FEATURES                                                                                                                                      

1.  Microprocessor Fuel Computer - 

Accurately monitors the 

energy in the battery which take into account battery age, self 
discharge, charge/discharge rate, operating conditions and 
previously experienced charge/discharge cycles. The battery 
constantly “learns” its precise state of charge and remaining 
capacity. This data is automatically transmitted to an InterActive 
charger.

2.  RealTime

®

 ‘LCD’ –

 This exclusive Anton/Bauer feature 

simultaneously displays both the remaining run-time and the 
percentage of remaining battery capacity at all times. No special 
adapters or set up is required. (see complete explanation page 3)

3.  Viewfinder Fuel Gauge Display -

 Cameras which include the 

Anton/Bauer InterActive viewfinder feature connect with the 
batteries “Fuel Computer” to display an accurate “Fuel Gauge” 
of remaining battery capacity in the viewfinder.  Reference your 
camera/camcorders owner’s manual for proper menu settings.

4.  Impac

®

 Case design -

 High impact case construction protects 

the cells from damage.

5.  Gold Mount

®

 Interface -

 The patented Gold Mount connector is 

compatible with all Anton/Bauer mounts and accessories.

6.  Individual Computer Testing –

 All Anton/Bauer batteries are 

individually tested to assure optimum capacity, voltage and 
overall quality.

7.  Deep Sleep Motion Sensor – 

The HyTRON incorporates a 

“Deep Sleep” feature that minimizes the self discharge rate of 
the battery when it is inactive and stored for a period of time 
when not on a charger. See complete explanation page 4.

CHARGING                                                                                                                                             

• 

DO NOT ATTEMPT TO CHARGE THIS BATTERY WITH ANY 
CHARGER OTHER THAN THE ANTON/BAUER INTERACTIVE 
CHARGERS SPECIFIED IN THIS MANUAL.

• 

Allow the battery to reach a STEADY GREEN (LifeSaver) 
mode before using for the first time.  Please read the 
individual charger Owner’s Manual for specific operating 
features.

• 

The battery will be approximately 90% charged when the LED’s 
on the charger indicate FLASHING GREEN. The battery is 
100% charged when the charger indicates STEADY GREEN.  
The battery may be removed from the charger and discharged 
in either condition.

• 

The battery can remain on the charger until just prior to 
being used.

  The LifeSaver maintenance routine keeps the 

battery charged and ready for use.  If the battery will not 
be used for an extended period (more than 60 days) see 
“Operating Guidelines” on page 4.

For best results this battery should be used or returned to the 
InterActive charger within 48 hours of being removed from the 
charger.  

Note: On some older chargers it may be necessary to install the 
battery on charger, wait one (1) minute, then remove battery and 
reinstall.  This procedure may need to be repeated more than once 
to “wake up” a low voltage battery.

Summary of Contents for Hytron 100

Page 1: ...HyTRON Nickel Metal Hydride Battery Owner s Manual 7595 0424 Revision A ...

Page 2: ...TABLE OF CONTENTS 1 IMPORTANT INTRODUCTION 2 FEATURES CHARGING 3 BATTERY DISPLAY 4 OPERATING GUIDELINES 5 SERVICE PRECAUTIONS SPECIFICATIONS CHARGE TIMES 6 WARRANTY ...

Page 3: ...date software or firmware available separately depending on model to effectively address new battery systems This upward and downward compatibility allows Anton Bauer to introduce new high performance cell technologies safely and seamlessly into existing inventories The HyTRON battery will automatically identify itself to the InterActive charger activating the proper charge routine s necessary to ...

Page 4: ...ltage and overall quality 7 Deep Sleep Motion Sensor The HyTRON incorporates a Deep Sleep feature that minimizes the self discharge rate of the battery when it is inactive and stored for a period of time when not on a charger See complete explanation page 4 CHARGING DO NOT ATTEMPT TO CHARGE THIS BATTERY WITH ANY CHARGER OTHER THAN THE ANTON BAUER INTERACTIVE CHARGERS SPECIFIED IN THIS MANUAL Allow...

Page 5: ...flash until the battery is returned to a charger 9 If the battery voltage drops below the Fuel Gauge cut out circuit voltage 10 0 to 10 8 VDC the Fuel Gauge will be disabled and the LCD will go blank until the battery is returned to a charger Anton Bauer Logic Series batteries feature the RealTime LCD providing on the fly remaining run time estimates in 15 minute increments as well as simultaneous...

Page 6: ...on Never leave a battery operated device unattended while it is running a Discharging the battery for diagnostic purposes should only be performed on an occasional basis once every 6 8 weeks at most Unnecessary discharging only detracts from overall life b Routine use of a battery at discharge rates greater than the battery rating e g 150 watts maximum 75 watts or less for lighting load can reduce...

Page 7: ... one cell having reached end of life UNDER NO CIRCUMSTANCES attempt to recondition this battery by repeated charging and discharging 4 This battery contains specialized electronic circuits which are designed to protect the NiMH cells from overcharge over discharge and overcurrent Redundant protection devices are designed to operate if the battery voltage is abnormally high or low and if the temper...

Page 8: ...g charges to and from authorized facility THIS WARRANTY DOES NOT APPLY TO AND IS VOID IN THE CASE OF DEFECTS OR DAMAGE RESULTING FROM ACCIDENTS DISASTER NEGLECT MISUSE IMPROPER INSTALLATION IMPROPER OR UNAUTHORIZED SERVICE OR MAINTENANCE UNAUTHORIZED REPLACEMENT PARTS OR ATTACHMENTS OR DYSFUNCTION OR MALFUNCTION OF OR CAUSED BY ANY OTHER PRODUCT OR DEVICE Misuse includes any use of the Product in ...

Page 9: ...ould always be choices It makes it easier to recognize the best Lexan is a registered trademark of G E Company Corp Cordura is a registered trademark of E I duPont de Nemours Due to continuing product development all specifications and prices are subject to change without prior notification Anton Bauer Inc World Headquarters 14 Progress Drive Shelton Connecticut 06484 USA 203 929 1100 800 541 1667...

Reviews: