![ANTEK FU3AM-03 Operating Manual Download Page 23](http://html1.mh-extra.com/html/antek/fu3am-03/fu3am-03_operating-manual_2947485023.webp)
Chapter 6: SERVICE-INFORMATION
Operating Manual FU3AM-03
Page 23 of 30
6. Service information
6.1 Summary of parameters
No.
Parameter
Explanation
30
Mode
31
switching fre-
quency
Cycle frequency output stage
32
U-0
Output voltage
33
U-50
Voltage at 50Hz
34
f-nom
Output frequency with max. set value specification
35
Offset
Offset set value
36
Mult. of speed
set value
Multiplier for set value
37
N1
fixed set value 1
38
N2
fixed set value 2
39
N3
fixed set value 3
40
tH
Set value ramp during acceleration
41
tR
Set value ramp during braking
42
n-nom
Nominal speed for speed controller mode
43
number of poles Number of motor poles
44
Number of gra-
dations
Number of gradations for pulse generator
45
t-n-act
Speed actual value filter
46
KPn
KP- speed controller
47
KIn
KI- speed controller
48
regulator range Influence of speed controller
49
max difference
Threshold nom.-act. -monitoring
50
t-difference
Delay signal contact Nom.-Act monitoring
51
I-peak
Current peak
52
I-Cont.
Continuous current
53
t-I-act
actual value filter
54
t-I-red
Transit time current threshold
55
autoreset
0=no automatic reset
57
Temp. Mot.
threshold motor temperature
58
Mot.-Sens.
Temperature sensor motor
65
source set value Set value specification over analogue voltage/fixed set value or over
digital inputs SW_0 … SW_9