THESE INSTRUCTIONS MUST BE FOLLOWED FOR US TO 

GUARANTEE OUR FULL SUPPORT OF YOUR CLAIM FOR 

PROTECTING AGAINST LOSS FROM CONCEALED DAMAGE. 

THE FORM FOR FILING SUCH A CLAIM WILL BE PROVIDED 

BY THE CARRIER.

UNPACKING

Unpack the product and check for any damage incurred during 

transit. This should be reported to the responsible carrier, railway or 

postal authority, and a request for a damage report should be made.

These appliances are intended for use with LPG at a pressure of 

2.8kPa. 

Regulators used with this appliance must comply to SANS 1237 and 

be approved by the LPGASA.  Only regulators certified for operation 

at 2.8kPa must be used on these appliances.  

GENERAL INSTALLATION AND OPERATION INSTRUCTIONS

1. This appliance should only be used in a WELL – VENTILATED   

    ROOM. Adequate ventilation allows for the removal of the      

    products of combustion and allows the entry of replacement air.

2. This appliance has a factory set fixed primary air intake and 

    no adjustment is necessary. No adjustments to jets or air intakes 

    should be undertaken unless carried out by a factory approved 

    agent. 

3. The Installation of appliances may only be carried out by a 

    registered installer and such installations shall comply with the 

    requirements of SANS 10087-1

4. Make sure that all connections are gas tight by brushing with 

    a soapy water or liquid detergent (a gas leak will form bubbles). 

    If bubbles form, close cylinder valve and hand tighten all fittings 

    again. IF BUBBLES STILL FORM, DO NOT USE THE APPLIANCE. 

    Have a dealer check the appliance.

1

14

Summary of Contents for COA3003

Page 1: ...www anvilworld com GAS OVEN RANGE...

Page 2: ...ALL ANVIL EQUIPMENT COMES WITH A ONE YEAR WARRANTY ON COMPONENTS AND DEFECTIVE WORKMANSHIP www anvilworld com...

Page 3: ...ranties expressed or implied statutory or otherwise including without limitations any implied Warranty of Merchantability or fitness for purpose are excluded The Seller shall in no event be liable for...

Page 4: ...L INSTALLATION AND OPERATION INSTRUCTIONS 1 This appliance should only be used in a WELL VENTILATED ROOM Adequate ventilation allows for the removal of the products of combustion and allows the entry...

Page 5: ...in Section 5 above Should the flame light back persistently return the product to your authorized ANVIL repair agent 7 To re light the burner follow the procedure as in paragraph 5 and 6 above 8 Befor...

Page 6: ...DOOR HANDLE NODE 11 CABINET DOOR HANDLE TUBE 12 CABINET DOOR HANDLE TUBE 13 EXTERIOR OVEN DOOR 14 INTERIOR OVEN DOOR 15 7 HINGE COA3004 DOOR HINGE 16 OVEN BOTTOM COVER 17 7 SP COA3004 PIEZZO SPARK PLU...

Page 7: ...or effective heat distribution 6 When preparing meat Always put a sheet pan on the bottom of the oven cavity to catch any spillage 7 DO NOT cover any part of the oven or a sheet pan used as drip tray...

Page 8: ...ng as there is no provision for removal of grease and fat THIS APPLIANCE SHOULD NOT BE CLEANED WITH A WATER JET OR IMMERSED IN WATER CLEAN THE STAINLESS STEEL PARTS WITH WATER AND SOAP AVOID THE USE O...

Page 9: ...aged 5 Only LPG hose that complies with SANS 1156 2 or BS 3212 may be used with this appliance 6 Trouble Shooting A normal flame is blue and may have an orange or yellow tip If the flame is completely...

Page 10: ...ith soapy water If a gas leak persists return the product to your dealer for inspection repair 9 Do not modify the appliance or use it for anything other than what it has been designed 10 During use p...

Reviews: