Anton/Bauer Dionic 26V LP4 Gold Mount Plus User Manual Download Page 10

8

Self-Test

Upon applying AC mains power, the charger will initiate a brief 

self-test mode. Self-test mode is complete when the charger LED 

indicates battery information on the position being used.

Charging

As with all Anton/Bauer chargers, charging with a 26V LP4 Gold 

Mount Plus Charger is fully automatic. Mount any applicable battery 

to any open position on the charger and the 26V LP4 Gold Mount 

Plus Charger will automatically determine the appropriate charge 

routine and execute it.

In some cases a battery may be discharged to a very low 

voltage level causing the battery to be unrecognizable to the 

charger when first attached.

1

2

3

Three Stage Charging Methodology 

In general, the 26V LP4 Gold Mount Plus Charger will deliver a three 

stage charge routine to each battery.

Stage One

 will deliver a high rate charge matched to the 

capabilities of the battery (typically a one or two hour rate, 

depending on battery type). During this stage, six separate cutoff 

methods are in operation, simultaneously, ensuring the fastest, 

safest charge for that battery.

Stage Two

 charging is a BALANCING or “stabilizing” mode 

which calculates each battery pack type to offset any imbalance 

of the battery’s cells, created by unequal self-discharge or any 

capacity mismatch of the individual cells in the pack. This stage 

can vary in duration from zero to as much as 16 hours, depending 

on the condition of the battery. The Stage Two charge reduces 

current automatically as the battery charges maintaining the cells 

at a safe voltage level. A battery will typically leave Stage Two in 

2-4 hours under average operating conditions.

Stage Three

 charging is the Anton/Bauer exclusive Lifesaver

®

 

maintenance mode. This patented pulse routine keeps batteries 

fully charged, free from self-discharge - indefinitely - without 

damaging heat associated with a so-called “trickle charge”. The 

Stage Three programming monitors the self-discharge of the 

battery, providing charge only when the battery self-discharges to 

about 95% of its capacity.

Anton/Bauer recommends that batteries remain on the 

charger and plugged into AC mains power for best results. 

The Lifesaver mode will keep them 100% charged. 

 

Removal of AC Mains Power

If AC mains power is removed, it is highly recommended that the 

batteries are removed from the charger, thus avoiding any additional 

self-discharge of the battery.

Operation

Summary of Contents for Dionic 26V LP4 Gold Mount Plus

Page 1: ...Mobile Power Perfected User Guide Part No 7595 0473 www antonbauer com EN Dionic 26V LP4 Gold Mount Plus 26V 14V Battery Charger Dionic 26V LP4 Gold Mount Plus Battery Charger ...

Page 2: ...ch revisions or changes Changes will be incorporated in new versions of the publication We are making every effort to ensure that our manuals are updated on a regular basis to reflect changes to the product specifications and features Should this manual not contain information on the core functionality of your product please let us know You may be able to access the latest revision of this manual ...

Page 3: ...Third Party Gold Mount Compatibility 5 Components and Connections 6 Wi Fi Capability 6 Mini USB Port 6 AC Mains Power 6 Attaching a Battery to the Charger 7 To Release the Battery 7 Operation 8 Self Test 8 Three Stage Charging Methodology 8 Removal of AC Mains Power 8 LED Indicators 9 Technical Specifications 10 After Sales Support 11 General Notices 12 Warranty 14 ...

Page 4: ...ortable power system addressing both Gold Mount and V mount configurations The technology advancements of this charger deliver the features and performance of several essential power products in one economic and portable package while reducing power consumption Electrical Connection WARNING Risk of electric shock Do not remove cover no user servicable parts inside the product WARNING Risk of elect...

Page 5: ...r to the product technical specifications for the operating limits for the product CAUTION Slots and openings are intended for ventilation purposes to ensure reliable operation of the product andprotect it from overheating Do not block or cover any slots and openings WARNING Protect the product from water moisture and dust The presence of electricity near water can be dangerous WARNING Charger mus...

Page 6: ...ecautions and handling instructions are contained in this user guide and should be strictly adhered to for safe and reliable operation Contact Anton Bauer Customer Support Group with any questions regarding this product Digital G90 Digital G150 Digital G190 Digital V90 Digital V150 Digital V190 DIONIC HC DIONIC HCX DIONIC HD HyTRON 100 HyTRON 140 CINE G90 CINE G150 CINE V90 CINE V150 Anton Bauer B...

Page 7: ...rotocol to maximize the life cycle of our batteries This protocol is not always compatible with competitive batteries Therefore we cannot guarantee the Dionic 26V LP4 Charger can charge 3rd party batteries to 100 full capacity The list below does not constitute all of the potential compatible batteries therefore it is the recommendation of Vitec Production Solutions to utilize Anton Bauer batterie...

Page 8: ...they are released Mini USB Port Located at the back this port is used to upgrade the firmware of the 26V LP4 Gold Mount Plus Charger For information please contact the Anton Bauer Customer Support Group AC Mains Power The AC Mains power connector is located on the rear of the charger USB Connector for Flash Drive Port Located at the back this port can also be used to upgrade the firmware of the 26...

Page 9: ...r 1 Slide the battery onto the adaptor ensuring the Gold Mount T stud is aligned in the corresponding slots 2 The battery is fully engaged when the latch makes an audible click Components and Connections To Release the Battery 1 Depress the latch and hold 2 Slide the battery off the connector 1 2 ...

Page 10: ... BALANCING or stabilizing mode which calculates each battery pack type to offset any imbalance of the battery s cells created by unequal self discharge or any capacity mismatch of the individual cells in the pack This stage can vary in duration from zero to as much as 16 hours depending on the condition of the battery The Stage Two charge reduces current automatically as the battery charges mainta...

Page 11: ...ge status of the battery LED Description Alternating Red and Green Evaluate Flashing Red Stage One Flashing Green Stage Two Solid Green Stage Three Liversaver Mode The best battery to use is signified by a more intensley illuminated solid Green Solid Red Hold If persistent please contact the Anton Bauer Customer Support Group Solid Green and Red Error Mode Charger Error ...

Page 12: ...nal Battery Charge Times Battery Approx Charge Time Digital G90 2 5 Hrs Digital G150 3 5 Hrs Digital G190 4 5 Hrs Dionic HC 2 5 Hrs Dionic HCX 3 0 Hrs Dionic HD 4 5 Hrs HyTRON 100 3 5 Hrs HyTRON 140 4 0 Hrs Titon G 90 2 5 Hrs Titon G 150 2 8 Hrs Titon SL G 150 3 3 Hrs Titon SL G 240 4 9 Hrs Dionic XT G 90 2 5 Hrs Dionic XT G 150 3 5 Hrs Dionic 26V GM 98 1 3 Hrs Dionic 26V GM 240 3 2 Hrs In some ca...

Page 13: ... experience with our products will be even more positive and productive with strong effective support to back them up Vitec Production Solutions s Service Centers are there to provide technical support for customers and partners via telephone or email For more information including complete contact details please go to vitecsupport com ...

Page 14: ...f not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense This equipment has been approved by one or more agencies All changes and or modifications not expre...

Page 15: ...ce of any claim under this warranty shall be delivered to Anton Bauer during the period of the warranty and the Product shall be returned with its packaging promptly at your expense to an Anton Bauer Customer Support Center or to the address above Upon receipt of the Product and a record of your compliance with the conditions of this warranty Anton Bauer will repair or replace the Product and retu...

Page 16: ...y not apply to you This warranty gives you specific legal rights and you may have other legal rights which may vary from state to state Use of unauthorized equipment in conjunction with Anton Bauer products constitutes misuse under our warranties and may limit or void those warranties Anton Bauer does not authorize condone recommend or otherwise assume any liability or responsibility resulting fro...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...Publication Part No 7595 0473 Mobile Power Perfected www antonbauer com ...

Reviews: