 

This feature prolongs the camera battery life by not using the built-in camera flash to 

trigger the external underwater flash or strobe. The housing is equipped with two Fiber 

Optic Cable Ports and they are compatible with AOI Fiber Optic Cable with SS cable 

plug or other fiber optic cable brands using the standard Sea & Sea plug.  

Insert one end of the fiber optic cable into the Fiber Optic Cable Port of the housing 

(fig. xv) and then insert the other end into the fiber optic cable port on the external 

flash or strobe.

The flash trigger signal (electrical signals) will be transferred from the camera Hot 

Shoe to the Multi-control Device through the Hot Shoe Connector (included in the 

package).  The  Optical  Flash  Trigger  in  the  Multi-control  Device  will  convert  the 

electrical flash triggering signal into an optical signal and then will deliver it to the Fiber 

Optic Cable. The Fiber Optic Cable (not included in package) picks up the optical 

signal and delivers it to the external flash or strobe.

The Optical Flash Trigger is only compatible with multi-core fiber optic cables, please 

ensure that the fiber optic cable used is compatible. 

The Optical Flash Trigger LED is not easily visible when fired as it is not very bright, 

so it is difficult to check whether or not the LED is being triggered.

NOTE:

The Vacuum Analyzation Process will start automatically once the Signal Indicator 

turns Still YELLOW. Disconnect the Vacuum Pump from the Vacuum Valve carefully 

and then put back Protection Cap to the Vacuum Valve. Do not move or shake the 

housing or put the housing under the sun when the analyzation process has started.

The  Vacuum  Analyzation  Process  takes  approx.4  minutes.  Once  the  process  is 

completed, the Signal Indicator will turn either RED or GREEN, depending on the 

result:

The UH-EPL10 is designed to grow and expand with your needs and skills. Whether 

you attach a wet lens (wide-angle conversion lens or close-up lens) directly onto the 

front  of  the  lens  port  or  the  use  of  dedicated  camera  lenses  (Wide-angle  Lens, 

Fisheye Lens or Macro Lens) on the camera. We have a wide range of compatible 

Olympus camera lenses, AOI Lens Ports and AOI Wet Lenses to meet even the most 

demanding of underwater photographers. 

Below is an example of the possible expansion path for AOI UH-EPL10. 

The ultra-compact Flat Port (

AOI FLP-06-GRY

) comes standard with the housing and it 

can be removed for cleaning, inspection, and lubrication of the lens port O-rings (

AOI 

POR-02

) on it.

While depressing the Port Release Button, rotate the Lens Ports counter-clockwise 

until it stops. Remove the Lens Port by pulling it evenly out from the housing body. If 

the resistance is too great when rotating the Lens Port, the use of an optional tool 

(sold separately) - Port Remover (

AOI PR-01

) may be required.

For more information on other products and accessories, visit 

www.aoi-uw.com

 or 

consult with your local dealer.

Blinking GREEN – 

Vacuum Analyzation passed and Housing is ready to go into  

the water.

Blinking RED – 

Vacuum Analyzation failed and inspection for leak is required. 

-

-

In  case  of  a  significant  air  leakage  detected  anytime  during/after  the  Vacuum 

Analyzation Process, the Signal Indicator will turn Blinking RED. 

Below (Table 2) is the summary of Signal Indicator Color Codes Indication.

1. Perform Vacuum Analyzation

a.

b.

-

-

-

-

(xiii)

AOI UH-EPL10

AOI UH-EPL10-WHT

White

AOI UH-EPL10-GRY

Grey

Olympus PEN E-PL9 or E-PL10 with kit lens 

M.ZUIKO DIGITAL ED 14-42mm F3.5-5.6 EZ

Charging : USB Charger DC 5V, 0.5A (not included)

Approx. 1.5 hours for a fully charge

Battery Operation Time : Approx. 3 days

(based on 3 dives/day and approx. 250 shots/dive)

Approx. 166mm (W) x 128mm (H) x 135.5mm (D)

Model Number

Compatible

Camera Models

Housing Color

45 Meters (148 ft.)

Main Material

Waterproof

Operating

Environment 

Dimensions

Underwater : Approx. 26g

(LCD Monitor Hood, Lanyard, camera, kit lens, batteries,

media card and lens gear included)

On Land : Approx. 734g

(LCD Monitor Hood and Lanyard included,

camera and accessories not included)

Weight

Operation : 0 C ~ 40 C (32 F ~ 104 F)

Storage : -20 C ~ 60 C (-4 F ~ 140 F)

Built-in Rechargeable Lithium Polymer Battery (3.7V)

Battery

AOI is a registered trademark of AOI Ltd. All rights reserved.

www.aoi-uw.com

6E01004D-00001

All other trademarks are the property of their respective owners.

Made in China

Housing Body : Polycarbonate

Flat Port Glass : Optical Glass with double sided

multi-layer AR coating

Summary of Contents for UH-EPL10

Page 1: ... your purchase of an AOI product Please read this general guide prior to using the housing It will provide an overview of how this product can be used for optimal performance For additional information please consult your local dealer or write to info aoi uw com ...

Page 2: ...1 Extended Shutter Release Lever LCD Monitor Hood Spare Main Seal O ring x 1pc Spare Vacuum Valve Protection Cap O ring x 1pc 1 2 3 4 5 6 7 8 9 10 Silica Gel AOI SIGE 3 Silicone Grease AOI SIGR 5 Lanyard Port Front Cap for M67 Thread AOI LFC 01 Port Rear Cap for PEN Mount AOI PRC 02 O ring Remover White Balance Card AOI ORR 01 Lens Cleaning Microfiber Cloth AOI MC 01 AOI Logo Sticker General Guide...

Page 3: ...er Optical Cable Ports Flat Port Glass Cam Lock Cam Lock Release Security Lock LCD Monitor Hood Wet Sensor Strip Camera Positioning Bumper Multi control Device Signal Indicator Micro USB Port Power ON OFF Switch Housing Main Seal O ring Rear Cover 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 6 7 21 8 2 1 5 9 3 4 14 13 11 12 17 18 15 16 16 16 22 9 16 16 16 19 20 10 ...

Page 4: ...mic Thumb Rest Button Button Button Arrow Pad Button Installing the camera in the housing Camera Olympus PEN E PL9 or E PL10 Camera Lens M ZUIKO DIGITAL ED 14 42mm F3 5 5 6 EZ Lens Gear AOI LG OM 1442EZ Before use ensure that the camera and camera lens are compatible with the housing lens port and lens gear Reference to port chart on page 14 a 23 24 25 26 29 30 31 32 33 34 35 36 39 41 40 37 38 33 ...

Page 5: ...ternal external pressure twist the red colored Vacuum Release Tip counter clockwise fig ii b Unlock the Security Lock on the Cam Lock fig iii Press down on the Cam Lock Release and rotate the Cam Lock counter clockwise at the same time fig iv Rotate the Cam Lock until the Rear Cover is fully separated from the Cam Lock c Open In air i ii iii iv v ...

Page 6: ...he battery The table below shows the status of the battery charging and the corresponding light of the Signal Indicator Battery operation time per charge is approx 3 days based on 3 dives day and approx 250 shots dive d e USB DC 5V Signal Indicator Indication Next Action Fast Blinking BLUE light 4 times sec Charge is required Connect it to a USB charger for charging Fast Blinking GREEN light Charg...

Page 7: ...ion and make sure the Camera Strap Eyelets are folded down against the camera body fig vii Load the camera into the housing gently and do not hold the camera by the Monitor Screen while inserting f If using the Optical Flash Trigger for the external Slave Strobes the Hot Shoe Connector must be connected between the camera s hot shoe and to the Micro USB Port on the Multi control Device fig viii an...

Page 8: ...ing Rear Cover by rotating the Cam Lock clockwise until a Click sound is heard fig xi If you encounter resistance clear obstacles before continuing Switch the Security Lock on the Cam Lock to the LOCK position in order to prevent Cam Lock from opening accidentally fig xii Turn on the power of the Multi control Device fig x h i j k l Close Once the camera is installed and housing is closed turn on ...

Page 9: ...nsure camera is off close the Rear Cover according to the steps described in Installing camera into the housing Take off the Protection Cap from the Vacuum Valve and connect the Vacuum Pump onto the Vacuum Valve Tip Pull and Release the Vacuum Pump handle gently and repeatedly for Vacuum Pumping During the Vacuum Pumping process check carefully for changes in color on the Signal Indicator 1 Perfor...

Page 10: ...rnate YELLOW RED Internal vacuum level is above the desired value Stop pumping and carefully release air by gently twisting the Vacuum Release Tip counter clockwise slightly until the Signal Indicator turns to Still YELLOW If too much air is released into the housing the Signal Indicator will change back to Blinking YELLOW again Resume vacuum pumping until Signal Indicator turns to Still YELLOW Th...

Page 11: ...ease ensure that the Vacuum Valve Cap is in place and completely closed When using the housing make sure that it is properly secured to you and accessories are properly secured to the housing Do not exceed the housing maximum depth rating of 45 meters 148 ft If the Wet Detection alarm is triggered during use it means water has entered into the housing If that happens try to position the housing le...

Page 12: ...er optic cable into the Fiber Optic Cable Port of the housing fig xv and then insert the other end into the fiber optic cable port on the external flash or strobe The flash trigger signal electrical signals will be transferred from the camera Hot Shoe to the Multi control Device through the Hot Shoe Connector included in the package The Optical Flash Trigger in the Multi control Device will conver...

Page 13: ...is properly installed and locked xvii xviii xix xx 13 The ultra compact Flat Port AOI FLP 06 GRY comes standard with the housing and it can be removed for cleaning inspection and lubrication of the lens port O rings AOI POR 02 on it While depressing the Port Release Button rotate the Lens Ports counter clockwise until it stops Remove the Lens Port by pulling it evenly out from the housing body If ...

Page 14: ... FLP 06 GRY Antireflective Ring POSR EP02 M ZUIKO DIGITAL ED 60mm F2 8 MACRO M ZUIKO DIGITAL ED 30mm F3 5 MACRO PPZR EP07 OLYMPUS PPZR EP03 OLYMPUS CAMERA LENSES GEARS ANTIREFLECTIVE RINGS PORTS EXTENSION RINGS WET LENSES 14 The UH EPL10 is designed to grow and expand with your needs and skills Whether you attach a wet lens wide angle conversion lens or close up lens directly onto the front of the...

Page 15: ...o clean the O Ring groove Do not use cleaning substances other than fresh water Remove sand dirt hair or fibers that can prevent a proper housing seal To lubricate O rings apply a small amount of silcone grease AOI SIGR 5 on your fingertips gently pull the O ring through the fingertips This will lightly coat the entire O ring with silicone grease Only use the AOI Silicone Grease supplied or those ...

Page 16: ...ial Waterproof Operating Environment Dimensions Underwater Approx 26g LCD Monitor Hood Lanyard camera kit lens batteries media card and lens gear included On Land Approx 734g LCD Monitor Hood and Lanyard included camera and accessories not included Weight Operation 0 C 40 C 32 F 104 F Storage 20 C 60 C 4 F 140 F Built in Rechargeable Lithium Polymer Battery 3 7V Battery AOI is a registered tradema...

Reviews: