Thank you for choosing  Anyload EB300 Precision Balance Scale. The EB300 
series precision balance incorporates a fast and stable display with a variety of 
functions such as auto shut-off, auto calibration, auto zero tracking, counting 
functions with memory for 50 items, 20 digital tare memories and 4 units of 
measurement. The EB300 is equipped with a weight checking function with 
visual and acoustic annunciators as well as an advanced gravity compensation 
system for high accuracy weighing. Incorporated into the design of this digital 
scale are adjustable feet to ensure accurate weighing and an RS-232 
communication port for easy data transfer to a PC or printer. 
 
This manual contains operation and maintenance instructions for the 
scale. Please read this manual completely before installation and 
operation 
 

2.

 

Safety Recommendations and Warnings 

 

2.1 Safety Recommendations 

 

When using this weighing equipment the following  
recommendations shall be observed for safety: 

 

The weighing machine may only be used with the power adapter 
supplied exclusively for use with the weighing machine. 

 

Before inserting the power adapter, the user must ensure that 
the operating voltage stated on the power adapter agrees with 
the mains voltage. 

 

If not, please contact Customer Service at the address above. 

 

If the power adapter or its cable is damaged, the 
weighing machine must immediately be disconnected 
from the electricity supply (pull out the power adapter). 

 

The weighing machine may only be operated from mains electricity 
supply with a power adapter which is in perfect condition. 

 

If there should be any reason to believe that it is no longer possible 
to operate the weighing machine without danger, the weighing  
 

Summary of Contents for EB300

Page 1: ...Anyload Transducer Co Ltd Website www anyload com Email info anyload com Fax 1 866 612 9088 North America Toll Free 1 855 ANYLOAD 269 5623 EB300 V1611 Precision Balance Operations Manual V1611...

Page 2: ...ections 6 8 Basic Functions Operation 6 8 1 Zero Adjust 6 8 2 Tare Function 7 8 3 Auto Tare 8 8 4 Current Weighing 9 8 5 Accumulate Weighing 10 8 6 Piece Counting Function 10 8 7 Piece Counting Preset...

Page 3: ...instructions for the scale Please read this manual completely before installation and operation 2 Safety Recommendations and Warnings 2 1 Safety Recommendations When using this weighing equipment the...

Page 4: ...after it has first been re checked by a service technician 2 2 Safety Warnings Please turn off the power before installing or disassembling This is a precision instrument and it should be handled car...

Page 5: ...memory Calibration with gravity adjustment Check weighing mode HI LO OK and status indication Auto power off Built in rechargeable battery and AC adaptor ABS scale enclosure Equipped with adjustable f...

Page 6: ...utton UNIT key Press to change unit In menu mode press to escape from menu and return to normal GROSS NET key When using tare mode press to show the gross weight press again and it will show the net w...

Page 7: ...isplay In menu mode it will show the next function UP key In menu mode it increases the value number on display DOWN key Press to erase accumulated weight memory In menu mode it decreases the value nu...

Page 8: ...e of the container Advice If there are instability or temperature differences display will not show 0 value In this case press key to correct it Tare Range Tare value cannot exceed the maximum scale c...

Page 9: ...place the object on the plate and the tare value will be deducted from weighing value shows net weight Then put the actual object together with the container on the platform and the display will deduc...

Page 10: ...and display will show 0 and tare symbol will be on 2 Place the object or objects inside the recipient or box Display will show net weight deducting the tare recipient box weight 3 Remove all objects...

Page 11: ...ress key to remember the weight of object 2 then LCD will show Add002 Remove object 2 and the value of the weight turns to 0 again To know accumulated weight value press and display will show total ac...

Page 12: ...nd press key to confirm Move the samples away and the LCD display turns to 0 2 Counting Put the total objects no more than the max capacity of the scale on the platform and then you can find the count...

Page 13: ...ge to another pre set value press and hold Scale will show CLU XX where XX is the memory position Use and to change the flashing digit use and to move the digit to the right or the left Press to set t...

Page 14: ...ammed for limit function Scale indicates by a BEEP if weight is in or out the set limits It can be programmed in two different ways 1 Beeps when the weight is within the limitation 2 Beeps when the we...

Page 15: ...is enabled or disabled 0 Weighing without target weight alarm function 1 Weighing with target weight alarm function 2 Select the right target weight you have preset before and press to confirm 3 Conf...

Page 16: ...is stable for about 5 seconds Press to confirm and press to save and escape the preset 9 2 Hold Mode Setting To access function menu press and display will show PLUPro Press until display shows Hold P...

Page 17: ...peration To change it press or 9 4 Stability Filter In adverse environmental conditions or when scale is being used in unstable weighing environments you can increase the weighing stability with filte...

Page 18: ...onverter to verify the proper function of the entire scale including load cells It is useful for our technician to check and identify eventual scale failures Press then press until it shows i count Pr...

Page 19: ...irm by pressing Afterwards display will read PAri 0 which is also an option which cannot be modified and means parity Confirm by pressing and escape by pressing 9 8 Print Format Printer data output ca...

Page 20: ...w LFn follow with two digits Its function is to select the number of empty lines you desire to print after data blocks If you set the value to 1 or 0 the printer will not let empty space between data...

Page 21: ...D displays Si CAL press the LCD displays Si 01 don t touch the platform in the procedure press the LCD displays 000000 place the weights on the platform manually change the 000000 to the real value an...

Page 22: ...21 ANYLOAD EB300 Precision Balance Operations Manual V1611...

Reviews: