-BL2LN87SB02D*CC20  1/20-

IN0

IN1

LINK

ALM

IN1

IN0

BL2LN87SB-02D

-CC20

Ver.1.1

ASLINKER 

[Smart ASLINKER]

AnyWireASLINK System Products Guide

BL2LN87SB-02DS-CC20

BL2LN87SB-02D-CC20

[Type]

A WARNING indicates a potentially hazardous 

situation which, if not handled correctly, could 

result in death or serious injury.

[Warranty]

 Warranty period

  The warranty on the delivered Product shall continue to be effective for one (1) 

year after the delivery thereof to a location as designated by the original owner.

 Scope of warranty

  Should a defect occur in any part of the Product during the foregoing warranty 

period when it is used normally in accordance with the specifications described 
in this Products Guide, the Company shall replace or repair the defect free of 
charge, except when it arises as a result of:

  [1] Misuse or abuse of the Product by the owner;
  [2] Fault caused by other than the delivered Product;
  [3] The unauthorized modification or repair of the Product by any person other 

than the Company’s personnel;

  [4] Any unusual force of nature, disaster or other cause beyond the Company’s 

control.

  The term “warranty,” as used herein, refers to the warranty applicable to the 

delivered product alone. The Company shall not be liable for consequential or 
incidental damages resulting from any malfunction.

 Repair at cost

  After the expiration of the warranty period, the owner shall be responsible for all 

costs and expenses incurred for the troubleshooting and repair of the Product. 
Even during the warranty term, the Company shall repair any defects arising 
from causes other than within the scope of the warranty as specified above, at 
the owner’s cost.

 Changes in the product specifications and the descriptions in the manual

  The descriptions in this manual may be subject to change without notice.

Precautions that must be observed in order to use this system safely are indicated as shown below. 

You must observe these precautions.

[Notes on Safety]

A CAUTION indicates a potentially hazardous situation 

which, if not handled correctly, may result in personal 

injury or property damage.

 Note on use 

A separate Address Writer is required to set addresses and other data.

 *

 For more information, refer to [Various Settings] on page 9.

NPN input
PNP input

 

CAUTION

WARNING

  System power supply

  Use a stable, 24V DC power supply. Use of an unstable power supply may cause problems with the system.

  Separately route high-voltage and power cables

 

Although the AnyWireASLINK has a high noise margin, install the transmission line and I/O cables away from high-voltage and power 
cables.

  Connectors and terminals

- Pay careful attention to the length and installation of cable wiring to ensure that connectors and cables are neither overloaded nor disconnected.
- Make sure to prevent any metal objects from getting inside the connectors or the terminal blocks.
- Short-circuits caused by metal objects or mis-wiring are likely to damage the device.

  Do not impose any external loads on the units. Doing so may cause a failure.

  Do not disconnect or reconnect between the transmission line and slave units when the transmission line is active. A malfunction may occur.

  Use the AnyWireASLINK within the range of the specifications and conditions shown below.

  System Safety

  This system is intended for general industrial applications. It does not have functions for supporting applications requiring higher 

levels of safety such as safety-related devices or accident prevention systems. The product must not be used for these purposes.

  Always turn off the power in installing or replacing the system.

  Prolonged continuous flow of a rated load current or higher or a transit current due to load short-circuit, etc., in the hybrid unit including 

the output unit and the output circuit may result in smoking or firing. An external safety device such as a fuse must be installed.

CAUTION

WARNING

[About Pictogram

*

1

]

Ver. 1.0

*

2

Compatible with

Ver. 1.1

*

3

*

1 The pictogram may not be marked (or stuck) depending on the product.

*

2 AnyWireASLINK device not compatible with Ver. 1.1 (word transmission and 

single unit simplified replacement functions)

 

Some products, not marked with the Ver. 1.1 pictogram, are compatible with 
the functions included in Ver. 1.1. Refer to the lot No. and the product guide 
for ultimate confirmation.

*

3 For details of Ver. 1.1, refer to the subsequent pages.

Summary of Contents for ASLINKER BL2LN87SB-02D CC20 Series

Page 1: ...operty damage Note on use A separate Address Writer is required to set addresses and other data For more information refer to Various Settings on page 9 NPN input PNP input CAUTION WARNING System powe...

Page 2: ...t Lot No About Word Transmission 3 Some products have no indication of function version Year Numbers Lower two digits of the Christian era Month Alphabet as per the table below 19E means May 2019 Sing...

Page 3: ...ified replacement function see the lot No and the manual for the slave unit When a slave unit of a new function version is replaced with that of an old function version the single unit simplified repl...

Page 4: ...onditions are satisfied Functions Bit transmission ASLINKER 4 wire isolated cable type General purpose sensors General purpose switches Word 1 2 transmission Single unit simplified replacement 3 Remot...

Page 5: ...a four wire isolated terminal in the case of input and load driving using an external power supply How to Connect AnyWireASLINK AnyWireASLINK terminator One terminator should be connected to the DP DN...

Page 6: ...r lines start running in parallel This will improve noise resistance suppress the adverse effects of crosstalk caused by transmitted signals and stabilize signals The above filters must be inserted re...

Page 7: ...total length of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m 24V DC stabilized power supply General purpose power supply filter Use it if necessary 2 wire termina...

Page 8: ...tings are enabled or not Operation during restoration Power supply line disconnection error will be automatically reset by eliminating the cause of disconnection Signal line disconnection error will b...

Page 9: ...reen Input indicator Orange Input indicator Orange Alarm indicator Red Name of Each Part Input line connection wires Pin No Wire color Applicable LP connector LP4 WW 10P Example of fitting the LP conn...

Page 10: ...ction may be caused depending on the sensor to be connected If that happens change the setting as follows Example 1 Signal line disconnection occurs all the time Set to Monitoring enabled for power su...

Page 11: ...n 3 subsequent to corresponding input signal address setting Example When this unit is set to address 4 Variable Address Description CH0 input CH1 input Bit input information area of master unit CH1...

Page 12: ...voltage drop When ALM bit is normal ON mode When this unit is disconnected from the trunk line of the AnyWireASLINK system at occurrence of DP DN disconnection input signals and ALM bits are all turne...

Page 13: ...ng equipment parameter 12 is manual restoration After execution of the short circuit notification cancel command set this parameter to OFF Otherwise operation of the short circuit notification cancel...

Page 14: ...ion Bit input information area Number of bit input points 2 n 1 Number of bit input points 2 n Example When the number of bit transmission points for the master unit is input 64 points output 64 point...

Page 15: ...rmally connected and the unit is set to the factory set address For S W version A or 3 digit lot No This condition is detected when the master unit executes automatic address recognition LINK Green AL...

Page 16: ...djust the power supply voltage of an external power source connected to the slave unit I O line so that the power supply voltage does not exceed the rated voltage range 21 6V to 27 6V Make sure that w...

Page 17: ...t ON voltage OFF voltage Allowable current at 24VL 24V DC 3 5mA 2 2mA or more 1mA or less 16V or more 24VL IN 8V or less 24VL IN 50mA max 24VL 0VL per point Internal circuit 4 wire isolated NPN input...

Page 18: ...ear short circuit status after short circuit is detected Notification by differentiating disconnected CH When ALM bit is normal OFF Notification by differentiating disconnected CH When ALM bit is norm...

Page 19: ...ransmission line disconnection transmission line short circuit transmission power supply drop and duplicated unregistered ID Transmission specifications 1 Do not use or store AnyWireASLINK devices in...

Page 20: ...8 2019 2020 UMA 16324AK EN BL2LN87SB02D CC20 20 20 Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by website http ww...

Reviews: