In a power supply system from a certain power source, if the total length of DP, DN, 24V and 0V lines in parallel connection exceeds 50m, the 
ASLINK filter ANF-01 should be connected in series to the 24V and 0V terminals at a position where the parallel connection starts.  
This filter should be inserted in both cases: batch power supply from a power source for the master unit, and power supply from a local power 
source.

[How to Use the Filter]

Connection example

To ensure conformity to the CE standard, insert the ANF-01 filter regardless of the distance of lines 
in parallel connection.

Terminator

Terminator

General-purpose power

supply filter

(Use it if necessary.)

 

24V DC stabilized 

power supply

If the total length of the section where all the DP, DN, 24V, and 0V lines run in parallel is more than 50m

AnyWireASLINK master

AnyWireASLINK master

General-purpose power 
supply filter
(Use it if necessary.) 

24V DC stabilized 
power supply 

Local power supply/branching

If the total length of the 

section where all the 

DP, DN, 24V, and 0V 

lines run in parallel is 

more than 50m

24V DC 
stabilized 
power supply

General-purpose power
supply filter
(Use it if necessary.)

2-wire 

terminal 

2-wire 

terminal 

4-wire 

terminal 

4-wire 

terminal 

4-wire 

terminal 

4-wire 

terminal 

4-wire 

terminal 

4-wire 

terminal 

If the total length of the sections (A + B) 

where all the DP, DN, 24V, and 0V lines 

run in parallel is more than 50m

Power supply to the entire system

2-wire 

terminal 

4-wire 

terminal 

4-wire 

terminal 