5
important that the fog does not shoot directly at any one’s face. Whatever installation method
you choose, do not allow the unit to have more than a 25 degree angle of inclination.
Z-1200II Description
Note:
If you experience low output, pump noise or no output at all, unplug immediately. Check fluid level, the
external fuse, remote control connection and power from the wall. If all of the above appears to be O.K.,
plug the unit in again. If fog does not come out after holding the remote button down for 30 seconds,
check the hose attached to the tank to make sure there is fluid going through the hose. If you are unable
to determine the cause of the problem, do not simply continue pushing the remote button, as this may
damage the unit. Return the machine to your ANTARI dealer.
Z-1200II Technical Specifications
- Input voltage
- Rated power
- Warm-up time
- Fluid consumption
- Fluid tank capacity
- Compatible fluid
- Ambient temp. range
- Output
- Control
- DMX channels
- Connection
- Optional accessories
- Dimension
- Weight
US model : AC100-120V, 50 / 60Hz 10.5A
EU model : AC 220-240V, 50 / 60Hz 5.5A
1200W
10 minutes (approx.)
72 ml/min
2.5l (0.66gal)
Antari FLG Heavy Fog Fluid
Antari FLR Light Fog Fluid
0 °C - 40 °C (32 °F-104 °F)
18,000 ft
3
/min (510 m
3
/min)
DMX512, Manual, Timer
Wireless (Optional)
1 channel
XLR 3-pin (DMX)
Z-9 Wireless Remote
L458 W243 H251 mm
(L18.03 W9.57 H9.88 inch)
10.9 kg (24.03 lbs)