Anthem PVA 7 Operating Manual Download Page 2

DEAR VALUED CUSTOMER,

We at Sonic Frontiers International hope you will derive many years of listening pleasure from your new 7 channel amplifier,

the Anthem PVA 7 Amplifier. This Operating Manual contains important information regarding the operation and care of the

PVA 7 Amplifier.  Be sure to read this manual carefully and follow these instructions in order to keep your unit performing

and sounding its best. Please contact Sonic Frontiers if you have any questions, a Customer Service Representative will be

pleased to assist you.

HAPPY LISTENING!

READ THIS SECTION CAREFULLY BEFORE PROCEEDING!

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user of 

uninsulated “dangerous voltage” within the products enclosure, of sufficient magnitude to constitute a risk of

electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important

operation and maintenance (servicing) instructions in the literature accompanying the amplifier.

Before operating your PVA 7 Amplifier, read and follow all instructions and warnings! Retain these instructions for future

reference.

CAUTION!

To protect against electrical shock and risk of fire do not expose to rain or moisture and do not use amplifier near sinks,

showers, bathtubs, swimming pools, saunas, in wet basements or near any source of water. Always unplug before

cleaning, and use a damp soft cloth.

To protect against electrical shock do not remove the amplifier cover. There are no user serviceable parts inside. If the unit

has been dropped, damaged, exposed to water or does not operate normally, it must be serviced. Refer any servicing to

your Authorized Anthem Dealer, who will return the product to Sonic Frontiers International.

CAUTION!

This amplifier has a polarized electrical plug. To protect against electrical shock do not use with any receptacle, extension cord

or any other outlet unless the metal arms of the plug can be fully inserted so that they are not exposed.

Use only with the AC voltage rating indicated on the rear panel. Do not overload outlets or extension cords, as this can

result in a risk of fire or electrical shock. Install so that the power cord will not get damaged over time. Unplug the amplifier

when not using it for an extended period of time to prevent damage due to lightning and power surges.

To protect against risk of fire and electric shock, do not allow any liquids or objects to penetrate the amplifier enclosure.

2

P V A   7   A M P L I F I E R

Summary of Contents for PVA 7

Page 1: ...P V A 7 A M P L I F I E R O P E R A T I N G M A N U A L ...

Page 2: ...ure reference CAUTION To protect against electrical shock and risk of fire do not expose to rain or moisture and do not use amplifier near sinks showers bathtubs swimming pools saunas in wet basements or near any source of water Always unplug before cleaning and use a damp soft cloth To protect against electrical shock do not remove the amplifier cover There are no user serviceable parts inside If...

Page 3: ...TO or TRIGGER mode the LED will be lit red until the amplifier receives a music signal auto or a trigger voltage trigger at which point the LED will turn green B POWER BUTTON When in the ON position button depressed AC voltage is applied and the 7 channel circuitry receives high voltage power from the DC power supplies When in the OFF position not depressed the amp is not receiving AC power and is...

Page 4: ...rns the amplifier on whenever there is an input signal on any one of the channels If no input signal is sensed after a period of time the amplifier will switch off automatically E DETACHABLE AC POWER CORD SOCKET Plug the Detachable Power Cord into this socket The PVA 7 Amplifier is factory built for the correct operating voltage for the area in which it is sold see shipping box for voltage setting...

Page 5: ...iate ON MODE for your PVA 7 Amplifier If TRIGGER mode is selected connect a standard 3 5mm Mini Plug trigger cable between your PVA 7 Amplifier and the upstream control component such as the Anthem AVM 20 Connect the Detachable Power Cord to the AC Power Cord Socket E in figure 2 Plug your amplifier into the AC power source After you ensure your preamp or SSP has the volume turned down or muted yo...

Page 6: ... W 140 W 300 W HEADROOM 1 25 dB 8 Ω 2 13 dB 4 Ω POWER BANDWIDTH 10 Hz 80 kHz 125 W 8 Ω FREQUENCY RESPONSE 20 Hz 20 kHz 0 20 dB 5 Hz 100 kHz 2 5 dB THD N 0 002 1 kHz 0 03 20 kHz 125 W into 8 Ω INPUT SENSITIVITY 1 12 VRMS for 125 W into 8 Ω INPUT IMPEDANCE 10k Ω DAMPING FACTOR 200 1 kHz ref 8 Ω S N RATIO 122 dB A weighted ref 125 W CHANNEL SEPARATION 65 dB 100 Hz 10 kHz VOLTAGE GAIN 29 dB SLEW RATE ...

Page 7: ... the responsibility of the dealer distributor to determine the nature of the problem and arrange for either the appropriate replacement parts or the return of the product to the factory All other warranties or conditions either written or implied are void Sonic Frontiers International reserves the right to improve the design of any product without assuming any obligation to modify any product prev...

Page 8: ... S S A U G A O N T A R I O C A N A D A L 5 L 5 Y 7 T E L 9 0 5 8 2 8 4 5 7 5 F A X 9 0 5 8 2 8 4 5 8 5 S o n i c F r o n t i e r s c a n b e r e a c h e d 9 0 0 a m t o 5 0 0 p m E S T o r 2 4 h o u r s a d a y b y f a c s i m i l e E M A I L S F I s o n i c f r o n t i e r s c o m W E B S I T E h t t p w w w s o n i c f r o n t i e r s c o m 23 07 01 ...