Problem

Possible Cause

Corrective Action

Unit does not have power.

The power cord is not plugged into the 

appropriate outlet or control box.

Plug power cord into the appropriate outlet.

The unit is plugged into a switched 

 

electrical outlet.

Plug the power cord into an unswitched outlet.

Universal Pulse Controller is inoperable.

Contact your maintenance person or Authorized 

Service Agency.

Transformer is defective.

No water comes out of the 

 

filter system.

Inlet/Outlet Ball Valves closed.

Open the Inlet/Outlet Ball Valves.

System depressurized.

Pressurize system.

Drain Valve is stuck open.

Clean, rebuild, and/or replace the Drain Valve.

Rinse Ball Valve is open.

Close the Rinse Ball Valve.

The system may be in a flush cycle.

Wait for the flush cycle to end.

Inlet Strainer (if installed) is plugged.

Clean or replace Inlet Strainer

Ultra Filter Cartridge is plugged.

Replace Ultra Filter Cartridge.

Carbon Element is plugged.

Replace Carbon Element.

Low water flow comes out of the 

filter system.

See above.

See above.

The inlet water pressure is too low.

Boost the inlet water pressure.

The outlet check valve may be plugged 

or defective.

Clean or replace the outlet check valve 

 

assembly.

The inlet flow restrictor may be plugged.

Clean or replace the inlet flow restrictor.

Water tastes bad.

Carbon Element need replacing.

Replace Carbon Element.

Storage/shipping solution not completely 

rinsed out of the system.

Rinse the system for a longer period of time; 

replace Carbon Element.

Biological growth in pipes.

Sanitize plumbing.

Water condition changed.

Consider installing additional filtration.

Broken capillaries in Ultra Filter 

Cartridge.

Replace Ultra Filter Cartridge.

Flush runs continuously.

Drain Valve stuck open.

Clean, rebuild, or replace the Drain Valve.

Controller sending continuous signals to 

valve.

Replace the controller.

Water splashes at drain during  

flush.

Drain line not positioned properly.

Reposition the end of the drain line.

Drain not capable of handling high flow 

rate.

Clean drain; find alternate drain.

Water leaks at ends of the Ultra 

Filter cartridge after changing 

cartridge.

O-rings are not lubricated.

Lubricate O-rings with food grade lubricant.

O-rings are split, cut, or twisted.

Replace O-rings.

Ultra Filter Housing clamps and hardware 

not properly secured

Tighten Ultra Filter Housing Clamps or replace.

Water leaks from Carbon or TAC 

bowls.

O-rings are not lubricated.

Lubricate O-rings with food grade lubricant.

O-rings are split, cut, or twisted.

Replace O-rings.

Water leaks from system 

 

fitting or connection.

Fitting broken or loose.

Tighten or replace the fitting.

Not enough pipe thread sealant used.

Redo the fitting with the proper amount of 

sealant.

Troubleshooting

Summary of Contents for 9710104

Page 1: ...ied and substantiated by test data Owner s Manual Original Instructions Water Filtration Manufacturing Numbers 9710104 9710105 9710106 9710107 9710111 9710113 9710114 9710115 9710116 9710117 9710118 9710119 9710120 9710128 9710132 VZN 521H VZN 521HC VZN 521H T5 VZN 521HC T5 VZN 541H VZN 541HC VZN 541H T5 VZN 541HC T5 VZN 541V VZN 541VC VZN 541V T5 VZN 541VC T5 VZN 541VE www antunes com CAUTION Rea...

Page 2: ... filtration technology Before Use This manual provides the safety installation and operating procedures for the VZN water filtration system All information contained in this manual should be read prior to installing and operating the system Your VZN system is manufactured from the finest materials available and is assembled to strict quality standards This system has been tested at the factory to ...

Page 3: ...suitably sized booster system outlet pressure 60 psig 100 psig max 414 kPa 690 kPa max be installed WARNING ELECTRICAL SHOCK HAZARD Failure to follow the instructions in this manual could result in serious injury or death DO NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician DO NOT use an extension cord with this unit If th...

Page 4: ...ing solutions insecticides Protect from abrasive material The membranes must be protected from abrasive materials like shavings left in a pipe Abrasive materials in contact with the membrane can cause irreversible damage to the membrane All pipes must be flushed clean before installing the filter All plastic parts of the filter system must be protected from sharp objects like knives sand paper or ...

Page 5: ...on Configuration Kit 0012146 DC Power Supply 100 240 VAC Includes the 4 plug adaptors below US NEMA 1 15 2 pin or NEMA 5 15 3 Pin Euro CEE 7 16 AS NZS 3112 AUS 2 Pin UK BS 1363 NOTE Includes plug adaptors for US Europe Australia and UK NOTE PLUG STYLE MAY VARY US NEMA 1 15 2 PIN or NEMA 5 15 3 PIN EURO CEE 7 16 AS NZS 3112 2 PIN AUS BS 1363 UK UK Replacement Cartridges Model Ultrafilter Carbon TAC...

Page 6: ...re or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Performance Data Sheet Filter Cartridge Capacities Maximum Operating Pressure 100 psig 690 kPa Maximum Operating Temperature 100 F 38 C Minimum Operating Temperature 40 F 4 C Maximum Trans Membrane Pressure 45 PSI 3 1 Bar pH Range 3 10 MWCO 100 kD NSF Certified Rated Serv...

Page 7: ...es and cleans the Ultra Filter membrane by removing any debris collecting on the membrane wall The Drain Valve is only powered during Flush Mode NOTE DO NOT unplug the power cord or turn off the system during Flush Mode If there is a power outage or the system is unplugged water will continue to be filtered but the system will NOT flush This could cause the Ultra Filter to plug prematurely and may...

Page 8: ...O NOT connect the system to a switched electrical outlet Plumbing NOTE The system must be connected to the COLD water line DO NOT connect the system to the hot water line The VZN system uses the following connections System Inlet 3 4 FNPT System Outlet Product Water 3 4 FNPT Drain 3 4 FNPT Rinse Outlet 3 4 Garden Hose or 3 4 FNPT When making a plumbing connection to the system use a back up wrench...

Page 9: ...th heavy duty hardware Mounting Hardware Not Supplied The system is pre assembled to a Back Panel The Back Panel has mounting holes across the bottom portion to secure the bottom of the system to the wall Some of the bottom mounting holes may be obscured Plan your mounting accordingly Follow these steps to secure the Mounting Bracket to the wall and seat the VZN system 1 Use a stud finder and leve...

Page 10: ...s the use of an O Ring sealed union is recommended not supplied When connecting the drain hose pay attention to the following guidelines y y The drain line plumbing must be able support the flow rate whenever the system flushes This flow rate is dependent on the inlet water pressure inlet pipe size and system y y The drain line leading out of the system must be as short as possible and slope downw...

Page 11: ...n The System Inlet has a 3 4 FNPT thread at the Inlet Valve Figure 7 DO NOT overtighten fittings as this could cause the plastic ball valve to crack Use plastic fittings and a pipe thread sealant approved for use on PVC fittings when making connections Filtered Water Permeate Outlet Connection The System Outlet has a 3 4 FNPT thread at the Outlet Valve Figure 7 DO NOT overtighten fittings as this ...

Page 12: ...lution NOTE Ultra Filter Cartridge must be rinsed to drain before use Rinsing to drain removes storage solution and air DO NOT rinse into carbon if present Carbon life and or performance may be affected NOTE Make sure the Carbon Element and TAC Cartridge if present are NOT installed These should only be installed after the Ultra Filter Cartridge has been rinsed NOTE DO NOT consume water used durin...

Page 13: ...the plumbing 14 Close all faucets and taps Rinsing the Carbon Element and TAC Cartridge The Carbon Element and TAC Cartridge MUST be rinsed before using the system the first time and immediately after the Carbon Element or TAC Cartridge have been replaced NOTE Wear the supplied gloves for installation and handling of the Carbon element and TAC cartridge If Installed remove the TAC Cartridge Elemen...

Page 14: ...d Cartridge O rings for nicks or cuts Replace as needed 9 Record the serial number of the new cartridge The cartridge serial number is engraved on one end of the outer tube for example 05K 12013 10 Lubricate all O rings with a food grade silicone lubricant Apply a light coating of lubricant to the inside center tube at both ends of the new cartridge 11 Position the new cartridge into the housing a...

Page 15: ... on the Carbon Element Head Use the Filter Wrench if necessary NOTE DO NOT overtighten the Carbon Element Housing 10 Direct water from the Rinse Ball Valve to a drain NOTE Direct the Rinse Ball Valve to a drain DO NOT use the water resulting from the flush procedure 11 Open the Rinse Ball Valve Turn on the water to the system by slowly opening the Inlet Ball Valve Allow water to flow through the C...

Page 16: ...into place on the TAC Head Use the Filter Wrench if necessary 10 Direct water from the Rinse Ball Valve to drain NOTE DO NOT consume the water used for rinsing the TAC Cartridge 11 Turn on the water to the system by slowly opening the Inlet Ball Valve and allow water to flow through the TAC Cartridge and Housing to clear out trapped air and any fines that may be present 12 To help remove trapped a...

Page 17: ... Figure 13 Universal Pulse Controller Semi Annual Task Check Permeate Tank Air Pre Charge It is recommended the permeate tank air charge be checked every six months Caution Air pre charge should only be checked and adjusted under zero system pressure The system must be depressurized before checking the tank pre charge DO NOT adjust the tank air pre charge with the system under pressure Caution Be ...

Page 18: ...d Clean or replace the inlet flow restrictor Water tastes bad Carbon Element need replacing Replace Carbon Element Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace Carbon Element Biological growth in pipes Sanitize plumbing Water condition changed Consider installing additional filtration Broken capillaries in Ultra Filter Cartr...

Page 19: ...male Connector 3 4 CTS X 3 4 NPS 1 17 2190167 Garden Hose Adaptor 1 Item No Part Description Qty 18 2190210 Adaptor Tube to 1 NPT 1 19 2190210 Fitting 3 4 NPT X 3 4 CTS Stem 1 20 3000116 Retainer Nut 1 4 20 4 21 3000132 Cage Nut 8 32 2 22 4040189 Solenoid Valve 24VDC 3 4 NPT 1 23 7002014 End cap Kit SS Drain 1 24 7002025 End Cap Kit SS Inlet w Regulator 8GPM 9710106 9710107 9710128 ONLY 1 7002024 ...

Page 20: ... 18 2190158 Female Connector 3 4 CTS X 3 4 NPS 1 Item No Part Description Qty 19 2190167 Garden Hose adaptor 3 4 NPT x 3 4 1 20 2190189 Adaptor Tube to 1 NPT 2 21 2190210 Fitting 3 4 MPT X 3 4 CTS Stem JG 1 22 3000116 Retainer Nut 1 4 20 4 23 3000132 Cage Nut 8 32 2 24 4040189 Solenoid Valve NC 24VDC 3 4 NPT 1 25 7002014 End cap Kit SS Drain 1 26 7002025 End Cap Kit SS Inlet w Regulator 8GPM 97101...

Page 21: ... 4 NPT x 3 4 GHT 1 18 2190189 Adaptor Tube to 1 NPT 1 19 2190210 Fitting 3 4 MPT X 3 4 CTS Stem JG 1 20 3000116 Retainer Nut 1 4 20 4 21 3000132 Cage Nut 8 32 ZP STEEL 2 22 4040189 Solenoid Valve NC 24VDC 3 4 NPT 1 23 7002014 End cap Kit SS Drain 1 24 7002024 End Cap Kit SS Inlet w Regulator 15GPM 9710113 9710114 9710132 ONLY 1 7002025 End Cap Kit SS Inlet w Regulator 8GPM 971011 ONLY 1 25 7002015...

Page 22: ...ALE STEM 1 17 2190155 Union Tee 3 4 CTS 2 18 2190158 Female Connector 3 4 CTS X 3 4 NPS 1 19 2190167 Garden Hose adaptor 3 4 NPT x 3 4 GHT 1 20 2190189 Adaptor Tube to 1 NPT 2 21 2190210 Fitting 3 4 MPT X 3 4 CTS Stem JG 1 22 3000116 Retainer Nut 1 4 20 4 23 3000132 Cage Nut 8 32 ZP STEEL 2 24 4040189 Solenoid Valve NC 24VDC 3 4 NPT 1 25 7002014 End Cap Kit SS Drain 1 26 7002024 End Cap Kit SS Inl...

Page 23: ...VZN 500 SERIES 23 P N 1013008 Rev C 11 19 Notes ...

Page 24: ...ntenance calibration or regular adjustments as specified in operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulatio...

Reviews: