58 (104)
10.5
Network Configuration Object (04h)
Category
Extended
Object Description
This object holds network specific configuration parameters that may be set by the end user. A reset com-
mand (factory default) issued towards this object will result in all instances being set to their default values.
If the settings in this object do not match the configuration used, the Module Status LED will flash red to indi-
cate a minor error.
The object is described in further detail in the Anybus CompactCom 40 Software Design Guide.
See also...
•
•
Supported Commands
Object:
Get_Attribute
Reset
Instance:
Get_Attribute
Set_Attribute
Get_Enum_String
Object Attributes (Instance #0)
#
Name
Access
Data Type
Value
1
Name
Get
Array of
CHAR
“Network Configuration”
2
Revision
Get
UINT8
01h
3
Number of instances
Get
UINT16
000Fh (15)
4
Highest instance
number
Get
UINT16
0011h (17)
Instance Attributes (Instance #3, IP Address)
Value is used after module reset.
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“IP address”
(Multilingual, see page
)
2
Data type
Get
UINT8
04h (= UINT8)
3
Number of elements
Get
UINT8
04h (four elements)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
Array of
UINT8
Any change is valid after reset.
Valid range: 0.0.0.0 - 255.255.255.255 (Default =0.0.0.0)
6
Configured Value
Get
Array of
UINT8
Holds the configured value, which will be written to attribute #5
after the module has been reset.
Valid range: 0.0.0.0 - 255.255.255.255 (Default =0.0.0.0)
Anybus
®
CompactCom
™
40 Common Ethernet Design Guide
HMSI-27–269 2.1