Service Manual G2460PQU
20
5.3 Absolute Max Ratings
Absolute maximum ratings of the module are as follows:
Parameter
Symbol
Min
Max
Unit
Conditions
Logic/LCD Drive Voltage
V
DD
0
6.0
[Volt]
Note1,2
LED Current
ILED
-
120
[mA]
Note1,2
Operating Temperature
TOP
0
+50
[
℃
]
Note3
Glass surface temperature(Operation)
TGS
0
+65
[
℃
]
Note3,4
Operation Humidity
HOP
5
90
[%RH]
Note3
Storage Temperature
TST
-20
+60
[
℃
]
Storage Humidity
HST
5
90
[%RH]
Note1: Within Ta (25
℃
).
Note2: Permanent damage to the device may occur if exceeding maximum values.
Note3: Temperature and relative humidity range are shown as the below figure.
1. 90% RH Max (Ta
≤
39
℃
)
2. Max wet-bulb temperature at 39
℃
or less (Ta
≤
39
℃
)
3. No condensation.
Note4: Function Judged only