![Anton/Bauer Hytron 100 Owner'S Manual Download Page 4](http://html.mh-extra.com/html/anton-bauer/hytron-100/hytron-100_owners-manual_2948082004.webp)
2
FEATURES
1. Microprocessor Fuel Computer -
Accurately monitors the
energy in the battery which take into account battery age, self
discharge, charge/discharge rate, operating conditions and
previously experienced charge/discharge cycles. The battery
constantly “learns” its precise state of charge and remaining
capacity. This data is automatically transmitted to an InterActive
charger.
2. RealTime
®
‘LCD’ –
This exclusive Anton/Bauer feature
simultaneously displays both the remaining run-time and the
percentage of remaining battery capacity at all times. No special
adapters or set up is required. (see complete explanation page 3)
3. Viewfinder Fuel Gauge Display -
Cameras which include the
Anton/Bauer InterActive viewfinder feature connect with the
batteries “Fuel Computer” to display an accurate “Fuel Gauge”
of remaining battery capacity in the viewfinder. Reference your
camera/camcorders owner’s manual for proper menu settings.
4. Impac
®
Case design -
High impact case construction protects
the cells from damage.
5. Gold Mount
®
Interface -
The patented Gold Mount connector is
compatible with all Anton/Bauer mounts and accessories.
6. Individual Computer Testing –
All Anton/Bauer batteries are
individually tested to assure optimum capacity, voltage and
overall quality.
7. Deep Sleep Motion Sensor –
The HyTRON incorporates a
“Deep Sleep” feature that minimizes the self discharge rate of
the battery when it is inactive and stored for a period of time
when not on a charger. See complete explanation page 4.
CHARGING
•
DO NOT ATTEMPT TO CHARGE THIS BATTERY WITH ANY
CHARGER OTHER THAN THE ANTON/BAUER INTERACTIVE
CHARGERS SPECIFIED IN THIS MANUAL.
•
Allow the battery to reach a STEADY GREEN (LifeSaver)
mode before using for the first time. Please read the
individual charger Owner’s Manual for specific operating
features.
•
The battery will be approximately 90% charged when the LED’s
on the charger indicate FLASHING GREEN. The battery is
100% charged when the charger indicates STEADY GREEN.
The battery may be removed from the charger and discharged
in either condition.
•
The battery can remain on the charger until just prior to
being used.
The LifeSaver maintenance routine keeps the
battery charged and ready for use. If the battery will not
be used for an extended period (more than 60 days) see
“Operating Guidelines” on page 4.
For best results this battery should be used or returned to the
InterActive charger within 48 hours of being removed from the
charger.
Note: On some older chargers it may be necessary to install the
battery on charger, wait one (1) minute, then remove battery and
reinstall. This procedure may need to be repeated more than once
to “wake up” a low voltage battery.