5

 

Initial Turn On   

Please locate and have handy for reference a copy of your 

140W TX Factory Test 

Report

 as well as the 

140W TX Quick Start Guide

, and 

140W PA and Exciter 

User Manuals.

 

 

1.

 

With all equipment turned OFF, please make the cable connections according 
to  the  System  Interconnect  Diagram  of  section  4.  Make  sure  the  BPF  or  PA 
output  is  properly  connected  to  your  Antenna  feed  or  a  suitable  station  load 
before proceeding further. 

2.

 

Turn ON the Exciter via its rear panel AC switch. 

3.

 

Check  Exciter  settings.  Check  the  operating  Frequency  of  the  Exciter  by 
navigating to the Exciter FREQ submenu (simultaneously press Left and Right 
buttons) 

 
 
 
 
 
 
 
 

Check the Exciter drive level is set to -25dBm by navigating to the Exciter 
RF submenu (from above, press ESC button then enter the RF submenu). 

 
 
 
 
 
 
 

(Please refer to  your Exciter User Manual for help with  detailed operation of 
the Exciter).   
 

4.

 

Turn the 140W PA ON via the PA rear panel breaker, then press the front panel 
PA RF On/Off button to turn ON the PA - which should turn BLUE when ON. 
 

5.

 

The built-in FWD and REF power metering in your 140W TX has already been 
calibrated  at  the  factory.  The  Exciter  PAC  submenu  contains  the  System 
Forward and Reflected power meter  readings PA_Fwd and PA_Ref.  Visit  the 
PAC menu on the Exciter  LCD (under Advanced submenu) or Web interface 

Summary of Contents for ATSC 140W

Page 1: ...ANYWAVE ATSC 140W DTV Transmitter Quick Start Guide Version 1 3 September 29 2014...

Page 2: ...ssumed for its use The manufacturer makes no representations or warranties either expressed or implied by or with respect to anything in this manual and shall not be liable for any implied warranties...

Page 3: ...are required from Anywave for all equipment returns Please direct all return inquiries to the Anywave Service Department at support_us anywavecom com providing the Sales Order number and Serial Number...

Page 4: ...ided as a general guide for trained and qualified personnel well aware of the dangers inherent in handling potentially hazardous electrical transmission equipment The installation operation maintenanc...

Page 5: ...ATSC 140W TX Quick Start Guide ACT 140 QSG DOC V1 3 09 29 2014 Page 5 of 13 Contents 1 Introduction 6 2 Organization of Manual 6 3 TX System Overview 7 4 TX System Interconnect 8 5 Initial Turn On 9...

Page 6: ...d personnel are required to install maintain and service this transmission equipment 2 Organization of Manual This Manual is broken up into several sections Section 3 TX system Overview Provides a gen...

Page 7: ...e The TX then goes through a final 24 hour burn in period and check out before being shut done and packed up for shipment In your shipment you should receive a copy of the following documentation Pack...

Page 8: ...r PA FWD and REF samples and a BPF optional with two additional single port couplers for Exciter feedback samples optional The diagram below shows the overall system interconnect between the system co...

Page 9: ...ck the operating Frequency of the Exciter by navigating to the Exciter FREQ submenu simultaneously press Left and Right buttons Check the Exciter drive level is set to 25dBm by navigating to the Excit...

Page 10: ...itoring the PA_Fwd system power meter on the Controller HOME screen as shown below 7 Continue to slowly raise the FWD power until you reach the full 140W or your desired TPO Be careful to make small i...

Page 11: ...en the signal level is out of range too high or too low Add or remove the appropriate attenuator padding to achieve feedback signal levels in the desired range Note the AFTER filter feedback sample is...

Page 12: ...Left and Right buttons and change the value of IP please reference your Exciter User Manual for details 16 If using the Exciter Built in remote web interface for remote control please be sure to set t...

Page 13: ...CT 140 QSG DOC V1 3 09 29 2014 Page 13 of 13 Anywave Communication Technologies Inc 300 Knightsbridge Parkway Suite 150 Lincolnshire IL 60069 Tel 847 415 2258 Fax 847 415 2112 Email sales_us anywaveco...

Reviews: