background image

Regular Installation

For Midi EM-locks (Model AXM-800M), maximum thickness of door is 48 mm.

Recommendation :

For Maxi EM-locks (Model AXM-1200M), maximum thickness of door is 46 mm.

LZ or Z bracket for inswing doors

1. Pass the power cable through the 

    mounting plate and  Opening Type 

    wiring slot of the magnetic lock.

2. Combine the arc of the mounting 

    plate with the arc of the magnetic 

    lock. 

3.Embed the maglocks into the mounting 

   plate. Fit the magnetic lock from the 

   bottom to the mounting plate.

4.Use the Allen wrench and fixing

   screws to tighten the mounting

   plate and magnetic lock.  

Fold the mounting template 90°.

Drill the holes according to the
marks.

The rubber washer makes the
surface of the armature plate
adjustable in order to completely
fit the surface of magnetic lock.

Fix the mounting plate on the
door with mounting screws.

Connect the power and test the
unit.

Place the template to the proper
position of the door and frame.
Mark the hole positions of the
template on the door and frame.

Please install the armature plate
as illustrated here. (Dimensions
of the holes depend on the door
types illustrated below.)

Fasten the mounting plate with
the mounting screws. The position
of the mounting plate should be
adjustable.

Use the Allen wrench and fixing
bolts to tighten the electromagnetic
lock to mounting plate.

Drill a Ø8mm hole through
door, on closing side. Enlarge
to Ø12.7mm by a sexnut bolt
on the opening side.

Drill a Ø6.8mm hole 
and tap on closing side 
a M8x1.25 thread.

Drill a Ø8mm hole through
door on closing side. Enlarge
to Ø12.7mm by a sexnut bolt
on the opening side.
The depth is 36mm.

Find a mounting position on the door 

frame for the L bracket. Make sure that 

the door can still be closed.

Use the fixing bolts to tighten the

magnet on L bracket.

Assemble the Z bracket and make

sure that the Z bracket is adjustable.

Insert the guide pins into the

armature plate.

Copyright       All rights reserved. P-MU-AM-AXM  Published on: 2021.01.29

Summary of Contents for AXM-800M Series

Page 1: ... DS DBL M DBL M DS DBL M TD DBL M TD DS Holding Force Lock Surface Temperature Humidity Finish The products shall not impair the intended operation of an emergency exit or panic hardware mounted on the door 12 24VDC 500mA 12VDC 270mA 24VDC 32 to 120 2 F 0 to 49 C 800lbs AXM 800M Series AXM 1200M Series 1200lbs Current temperature 20 C 0 to 85 Non condensing Magnet Surface Galvanized Housing Brushe...

Page 2: ...agnet is fitted with a metal oxide varistor to prevent back EMF Make sure the contact area of the electromagnetic lock and the armature plate are clean Wipe the surface of magnetic lock with anti rust oil regularly Brackets installation are according to door swing direction and door frame type e g narrow frame door frameless glass door inswing door etc Regular Installation outswing door L bracket ...

Page 3: ... the template to the proper position of the door and frame Mark the hole positions of the template on the door and frame Please install the armature plate as illustrated here Dimensions of the holes depend on the door types illustrated below Fasten the mounting plate with the mounting screws The position of the mounting plate should be adjustable Use the Allen wrench and fixing bolts to tighten th...

Page 4: ... mode works after the door is closed properly and it can be adjusted from 1 to 80 seconds Models AXM 800MTD AXM 800MDS TD AXM D800MTD AXM D800MDS TD AXM 1200MTD AXM 1200MDS TD AXM D1200MTD AXM D1200MDS TD NO NO COM COM NC NC 1 2 NO NO NO NO Bond Sensor Output Bond Sensor Output Indicates the Bond and functioning status N C contact output Open Not bonding status N O contact output Locked Bonded sta...