Anvil VRX1200/330 Manual Download Page 1

Stainless Steel Counter Top Servery/Prep Refrigerators

Models:

VRX1200/330 VRX1500/330 VRX1800/330 VRX2000/330

Summary of Contents for VRX1200/330

Page 1: ...Stainless Steel Counter Top Servery Prep Refrigerators Models VRX1200 330 VRX1500 330 VRX1800 330 VRX2000 330 ...

Page 2: ...Contents 1 Installation 1 Fit Glass Panels 1 Operation 1 Storing Food 1 Turn On 1 Control Panel 2 Lock Unlock the Control Panel 2 Enter the Parameter Menu 2 Manual Defrost 3 Cleaning Care Maintenance 3 Cleaning the Condenser 3 Error Messages 4 Electrical Wiring 5 Compliance 5 ...

Page 3: ...ly removed from all surfaces 2 Maintain a distance of 20cm 7 inches between the unit and walls or other objects for ventilation Increase this distance if the obstacle is a heat source 3 Set the brakes on the castors to keep the appliance in position Fit Glass Panels 1 Screw the collars to the rim of the appliance 2 Slot the two side panels into the collars with the holes in the glass at the top 3 ...

Page 4: ...er turning on 0 999 seconds d6 Maximum Temperature Differential Alarm Set an alarm to sound if the temperature inside the appliance exceeds the set operating temperature by a specified amount 0 C 50 C d7 Temperature Differential Alarm Delay Set a delay before the temperature differential alarm is triggered 0 99 minutes d8 Defrost Cycle Time Intervals Set the time between each defrost cycle 1 999 h...

Page 5: ...ription Range 22 Unit of Measurement Set whether the temperature is displayed in Centigrade or Fahrenheit Centigrade 0 or Fahrenheit 1 23 Compressor Operation During Probe Failure Set whether the compressor runs or remains Off during a temperature probe failure Compressor runs 1 Remains Off until fault fixed 0 Runs intermittently with parameters 24 and 25 2 24 Compressor On Duration Set the length...

Page 6: ...r of the appliance The water container is damaged Call RWA agent or qualified Technician The drip tray is overflowing Empty the drip tray The appliance is unusually loud The frame has become loose Check and tighten all nuts and screws The appliance has not been installed in a level or stable position Check installation position and change if necessary ErrorMessage flashing Cause Appliance Response...

Page 7: ... to terminal marked E All RWA appliances must be earthed using a dedicated earthing circuit If in doubt consult a qualified electrician Electrical isolation points must be kept clear of any obstructions In the event of any emergency disconnection being required they must be readily accessible Compliance BUFFALO parts have undergone strict product testing in order to comply with regulatory standard...

Page 8: ......

Reviews: