8.  External Scene Control 

 
8.1.  Pre-July 2018 Models 
 
The Anyscene 512 also has the ability to use external isolated closing contacts to cycle 
round memories 1-7 in ascending sequence.  The contacts should be connected to the 
two screw terminals on the back of the Anyscene 512 PCB, and the EXT DIL switch should 
be set to ON.   
 
When the Anyscene 512 is in DMX output mode (and not when in auto cycle mode), the 
next scene from the 1-7 scene cycle will be selected on each contact closure.  To facilitate 
‘debouncing’ of contact closure, contact closing inputs which occur less than two seconds 
after the previous contact closure will be ignored. 
 
As with the auto cycle mode, if the power is disconnected during this step cycling, when 
the power is restored the cycle will be restarted from whichever scene was first in the cycle.  
 
Whilst in step cycle mode, whichever scene is active, it can be overridden by pressing one 
of the scene recall buttons.  The next contact closure will cause the Anyscene 512 to step 
on  to  the  next  scene  after  this  manually  recalled  scene.    The  remote  contacts  can  be 
disabled by switching the EXT DIL switch to OFF. 
 
When in auto cycle or standby/receive modes, all contact closures are ignored. 
 
 

 

 

Summary of Contents for Anyscene 512

Page 1: ...he system rests with the installer and these notes are intended only for guidance Contents 1 Overview and Operation 2 2 Mounting 2 3 Power Supply Connection 3 4 DMX Requirements 4 4 1 DMX Loading 4 4...

Page 2: ...t is powered up and the yellow data LED indicates that the unit is receiving suitable programming data from a DMX source Switch 0 is the blackout switch and when enabled the corresponding red LED will...

Page 3: ...o 50 mA When using multiple Anyscene 512 they should be linked together in series with each other and then linked to the receiving equipment Anytronics dimmers or the AS180 If used with other Anytroni...

Page 4: ...ced in any order along the DMX line but the equipment at either end of this DMX line whether receiving equipment or an Anyscene 512 should have a termination resistor fitted for best results 4 3 Line...

Page 5: ...512 units into a standby receive state To ensure that the scene memory contents remain intact in such multiple unit installations it is vital that once scene programming has been completed the MWP swi...

Page 6: ...on 1 RFP No Function 2 MWP ON Internal memory protected Normal Operation OFF Internal memory not protected Programming Mode 3 256 No Function 4 Master Speed See Section 6 2 5 Fade x2 See Section 6 3 6...

Page 7: ...DIL No Name Function 1 MEM ON Internal memory protected Normal Operation OFF Internal memory not protected Programming Mode 2 Master Speed See Section 6 2 3 Fade x2 See Section 6 3 4 Fade x4 See Sect...

Page 8: ...alter the duration and speed of the cycling As supplied with DIL switch 4 set to OFF the default time spent in each scene is approximately 10 seconds Master Speed DIL OFF The Up and Down buttons can b...

Page 9: ...as follows Fade x 2 Fade x 4 Fade Time Seconds OFF OFF 2 5 OFF ON 5 ON OFF 10 ON ON 20 6 4 Clearing All Memories To clear all saved scenes within the Anylight 512 the following procedure should be fo...

Page 10: ...flash twice to show the data has been saved h Repeat e to g for all required scenes i Once all scenes have bee saved turn the MWP DILL ON to protect the recently programmed scenes Note To access scene...

Page 11: ...cene from the 1 7 scene cycle will be selected on each contact closure To facilitate debouncing of contact closure contact closing inputs which occur less than two seconds after the previous contact c...

Page 12: ...rating Instructions 8 2 Post July 2018 Models The post 2018 models have the ability to recall individual scenes using external zero voltage contacts and the bank of screw terminals provided on the rea...

Page 13: ...put to DMX addresses 1 512 o Low voltage closing contact input for external scene recall Controls o 8 scene selection buttons o Master level up and down buttons o External scene recall via low voltage...

Reviews: