© 2020 Anywhere Cart | 42035 Zevo Drive, Temecula CA 92590, USA | 888-650-4488 | www.AnywhereCart.com
© 2020 Anywhere Cart | 42035 Zevo Drive, Temecula CA 92590, USA | 888-650-4488 | www.AnywhereCart.com
USER GUIDE
INTELLI-SENSE SMART CHARGER
Within 5 seconds of plugging in your cart’s power cord, your
INTELLI-SENSE Smart Charging System will initiate an test of
your devices charging level requirements.
Devices which are plugged into power strips that draw the
most power will take priority and can take up to 2 hours before
switching to the next set of outlets. Once devices are fully
charged, the system will remain in a trickle charging state,
maintaining your devices battery levels.
Power Input
Internal Power Button
THE ELECTRICAL SYSTEM IS DESIGNED TO HANDLE A MAXIMUM OF 14 AMPS.
NOTE:
If wattage exceeds 14 Amps or about 1400 Watts at one time, the charging system may
not operate correctly. Review your device’s AC Adapter wattage, multiplying it by 16.
45 Watts
X
16 Devices
720 Watts
95 Watts
X
16 Devices
1520 Watts
75 Watts
X
16 Devices
1200 Watts
With Mode Selection Switch set to
SMART
:
Group Outlets “A” and Group Outlets “B” power on for
8 seconds in sequence then enter the following modes
depending on current draw.
If the total current draw is greater than 9A:
The group outlets with the highest current draw will
power on, while the group with less current draw remains
OFF. Once the current draw difference is within 0.5A, the
system will switch to the other group. When the total
current is less than 9A, all outlets will power on at the
same time.
If the total current draw is less than 9A:
Group “A” and Group “B” power on at the same time.
The total output is continuously monitored in case a new
device is added.
Group Outlets “A” Group Outlets “B”
7 Amp load
5.5 Amp load
ON
OFF
5 Amp load
5.5 Amp load
OFF
ON
5 Amp load
4.5 Amp load
ON
OFF
4.5 Amp load
4.5 Amp load
ON
ON
The AC-PLUS-T, AC-SLIM, AC-MAX, AC-45, AC-PRO-II and AC-MANAGE are
equipped with the INTELLI-SENSE Smart Charging System. This system will initiate an
test of your devices charging level requirements. Devices which are plugged into power
strips that draw the most power will take priority. Once devices are fully charged, the
system will remain in a trickle charging state, maintaining your devices battery levels.
1. Power Cord Inlet
2. Internal Power Button
3. Mode Selection Switch
1
2
3
4
5
6
7
8
How It Works
888.650.4488
www.AnywhereCart.com
S
ubject to change without notice
42035 Zevo Drive,
Temecula, CA 92590
Intelli-Sense System Overview
1. Plug in device adapters so there are an
equal number of devices in Group A
and Group B.
2. Make sure the Mode Selection Switch is
set to “SMART” mode.
3. Plug in cart.
The Intelli-Sense timer will automatically
sense the charging needs of the cart and
start charging in the most effcient and
quickest method.
Quick Start Guide
With the Mode Selection Switch set to
SMART:
Group Outlets “A” and Group Outlets “B” power on for 8 seconds in sequence then enter the
following modes depending on current draw.
If the total current draw is greater than 9A:
The group outlets with the highest current draw will power on, while the group with less
current draw remains OFF. Once the current draw difference is within 0.5A, the system
will switch to the other group. When the total current is less than 9A, all outlets will
power on at the same time.
If the total current draw is less than 9A:
Group “A” and Group “B” power on at the same time.
The total output is continuously monitored in case a new device is added.
4. External Switch Cable
5. LED Indicators
6. Auxiliary Outlets
(Always ON)
7. Group Outlets “A”
8. Group Outlets “B”
À
À
À
For units shipped June 1, 2018 forward
Group Outlets “A” Group Outlets “B”
7 Amp load
5.5 Amp load
ON
OFF
5 Amp load
5.5 Amp load
OFF
ON
5 Amp load
4.5 Amp load
ON
OFF
4.5 Amp load
4.5 Amp load
ON
ON
The AC-PLUS-T, AC-SLIM, AC-MAX, AC-45, AC-PRO-II and AC-MANAGE are
equipped with the INTELLI-SENSE Smart Charging System. This system will initiate an
test of your devices charging level requirements. Devices which are plugged into power
strips that draw the most power will take priority. Once devices are fully charged, the
system will remain in a trickle charging state, maintaining your devices battery levels.
1. Power Cord Inlet
2. Internal Power Button
3. Mode Selection Switch
1
2
3
4
5
6
7
8
How It Works
888.650.4488
www.AnywhereCart.com
S
ubject to change without notice
42035 Zevo Drive,
Temecula, CA 92590
Intelli-Sense System Overview
1. Plug in device adapters so there are an
equal number of devices in Group A
and Group B.
2. Make sure the Mode Selection Switch is
set to “SMART” mode.
3. Plug in cart.
The Intelli-Sense timer will automatically
sense the charging needs of the cart and
start charging in the most effcient and
quickest method.
Quick Start Guide
With the Mode Selection Switch set to
SMART:
Group Outlets “A” and Group Outlets “B” power on for 8 seconds in sequence then enter the
following modes depending on current draw.
If the total current draw is greater than 9A:
The group outlets with the highest current draw will power on, while the group with less
current draw remains OFF. Once the current draw difference is within 0.5A, the system
will switch to the other group. When the total current is less than 9A, all outlets will
power on at the same time.
If the total current draw is less than 9A:
Group “A” and Group “B” power on at the same time.
The total output is continuously monitored in case a new device is added.
4. External Switch Cable
5. LED Indicators
6. Auxiliary Outlets
(Always ON)
7. Group Outlets “A”
8. Group Outlets “B”
À
À
À
For units shipped June 1, 2018 forward
Mode Selection Switch
External Cable Port
Cycle Outlets “A”
Cycle Outlets “B”
Auxiliary Outlets
(Always ON)
QUICK START TIPS