ACT-5X Exciter User Manual 

Version 3.0 05/07/2015 

 

Page 24 of 26 

 

 

 

 

Equalization error 

 

Alarm message 

 

LCD: 

 

 

None 

 

LED_ TS2: 

 

Off 

 

LED_ TSErr:   

Flashing 

 

Dry Loop: 

 

0 V (SysErr Fault) 

 

Cause:  If  LED_  TS1  is  also  off,  it  means  the  input  RF  signal  could  not  pass  the  prior 

synchronization  step  so  the  equalization  step  is  not  started  yet.  If  LED_TS1  is  on  but  still 

LED_TS2 is off, then it means the input signal has poor signal quality so that it could not pass 

the equalization and therefore could not be demodulated successfully. 

 

Solution:  If  the  synchronization  is  OK  (LED_TS1  remains  ON),  adjust  the  Rx  antenna  for  a 

better reception. If the problem still exists, restart the translator. 

5.3 GPS 

 

No GPS 

 

Alarm message 

 

LCD: 

 

GPS NoGPS 

 

LED_ GPS: 

Off 

 

Cause: This warning displays when no external GPS is connected.   

 

Solution: Check the connection with external GPS device.   

 

GPS Unlocked 

 

Alarm message 

 

LCD: 

 

GPS UNLOCK 

 

LED_ GPS: 

Off 

 

Cause: The selected reference clock is unlocked or unstable. 

 

Solution: Check the status of external GPS device. 

5.4 ADPC 

 

Feedback Signal Level 

 

Alarm message 

 

LCD:   

 

"FEEDBACK TOO BIG! Press Any key to Esc"   

 

 

 

 

Or "FEEDBACK TOO SMALL! Press Any key to Esc" 

 

LED_ SysErr: Flashing (during the ADPC process) 

 

Dry Loop: 

0 V (SysErr Fault) 

 

Cause:  Feedback  signal  level  is  too  high  or  too  low  from  the  very  beginning  of  each  part  of 

ADPC function. 

 

Solution:  Cancel  the  ADPC  function  manually  and  then  adjust  the  input  level  of  the  feedback 

signal according to the messages on the LCD. Start the ADPC function again after the problem is 

resolved. 

Summary of Contents for ACT-5X

Page 1: ...ANYWAVE ACT 5X ATSC Exciter Translator User Manual Version 3 0 ACT 5XU A C May 7 2015...

Page 2: ...means without the express written permission of Anywave Communication Technologies Inc Disclaimer Information provided by Anywave Communication Technologies is believed to be accurate and complete ho...

Page 3: ...eration Specifications 6 3 Menu 8 3 1 Initialization 8 3 2 Query Mode 8 3 3 User Menu 10 3 4 Advanced Menu 15 3 4 Web Interface 19 4 Connection 21 4 1 Connect the Transmitter 21 4 2 Start ADPC functio...

Page 4: ...mode LED_ TS1 Green light on indicates the synchronization of input RF signal is OK LED_TS2 Green light on indicates the equalization of input RF signal is OK LED_TSErr Red light on indicates there i...

Page 5: ...n RF signal output N type female nominal 0 dBm output DRYLOOP RS232 Dry loop for remote control REMOTE RS232 Serial port for remote control REMOTE RJ45 B 10M 100M Ethernet for remote control TSoIP RJ4...

Page 6: ...or BNC female Impedance 50 Level 30 dBm 0 dBm Recommended range 15 dBm 5 dBm Location Back Panel AGC_IN Connector BNC female Impedance 50 DC Voltage 0 V 5 V Location Back Panel RF_OUT Connector N type...

Page 7: ...fications No Content Unit Value 1 Input Level mv 200 2 Positive Transition 20 80 ps 1200 3 Negative Transition 20 80 ps 1200 4 Deterministic Jitter 10 5 Random Jitter 8 Note 1 The electrical interface...

Page 8: ...TS_IN_2 and performs a modulation at the specified transmit frequency The first step after turning on the unit is to confirm the desired operating mode Exciter or Translator according to your applicat...

Page 9: ...R and about 3 seconds to get the first reading of LID and UID After averaging the displayed upper limit on the TSNR is about 39 dB and about 54 DB for the IMD metrics 2 The RSNR and RSSI in Table 3 ar...

Page 10: ...cursor to the target parameter and then press the Up or Down buttons to select different options from the drop down boxes Once you have selected the desired option press the OK button to apply and sa...

Page 11: ...mputing coefficients for both the linear and non linear pre correction for the entire transmission system including the distortion of both transmitter and band pass filter This process takes about 8 t...

Page 12: ...translator system level automatic gain control AGC has options ON and OFF LVL and REF are decimal numbers whose range is from 0 to 255 LVL is the reading of the DC voltage from Port AGC_IN which refle...

Page 13: ...the FREQ sub menu specifies the channel frequency for the modulated RF output signal of the exciter translator 3 The Hz parameter provides a direct adjustment offset of the frequency of the TXFREQ RF...

Page 14: ...hich is setup in CONFIG sub menu in a browser s address bar the login interface will pop up and give user prompts to input the user name and password There are two tiers of web interface available The...

Page 15: ...IG Then press both the Up and Down buttons at the same to enter Advanced Menu as shown below Table 12 Advanced User Menu Welcome to advanced interface AD1 MUTE TX_EX DPD LATCH SN PAC Table 13 through...

Page 16: ...alf Full the system will NOT DELETE any new coming packets c Bit0 The switch of Program Clock Reference Correction function 1 means PCR function is ON 0 means PCR function is OFF 2 Sw_Up and Sw_Down a...

Page 17: ...es from 0x0 to 0xF The lower the parameter s value is the harder the reduction of crest factor will be And 0xF means bypass the whole CFR function No reduction at all Note If ADPC Pre correction is on...

Page 18: ...eading will keep flashing indicating the feedback level may need to be adjusted Table 17 Latch Menu RESET U1 U2 RF GPS TS SYS 1PPS SFN Default OK 0 0 0 0 0 0 0 0 Options OK 0 0 0 0 0 0 0 0 CLR 1 1 1 1...

Page 19: ...e exciter translator IPaddress 192 168 1 143 will bring up the following login window There are two tiers of web interface available The first guest tier is limited in monitoring and control allowing...

Page 20: ...ACT 5X Exciter User Manual Version 3 0 05 07 2015 Page 20 of 26 admin web interface...

Page 21: ...exciter translator s feedback level 30 dBm 0 dBm and recommended range is 15 dBm to 5 dBm 1 If the signal level is out of range use extra devices e g attenuator to make adjustments 2 If the signal le...

Page 22: ...e pre correction data immediately and leave the corresponding status on the front panel LCD Press any key to cancel the ADPC function manually and restart the ADPC function again after the problems ar...

Page 23: ...the bit rate required Solution Adjust the TS input bit rate Or connect all devices with the same reference clock GPS Note When in Exciter Mode it has bit rate auto adaptation function to deal with the...

Page 24: ...translator 5 3 GPS No GPS Alarm message LCD GPS NoGPS LED_ GPS Off Cause This warning displays when no external GPS is connected Solution Check the connection with external GPS device GPS Unlocked Ala...

Page 25: ...IMD or SNR during ADPC process does not pass the pre set threshold Solution Cancel the ADPC function manually and then check the status of connection and entire transmitting system Start the ADPC fun...

Page 26: ...d reception The LED lights on the front panel could provide some indications in these situations Or check the setting of RF via front panel serial port or WEB interface and ensure it s turned ON Resta...

Reviews: