Safety Tips

Position on a flat, stable surface.

A service agent/qualified technician should carry out installation and any 
repairs if required. Do not remove any components or service panels on 
this product.

Consult Local and National Standards to comply with the following:

• Health and Safety at Work Legislation
• BS EN Codes of Practice
• Fire Precautions 
• IEE Wiring Regulations
• Building Regulations

DO NOT use jet/pressure washers to clean the appliance.

DO NOT use the appliance outside.

DO NOT use this appliance to store medical supplies.

Always carry, store and handle the appliance in a vertical position and 
move by holding the base of the appliance.

Always switch off and disconnect the power supply to the unit before 
cleaning.

Keep all packaging away from children. Dispose of the packaging in 
accordance with the regulations of local authorities.

If the power cord is damaged, it must be replaced by a RWA agent or 
a recommended qualified technician in order to avoid a hazard.

Product Description

VRX1200/330- 5 x ¼ Container Refrigerated Counter Top/Servery Prep 
VRX1500/330- 7 x ¼ Container Refrigerated Counter Top/Servery Prep 
VRX1800/330- 9 x ¼ Container Refrigerated Counter Top/Servery Prep 
VRX2000/330- 10 x ¼ Container Refrigerated Counter Top/Servery Prep 

Introduction

Please take a few moments to carefully read through this manual. Correct 
maintenance and operation of this machine will provide the best possible 
performance from your RWA product.

Pack Contents

The following is included:

RWA prides itself on quality and serv ice, ensuring that at the time of 

packaging the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your RWA

dealer immediately.

Installation

1. Remove the appliance from the packaging. Make sure that all protective 

plastic film and coatings are thoroughly removed from all surfaces. 

2. Maintain a distance of 20cm (7 inches) between the unit and walls or 

other objects for ventilation. Increase this distance if the obstacle is a 
heat source. 

3. Set the brakes on the castors to keep the appliance in position.

Fit Glass Panels 

1. Screw the collars to the rim of the appliance.

2. Slot the two side panels into the collars, with the holes in the glass at 

the top.

3. Screw a grub screw into each collar to secure the panels. 

4. Slot the rear panel into the collars, with the holes in the glass at the top.
5. Screw a grub screw into each collar to secure the panel.
6. Slot the plastic plugs into each of the holes.

7. Screw the brackets to the inside of each pane using the bolt assemblies.

8. Place the top panel onto the brackets, ensuring all holes line up.
9. Insert the plugs and attach the top panel to the brackets with the bolt 

assemblies (see below) .

Operation

Storing Food

To get the best results from your RWA appliance, follow these instructions:

Only store foodstuffs in the appliance when it has reached the correct 
operating temperature.

Do not obstruct the fans inside the appliance.

Turn On

1. Ensure the power switch is set to [O] and turn on at the socket.
2. Switch on the Power [I]. The current temperature within the appliance 

is displayed.

Note: If the unit has been stored in a non-vertical position, 

stand it in an upright position for approximately 12 hours 

before operation. 

RWA Refrigerator or Freezer

Top glass panel

Rear glass panel

Side glass panels x 2

Instruction manual

Collars x 6

Brackets x 7

Grub screws x 7

Screws x 12

Plugs x 14

Gastranorm adaptor bar 

Adjustable feet x 4

Note: Before using the appliance for the first time, clean the 

internal cabinet and shelves with soapy water.

Note: Ensure the hole in the collar for the grub screw faces 

inwards. 

Note: Ensure the screw hole furthest from the edge of the 

panel goes to the back of the appliance.

Note: Ensure the soft end of the grub screw is the end making 

contact with the glass.

Note: Ensure the short end of the bolt assembly is on the 

outside of the panels.

Summary of Contents for VRX1200/330

Page 1: ...Stainless Steel Counter Top Servery Prep Refrigerators Models VRX1200 330 VRX1500 330 VRX1800 330 VRX2000 330 ...

Page 2: ...Contents 1 Installation 1 Fit Glass Panels 1 Operation 1 Storing Food 1 Turn On 1 Control Panel 2 Lock Unlock the Control Panel 2 Enter the Parameter Menu 2 Manual Defrost 3 Cleaning Care Maintenance 3 Cleaning the Condenser 3 Error Messages 4 Electrical Wiring 5 Compliance 5 ...

Page 3: ...ly removed from all surfaces 2 Maintain a distance of 20cm 7 inches between the unit and walls or other objects for ventilation Increase this distance if the obstacle is a heat source 3 Set the brakes on the castors to keep the appliance in position Fit Glass Panels 1 Screw the collars to the rim of the appliance 2 Slot the two side panels into the collars with the holes in the glass at the top 3 ...

Page 4: ...er turning on 0 999 seconds d6 Maximum Temperature Differential Alarm Set an alarm to sound if the temperature inside the appliance exceeds the set operating temperature by a specified amount 0 C 50 C d7 Temperature Differential Alarm Delay Set a delay before the temperature differential alarm is triggered 0 99 minutes d8 Defrost Cycle Time Intervals Set the time between each defrost cycle 1 999 h...

Page 5: ...ription Range 22 Unit of Measurement Set whether the temperature is displayed in Centigrade or Fahrenheit Centigrade 0 or Fahrenheit 1 23 Compressor Operation During Probe Failure Set whether the compressor runs or remains Off during a temperature probe failure Compressor runs 1 Remains Off until fault fixed 0 Runs intermittently with parameters 24 and 25 2 24 Compressor On Duration Set the length...

Page 6: ...r of the appliance The water container is damaged Call RWA agent or qualified Technician The drip tray is overflowing Empty the drip tray The appliance is unusually loud The frame has become loose Check and tighten all nuts and screws The appliance has not been installed in a level or stable position Check installation position and change if necessary ErrorMessage flashing Cause Appliance Response...

Page 7: ... to terminal marked E All RWA appliances must be earthed using a dedicated earthing circuit If in doubt consult a qualified electrician Electrical isolation points must be kept clear of any obstructions In the event of any emergency disconnection being required they must be readily accessible Compliance BUFFALO parts have undergone strict product testing in order to comply with regulatory standard...

Page 8: ......