background image

Antec, Inc.

47900 Fremont Blvd.

Fremont, CA 94538

USA

tel: 510-770-1200

fax: 510-770-1288

Antec Europe B.V.

Stuttgartstraat 12

3047 AS Rotterdam

The Netherlands

tel: +31 (0) 10 462-2060

fax: +31 (0) 10 437-1752

Customer Support:

US & Canada

1-800-22ANTEC

[email protected]

Europe

+31 (0) 10 462-2060

[email protected]

www.antec.com

© Copyright 2007 Antec, Inc. All rights reserved.

All trademarks are the property of their respective owners.

Reproduction in whole or in part without written permission is prohibited.

Printed in China.

Summary of Contents for TruePower Quattro TPQ-1000

Page 1: ...TruePower Quattro User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario পᡅ䂀ᯢ ...

Page 2: ...ut still allow for superior cooling capabilities as loads increase With its high efficiency and low heat generation the power supply utilizes a smaller fan The exhaust fan rotates slowly and quietly to blow hot air out of the power supply speeding up as heat increases The TruePower Quattro PSU features Universal Input which allows you to connect the power supply to any AC power source between 100 ...

Page 3: ...s 2 Molex and Floppy connector w cable Includes three Molex connectors and one floppy connector 1 Molex connector w cable Includes three Molex connectors 1 Serial ATA connector w cable Includes two Serial ATA connectors 2 Serial ATA connector w cable Includes three Serial ATA connectors 2 PCI Express connector w cable Includes one PCI Express connector Table 1 x1 x3 x2 x3 x3 x1 ...

Page 4: ...h the four screws provided 2 Connect the 24 pin Main Power Connector to your motherboard If your motherboard uses a 20 pin connector detach the 4 pin attachment on the 24 pin connector Note The detachable 4 pin section cannot be used in place of a 4 pin 12V connector 1 2 ...

Page 5: ...lease also refer to your motherboard user guide for any special instructions 4 Connect the cables from cable pack to the socket on the power supply as needed 5 Connect the AC power cord to the power supply AC inlet and turn the switch to I position 3a 3b 5 4 or ...

Page 6: ...rrent power supplies 80 PLUS certified power supplies Achieve energy savings up to 70 55 Euro over the life of a desktop computer Reduce a room s cooling load increasing comfort and saving up to 30 Increase computer system reliability and save on maintenance costs by as much as 40 Minimize the need for noisy fans creating a quieter environment Save on construction saves hundreds of dollars in elec...

Page 7: ...0 10 462 2060 fax 31 0 10 437 1752 Customer Support US Canada 1 800 22ANTEC customersupport antec com Europe 31 0 10 462 2060 europe techsupport antec com www antec com Copyright 2007 Antec Inc All rights reserved All trademarks are the property of their respective owners Reproduction in whole or in part without written permission is prohibited Printed in China ...

Reviews: