Anthem MCA 225 Operating Manual Download Page 8

2

2.1

  INPUT CONNECTIONS

Balanced XLR connection offers the highest transmission quality, particularly over long 
cable lengths, because it rejects noise and hum pickup. If your preamplifier does not 
have XLR outputs, use the RCA inputs.

Do not use “RCA-compatible” connectors that have a hollow center pin with a hole 
at its tip. They can damage the amplifier’s RCA jack internally while being inserted.

2.2

  SPEAKER CONNECTIONS

Depending on the level of the input signal, the voltage at the outputs can be high 
enough to cause electric shock – be sure that power is turned off when connecting or 

disconnecting anything. As well, be sure that the speakers are rated for 
use with this amplifier – an overdriven speaker can pose a fire hazard.

Connect the red (+) connection on the speaker to the red (+) binding post 
on the amplifier, and the black (–) connection on the speaker to the black 
(–) binding post on the amplifier using cable that is insulated to handle 

the maximum output of the amplifier. Do not overtighten the binding posts as this may 
cause damage. The binding post pair accepts a connection from one speaker. 

2.3

  ON MODES

With the three-way switch located on the rear panel, you can set the way the amplifier is 
turned on and off. To use Trigger-On, connect a standard 3.5mm (1/8”) mono mini plug 
cable between the amplifier and the preamplifier or control component. Once all other 
connections are made, connect the power cord to the amplifier and then the wall outlet.

Manual-On:

 

When in this position, the amplifier is turned on/off via the power button on the front 
panel.

Trigger-On:

 

This feature allows the amplifier to be turned on or off remotely via the trigger. The 
3.5mm (1/8”) mini-jack IN receives power (5-24 volts DC) from an upstream component 
or system controller. The same trigger signal can be linked to trigger inputs on other 
units through the OUT jack. When using Trigger mode, leave the front power button in 
the “on” position.

Auto-On:

 

This feature also eliminates the need to manually operate the power button. Auto-On 
turns the amplifier on when it senses an input signal, and switches off approximately 
20 minutes after input signal stops. When using Auto-On mode, leave the front power 
button in the “on” position..

C O N N E C T I O N S   A N D   O P E R A T I O N

Summary of Contents for MCA 225

Page 1: ...OPERATING MANUAL MCA 525 325 225 P O W E R A M P L I F I E R S...

Page 2: ...ided for your safety When the provided plug does not t into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particul...

Page 3: ...e hot CAUTION These servicing instructions are for use by quali ed service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating i...

Page 4: ...ns given below IMPORTANT DO NOT make any connection to the larger terminal which is marked with the letter E or by the safety earth symbol or colored GREEN or GREEN AND YELLOW The wires in the mains l...

Page 5: ...that only the product falls under the WEEE directive When disposing of packaging and other shipping material we encourage you to recycle through the normal channels INFORMATION ABOUT COLLECTION AND D...

Page 6: ...1 Before Making Connections 1 1 2 In Use Notices 1 1 3 Rack Mounting CONNECTIONS AND OPERATION 2 2 1 Input Connections 2 2 2 Speaker Connections 2 2 3 On Modes 3 2 4 Front Panel 4 2 5 Rear Panel 5 MEA...

Page 7: ...t panel power button does not disconnect the product from the AC line Ensure that the power cord remains readily accessible at all times To connect power only use the supplied double insulated power c...

Page 8: ...se damage The binding post pair accepts a connection from one speaker 2 3 ON MODES With the three way switch located on the rear panel you can set the way the ampli er is turned on and off To use Trig...

Page 9: ...touch other wires or ampli er chassis or any piece of metal Slow ashing more than 1 second thermal protection Allow ampli er to cool and ensure that ventilation is adequate In an over temperature cond...

Page 10: ...PUT M C A 525 AC INPUT 120V 60Hz 1200W FUSES ON MODE TRIGGER T10AH 5 24V AC DC 2011 65 EC SERIAL NUMBER Designed Engineered and Made in Canada by Paradigm Electronics Inc TRIGGER ONLY MANUAL ON AUTO O...

Page 11: ...5 Vrms Voltage Gain 29 dB This product operates from a single phase AC power source that supplies 108V 132V at a frequency of 60 Hz for the 120V version and 198V 264V at a frequency of 50 60 Hz for th...

Page 12: ...appropriate action Alternatively follow the procedure below for factory service A Return Authorization RA number must be obtained from Anthem Technical Support before a product can be shipped to Anthe...

Page 13: ...1 905 564 1994 8 30 am 5 00 pm M F ET www anthemAV com MAN0118 2016 01 15...

Page 14: ...mproved Advanced Load Monitoring system 8 bipolar output devices per channel for less stress on each device Less than 2 watts standby power consumption Crafted In Canada MCA teams up perfectly with an...

Page 15: ...the while eliminating the need for internal fuses ALM is not in the signal path so it never gets in the way Instead ALM engages instantly but only in the most extreme circumstances to protect your amp...

Page 16: ...quality sound from top to bottom of the frequency spectrum Stable As A Rock Our amplifiers are incredibly stable into difficult low impedance speaker loads making these superb sounding dynamos reliabl...

Page 17: ...Channel Separation 100 Hz to 10 kHz 65 dB Input Impedance RCA XLR 10 k 15 k Input Sensitivity 225 W into 8 1 5 Vrms Voltage Gain 29 dB This product operates from a single phase AC power source that su...

Reviews: